Why can t people live in tin houses?

Updated on healthy 2024-07-02
3 answers
  1. Anonymous users2024-02-12

    Because the hazards of living in a tin house are:

    One is that it is not ventilated; Very occlusive and prone to breathing difficulties.

    the second is thunder and rain; There will be a danger of lightning strikes.

    Third, the noise is huge; Affects normal dormancy.

    Fourth, it is too hot in summer, after a day of sun exposure, and the iron sheet absorbs heat, people are easy to sweat, and a lot of sweating will lead to prostration. Fifth, it is too cold in winter; Moreover, the iron is magnetic and easily absorbs electromagnetic waves.

    It is also extremely damaging to the human body. Tin houses are what we call mobile homes in life, like being built on a construction site for construction workers.

    1. What is the solution to cool down if the tin room is too hot?

    1. Brush the top of the iron sheet white, so that at the end of the day, the heat will be slightly reduced, but the effect is not obvious.

    2. Sprinkle water in the room or put some water in the room, which is the same principle as air conditioning, try to make the air humid.

    Lower it a little. 3. Choose a thermal insulation board.

    There are several options, the materials of the insulation layer are extruded polystyrene insulation board is a good building insulation material, glass wool.

    It is also a commonly used insulation material, but the thermal conductivity of glass wool.

    It is not as low as the extruded insulation board, and the effect is not as good as it.

    What do you need to pay attention to in the decoration of the tin room.

    1. Pre-embedded anchor bolts.

    The distance from the edge of the concrete short column is too close. When embedding bolts, the side bolts of the steel column should not be too far to the side, and should leave enough distance from the column edge. At the same time, the concrete short column should ensure that the design strength is reached, and the hoisting work of the rigid frame can be organized.

    2. It is often easy to forget the retention of the shear groove and the setting of the shear resist; The gap between the bottom plate of the column foot and the concrete column is too small, which makes it difficult to fill or fill the grouting material. Generally, the secondary filling void is 50mm.

    3. The two rigid frames supported between the columns of the gable should be installed first, and then other rigid frames should be installed. After the installation of the first two rigid frames, the horizontal tie rods and purlins should be placed between the two rigid frames.

    And the inter-column support, the horizontal support of the roof, the corner brace are all installed, and the verticality of the components should be adjusted by using the inter-column support and the horizontal support of the roof after the installation is completed.

    and levelness, the support can be locked only after the adjustment is correct, and then other steel frames are installed.

    4. The position of some engineering anchor bolts is not accurate, in order to facilitate the rigidity of the frame hoisting in place, the bottom plate is perforated twice on the spot, and the arbitrary cutting is arbitrary, resulting in the opening of the column foot bottom plate is too large, so that the column foot is not fixed firmly, and the small side (end) distance of the anchor bolt can not meet the requirements of the specification.

  2. Anonymous users2024-02-11

    I don't think the indoor environment is good, and it's only suitable for temporary use. The thin body of the house leads to cold in winter and hot in summer, and poor thermal insulation performance.

  3. Anonymous users2024-02-10

    1.not ventilated; Very occlusive and prone to breathing difficulties.

    2.thunder and rain; There will be a danger of lightning strikes.

    3.The noise is loud; Affects normal dormancy.

    4.Summer is too hot, after a day of sun exposure, and the iron sheet absorbs heat, people are prone to sweating, and a lot of sweating will cause people to collapse.

    5.Winters are too cold; Moreover, iron is magnetic, easy to absorb electromagnetic waves, and it is also very damaging to the human body.

Related questions
4 answers2024-07-02

The teacher asked a question: In addition to dilapidated houses, what kind of houses are not inhabitable?

22 answers2024-07-02

I think, as long as you pay attention to supernatural events. >>>More

27 answers2024-07-02

The temperature is too low to be inhabitable.

10 answers2024-07-02

Surpass. China's "Indoor Air Quality Standards" stipulates that the limit of formaldehyde in the indoor air of Class II civil construction projects is, and the limit of formaldehyde in the indoor air of Class I civil construction projects is. One of the types of civil construction works includes: >>>More

30 answers2024-07-02

The high-rise floor is more suitable for people to live in, and the auspicious floor is; >>>More