The electric gate controller of the electric gate controller is used to operate

Updated on Financial 2024-05-18
7 answers
  1. Anonymous users2024-02-10

    1. Installation: Professionals should be correctly installed in accordance with the requirements of the manual. The power cord and motor power line should be selected with a wire diameter of not less than the copper core sheathed cable, and other control lines should be selected with a copper core cable with a wire cross-section not less than.

    The power live wire should be connected to the L end of the controller, and the neutral wire should be connected to the n end of the controller. The in-machine safety should use a 5 20mm 6A fast fuse, and it is strictly forbidden to use the in-machine safety as a direct short circuit. The door head motor of the electric door should be connected to the P1 terminal strip in the machine.

    The alarm should be connected to the P4 terminal strip in the machine. Other basic control cables should be connected to the P2 terminal strip in the machine. When installing the wiring, it should be connected correctly with reference to the wiring diagram attached to the product.

    In particular, it is important not to connect the low-voltage control wire to the high-voltage terminal or the high-voltage control wire to the low-voltage terminal. In addition to the matters specified in this product, the wiring and installation of the controller shall comply with the relevant provisions of the electrical safety operation regulations. The installation position of the controller is selected according to the specific situation of the user, and the appropriate position is selected to hang on the wall of the five magnetic field interference.

    The installation height should not be less than the ground. The cable that leads out should be firmly fixed along the wall. Before powering on, all installation work should be fully inspected, and the power test machine can be sent only after it is confirmed.

    The probe is mounted outdoors at an appropriate height and the angle can be adjusted.

    2. Operation: manual control of door body switch:

    After the power is turned on, the middle of the controller's digital display window should display " " " is the standby state of the controller at this time. The four buttons on the controller panel are "Close Door", "Stop", "Open Door", and "Alarm". When the "Open" or "Close" key is pressed, the display window should display "H" or "E", respectively.

    At this time, the door operator drags the door body to move, and the controller has a low-frequency signal sound at this time. When the door body is moving, when the limit switch is in action or the automatic delay action, the door body automatically stops moving, and the low-frequency signal automatically stops sounding. When changing from opening the door to closing the door, or from the door to the door, you must press the stop button to change.

    Remote control of door body switch:

    The "A" button of the remote control corresponds to the "Open Door" of the manual switch, the "B" key corresponds to the "Stop" of the manual switch, the "C" key corresponds to the "Close Door" of the manual switch, and the "D" key corresponds to the "Alarm" function of the manual switch. When in use, press the corresponding function key of the remote control for about 1 time, the door body will move or stop according to the established function, and its operation process is the same as manual control. The control distance of the remote control has a certain influence on the strength of the electromagnetic field on the spot, the battery voltage of the remote control transmitter, the change of climate and other factors, which is a normal phenomenon, and the use of tie rod antenna can appropriately increase the control distance.

    Alarm function setting:

    Press the "Alarm" button for manual control or the "D" button for remote control to set the alarm status. This key is a repeat key, that is, the setting and disarming of the alarm are generated alternately. When the alarm status is set, the window displays "Day".

    When the alarm status is dismissed, the window will be displayed as " "When the alarm appears, the controller will have a high-frequency audible signal to emit. When the door body is started (switch), the alarm state is automatically released. When the door body is moving, the alarm can still be set, but the alarm function is in a suspended state, and the alarm state is automatically restored when the door body movement stops.

  2. Anonymous users2024-02-09

    When the door is opened, the door does not open back and forth in place.

  3. Anonymous users2024-02-08

    1. There is a switch that can be debugged, clockwise fast, counterclockwise slow, and manual debugging is OK.

    2. The gain adjustment of the amplification circuit, the position of this knob is around the original amplification circuit. This knob is generally not adjusted, it is used by the manufacturer to correct the discrete dispersion of the sensitivity output of the microwave module. The gain adjustment knob is not as easy to operate as the sensitivity adjustment knob compared to the sensitivity adjustment knob.

