How can I make the data of the flow meter larger?

Updated on technology 2024-08-06
18 answers
  1. Anonymous users2024-02-15

    According to the working principle, it can be divided into the following types: l rotameter l gas mass flowmeter l turbine flowmeter l ultrasonic flowmeter l electromagnetic flowmeter l vortex flowmeter l volumetric flowmeter l differential pressure flowmeter and the rotameter in your picture is a rotameter: called a float flowmeter, and its flow detection element is composed of a vertical conical tube that expands from the bottom to the top and a float that moves up and down along the shaft of the cone.

    When the measured fluid passes through the annular gap formed by the cone tube and the float from the bottom up, the force of the float rising is formed. When the lifting force is equal to the weight of the float immersed in the fluid, the float stabilizes at a certain height. This height value is the flow value of the fluid.

    For more professional answers, please contact Shanghai Kekun Industrial Science and Technology Development, product service: Shanghai Kekun Industrial Science and Technology Development, is a professional from...

  2. Anonymous users2024-02-14

    Processed on a case-by-case basis. Electromagnetic flowmeter.

    The measuring principle is based on Faraday's law of electromagnetic induction.

    After using the electromagnetic flowmeter for a period of time, it will sometimes be found that the electromagnetic flowmeter has no medium flowing in the pipeline, and the electromagnetic flowmeter will also have instantaneous flow values in the case, so how to deal with this situation is what the user must know, and there are many reasons for this problem, first of all, it is necessary to exclude whether the electrode is polluted, whether the electromagnetic flowmeter sensor is damaged and whether the flow zero point of the electromagnetic flowmeter is normal, etc., and the specific elimination method is:

    Check that the fluid medium in the process piping is filled with pipes.

    Check whether the flow rate of the fluid through the pipeline is normal in the process.

    If the electrode is contaminated, clean the electrode and check whether the electrode is damaged.

    Check the electromagnetic flowmeter sensor.

    To adjust the flow zero point of the flow meter, the specific steps are as follows:

    Fill the pipe of the electromagnetic flowmeter with medium (must be a metal pipe), close the valves at both ends of the electromagnetic flowmeter, and make the medium in the pipeline in a full and stationary state.

    Enter the electromagnetic flowmeter converter menu, refer to the electromagnetic flowmeter instruction manual to check whether the content of each menu meets the initial setting (it cannot be ruled out that the electromagnetic flowmeter will be adjusted by other personnel in use), and correct the zero point of the flow rate to .

    After the zero point is corrected, observe whether the instantaneous flow rate is zero and no longer changes.

    If there is no problem with the above inspections, the electromagnetic flowmeter will generally be returned to the factory for inspection and maintenance.

  3. Anonymous users2024-02-13

    Flowmeter, adjust the bottom probe, into the signal, will make the data larger.

  4. Anonymous users2024-02-12

    There is no other way to adjust the parameters.

  5. Anonymous users2024-02-11

    The method of modifying the flow rate under real working conditions, when the instantaneous flow rate of the current electromagnetic flowmeter is Q1 and the K coefficient is K1, when the actual desired flow rate is Q2, it is necessary to modify the value of the current K coefficient K2 and adjust the current one.

    Flow rate, can be achieved by modifying the current k coefficient, assuming that the new k coefficient value is k2, k2 is equal to the actual desired flow rate q2 divided by the instantaneous flow rate q1, multiplied by the current k coefficient k1, i.e., k2=

    q2/q1)*k1

    For example, the electromagnetic flowmeter shows that the current instantaneous flow rate is Q1=, and the instrument coefficient K1= is set inside the electromagnetic flowmeter, and the actual flow rate Q2= can be verified according to field experience or other methods, then the actual desired flow rate can be obtained by modifying K1

    That is: k2=(q2 q1)*k1=(, the obtained k2 will be re-set to the column of the meter coefficient of the electromagnetic flowmeter, replacing the original k1, and the new instantaneous flow q2 will be obtained.

  6. Anonymous users2024-02-10

    You didn't specify what type of flow meter it is?

    This cannot be adjusted solely on the basis of a single point of data, but must be adjusted from the entire range.

  7. Anonymous users2024-02-09

    This is to be adjusted in the range, for example, the corresponding flow range of 4-20mA is 0-100L min, which is to be set.

  8. Anonymous users2024-02-08

    The flowmeter is connected to the computer through the RS485 line, and then connected to the computer through the RS485 to RS232 converter, and then the test configuration software is set. The converter can be done for 500 yuan. But this can only receive 485 signals, can not collect 4 20mA current signals, 4 20mA requires a special capture card to convert to 485.

