According to the number of horses, the maximum copper tube of 33t is 22.
The piping, wiring, and routing requirements of multi-online air conditioning products are very strict, and if the operation is not standardized, it is easy to cause the air conditioner to fail in one way or another. It is recommended to operate in strict accordance with the installation and operation instructions provided by the multi-online manufacturer or the piping requirements in the installation manual. The installation manual or installation manual has detailed requirements for the piping of each type of multi-online product.
There are three outstanding characteristics of refrigeration copper tubes: one is overcapacity, the other is serious product homogenization, and the third is that the supply of low-end products exceeds demand, and high-end products are in short supply.
-
It's not clear what to ask. Branchers can be cut. 33t max. The trachea can be taken with 19 points out, you can use 16 points out 12 10 liquid pipes can take 12 points out of 10 points out of 6 to take what you need. Assigned by internal machine.
-
This depends on the number of horses on your external machine, 33t and the maximum copper pipe is 22.
-
1. Under normal circumstances, the copper pipe is connected with the indoor unit after the bell mouth is expanded, and the copper pipe is connected with the outdoor unit with a large number of horses, which is generally brazed.
It is connected by welding, and connected with the outdoor unit with a small number of horses, and is generally connected with a copper nano after using a bell mouth.
2. The purpose of the divergent tube is to distribute refrigerant.
Flow, air conditioning products of various manufacturers, according to the capacity of the outdoor unit and the number of indoor units, different types of divergent pipes should be selected, and the two pipes on the divergence pipe are of different thicknesses, and different diameters should be selected according to technical requirements.
3. The hanger of the refrigerant copper pipe uses an ordinary lead screw.
If it is more beautiful, it is best to use a metal bridge, and the part from the outdoor unit to the pipe well is best to use a bridge to avoid stepping on the copper pipe to cause deformation, which will affect the flow of refrigerant. The hoisting of the main pipeline has little to do with the pipe diameter, and the spacing requirements of the boom are: horizontal pipe routing, about one meter, and about 2 meters for the vertical pipeline part.
4. The larger the outer diameter of the copper pipe, it is best to use a 90-degree formed copper pipe elbow when the pipeline is bent, if it is below the diameter, you can use the pipe bender to bend the pipe directly, and if the elbow is used, it does not need to be calculated separately, as long as the number and total price of the elbow are calculated, if it is an elbow, it needs to be calculated.
5. Condensate pipe, if it is PVC DN40 or above, it is generally used as the main drainage pipe, the spacing of the boom is about 1m, the general branch pipe is DN25 or DN32, and the boom requires one, to ensure that the slope of the water pipe is more than 1 100 or 1 50.
-
Liquid pipe, trachea, but normally, the size of the main pipe is calculated according to the specific size of the copper pipe of the indoor unit.
Daikin is Gree's OEM, which is a bit fantastical. Gree bought inverter technology from Daikin. Daikin can be said to be the leader of air conditioning. >>>More
Split machine: For example, split wall-mounted machine FTXP25HV2CW, N, P F means indoor unit T means wall-mounted machine X represents new refrigerant P means P series 25 means that the cooling capacity is 2500W, that is, 1HP The W behind means Phantom Gold White White N means Phantom Gold P means Phantom Gold Purple RXP25HV2C This is the host of FTXP25HV2CW, N, P Generally, the host that starts with R is the main engine** air conditioner, different series of internal units are differentiated FJ The beginning is the VRV internal machine, the beginning of the FX is the VRVIII internal machine, the FQ starts with the VRV-N internal machine, the FZ starts with the CMS series of the internal machine, in fact, it is regular. Just remember the first few letters! >>>More
1. The power supply mode is different. The power supply of the outdoor unit is from the main control panel of the indoor unit, and the relay is specially operated before it begins to supply power to the outdoor unit, and whether the indoor unit is powered is completely determined by the power supply installed in the indoor unit. >>>More
The main difference between the two is that they are all the same, and then relatively speaking, the model is exactly the same, and the use effect is not much different.
It is normal for the copper pipe of an air conditioner to drip because the temperature outside is high and the temperature of the refrigerant flowing inside the copper pipe is low. If the weather is hot or cold, the surface of the copper pipe will condense, so it can be wrapped with insulation material. If the copper pipe is exposed, the air conditioner will drip when it is running, and the copper pipe needs to be wrapped with insulation material. >>>More