    3. The action area of the sensor can be adjusted by adjusting the pitch and horizontal angle of the microwave module.

    4. The sensitivity knob is adjusted, and the sensitivity is determined by adjusting the MCU digital-to-analog conversion threshold. Different versions of the sensor have different positions, see the random instructions for details. Laughs.

    5. Among them, the sensitivity and microwave antenna elevation angle adjustment is a more concise and intuitive method, and at the same time, it is necessary to pay attention to the adjustment of the antenna angle when the number of spikes must be carried out after power failure, some Panasonic automatic induction door sensors are damaged because they touch the electronic circuit board when adjusting the elevation angle of the antenna, causing a short circuit, and then burning out the electronic components and damage.

    6. Adjustment of the sensitivity knob of the automatic sensing door: determine the sensitivity by adjusting the MCU digital-to-analog conversion threshold. The action area of the sensor is adjusted by adjusting the pitch and horizontal angle of the microwave module of the automatic sensing door.

  4. Anonymous users2024-02-07

    Common faults Troubleshooting method 1 The indicator light is not lit after power-on, and the door body cannot be started 1, check the power supply 2, check the fuse in the machine 3, check the control cable 4, check the motor and starting capacitor 5, check whether the P5 socket contact in the machine is good 6, the clutch of the head is not disengaged 2 The movement of the door body can not be limited 1, check whether the reed switch or magnet is normal 2, check whether the control circuit is open 3, whether the anti-collision sensor switch is normal 4, whether the delay stop setting is correct and adjust the dial switch to adjust the delay setting 3 The remote control does not work or is not sensitive 1. Check whether the transmitter battery voltage is lower than 10V 2. Check whether there is electromagnetic interference nearby 3. Whether the remote control is damp and whether there is dirt in the button 4. Check whether the power supply voltage of the controller is low 4 The alarm function is not normal 1. Whether the controller is set to the alarm state 2. Check the cable connection between the probe and the controller 3. Check the performance of the probe 4. Whether the plug wiring is correct 5 The controller window is not displayed 1. Whether the P5 socket wiring is normal 2. Whether the digital tube is damaged 6 The sound signal is abnormal 1. Whether there is an open circuit in the machine 2 Whether the IC or transistor is damaged 3, whether the signal is damaged, you can use the battery to try the sound 7 The fuse blows 1, check whether the fuse capacity is correct 2, whether there is a short circuit in the door head machine, you can get rid of the load of the door machine and then try to determine whether the fault is the door machine or the controller 3, the cable is short-circuited.

  5. Anonymous users2024-02-06

    Relay control circuit for electric retractable doors.

    1. Single-phase motor telescopic door control circuit.

  6. Anonymous users2024-02-05

    The drive of the electric telescopic door is driven by a special motor, the worm gear is decelerated, and there is no manual clutch, and the power failure can be opened and closed manually, and the control system of the telescopic door has a control board, a button switch, and can be equipped with a wireless remote control device according to user needs.

  7. Anonymous users2024-02-04

    1.Check the power supply 2Check the in-flight fuse 3Check the control cable 4Check the motor and starting capacitor.

Related questions
7 answers2024-05-18

The speed can be adjusted by rotating the handlebar, i.e. by hand. >>>More

3 answers2024-05-18

It's a bright day for this chaotic electric car season

23 answers2024-05-18

Nowadays, on the road we can see a lot of electric vehicles coming and going every day, and now, there are many manufacturers that produce electric vehicles, and there are countless brands, so when we buy electric vehicles, which brand of electric vehicles is good, let's take a look at it. >>>More

8 answers2024-05-18

How many volts does the electric tricycle controller supply to the motor with normal voltage.

10 answers2024-05-18

The brake power line is generally used with yellow and green two-color wires, and the brake power off is also divided into high level brakes and low level brakes. >>>More