    485 is the current instantaneous and cumulative amount of the reading data. 4 20mA is just a signal that indicates the instantaneous flow rate, and it needs to be accumulated by the computer software itself.

  9. Anonymous users2024-02-07

    Install 360 Security Guard, with traffic monitoring.

  10. Anonymous users2024-02-06

    Select the PID control regulator.

    What you actually have to solve is to control the temperature of the water, right? You can monitor the effluent temperature to control the amount of steam, which is usually the case. Fluctuating steam flow is a problem with your system.

  11. Anonymous users2024-02-05

    I don't know what you mean. What do you want to do with this?

  12. Anonymous users2024-02-04

    Yes, there are many ways, but that kind of data is inaccurate.

  13. Anonymous users2024-02-03

    It depends on what kind of parameters you choose the mass flow meter, if it is intelligent, it can be achieved through computer software, and the table itself also has a setting button, Sieea brand, imported from the United States, the quality is good, but it is not cheap.

  14. Anonymous users2024-02-02

    With the help of a communicator (see what protocols are supported, there are usually HART, Honeywell, etc.) or a computer. Or change it directly on the flow meter.

  15. Anonymous users2024-02-01

    Take a look at the gauge. Whether it is caused by electromagnetic interference.

  16. Anonymous users2024-01-31

    The pipeline fluid is not full

  17. Anonymous users2024-01-30

    Welcome to call Beijing Hairuituo Instrument Technology Center.

    will give you a comprehensive answer.

    Beijing Hairui Gaodantuo Company is located in the center of China's politics, economy, science and technology, and culture.

    It is a high-tech enterprise specializing in the research and development, production and sales of valves and automation instruments.

    The products developed by the company are: high-precision electromagnetic flowmeter, high-precision color paperless recorder, portable ultrasonic flowmeter, turbine flowmeter, steam vortex flowmeter, metal rotameter, target flowmeter, orifice flowmeter, fine and small pressure transmitter, differential pressure transmitter, temperature transmitter, magnetostrictive liquid answering transmitter, anti-corrosion ultrasonic level meter, pilot radar level meter, radio frequency Qi osmosis admittance level meter, pH analyzer, COD analyzer, ammonia nitrogen analyzer, liquid level switch, etc.

    New R&D products: ultrasonic flaw detector, ultrasonic thickness gauge, coating thickness gauge, hardness tester, laser rangefinder. It is mainly used in iron and steel smelting, chemical industry, environmental protection, sewage treatment, electric power, medicine, minerals and other industries, and the products are exported to Southeast Asia, Pakistan, Iran, North America, etc.

    OEM production can be carried out according to the actual requirements of the customer's site.

  18. Anonymous users2024-01-29

    And Shunda electromagnetic flowmeter technical performance indicators alarming chain:

    Flow velocity measurement range: (

    Measuring pipe diameter: DN(32-6000)mmInstrument accuracy: grade.

    Working Pressure:

    Medium temperature: 0-80 liquid Lasun.

    Power consumption: 15VA

    Grade: IP68

    Connection: flange connection.

    Electrode materials: molybdenum-containing stainless steel OCR18Ni12Mo2Ti, Hastelloy B, Hastelloy C, titanium Ti, tantalum, etc.

    and Shunda electromagnetic flowmeter.

Related questions
5 answers2024-08-06

The English name of the flowmeter is flowmeter, which is defined by the National Committee for the Examination and Approval of Scientific and Technical Terminology as: an instrument that indicates the measured flow rate and/or the total amount of fluid in a selected time interval. To put it simply, it is an instrument used to measure the fluid flow in the pipeline or open channel, and the commonly used unit m3 h in engineering can be divided into instantaneous flow rate (flow rate) and cumulative flow (total flow), the instantaneous flow rate is the amount of effective cross-section of the closed pipeline or open channel per unit time, and the flowing substance can be gas, liquid and solid; The cumulative flow rate is the cumulative amount of fluid flowing through the effective section of a closed pipe or open channel at a certain interval (one day, one week, one month, one year). >>>More

9 answers2024-08-06

A gas flow meter is an instrument used to measure the flow rate of gases. They can be used to measure a variety of gases, including air, oxygen, nitrogen, hydrogen, carbon dioxide, and more. Gas flow meters typically use a pressure sensor or flow sensor to measure the gas flow rate, and the measurement results can be displayed through a digital display or output signal.

7 answers2024-08-06

1. Good repeatability, high accuracy, calibrated wedge flowmeter, accuracy up to level. >>>More

14 answers2024-08-06

The hydrogen flow meter is suitable for other gas flow measurement, with simple installation, easy maintenance, explosion-proof function, safe and reliable use. >>>More

11 answers2024-08-06

Turbine flowmeters work using the principle of fluid momentum and torque. >>>More