High voltage reactive power compensation, what are the effects of high voltage on reactive power com

Updated on technology 2024-03-08
7 answers
  1. Anonymous users2024-02-06

    Regardless of the voltage level, reactive power compensation is divided into capacitive compensation and inductive compensation. However, the compensation is usually capacitive compensation, because the capacitive compensation is very small, usually only in the process of road transmission, the mutual inductance between the lines is capacitive, and most of the loads are capacitive inductive loads that require capacitance compensation. The difference between them is that the circuit is turned on at the moment, whether the reactor bears the impact or the capacitor bears the impact, because our reactor is produced by ourselves, and the impact resistance is strong, so I generally connect the reactance first.

    The reactor and the capacitor form an LC tuning loop for a specific harmonic, so that the impedance of the filter branch to a certain harmonic is very low, and this filter branch plays the role of filtering. The selection of reactor is related to the capacitance of the capacitor and the number of filtering. The choice of contactor depends on the voltage level, current size, breaking capacity, and whether it is frequently switched, like 10kV 6kv usually uses vacuum contactor, but pay attention to:

    In 10kV and 6kV systems, the vacuum contactor is not fully suitable for frequent switching. The capacitor selection is mainly the voltage level, the capacity of compensation, the elevation of the capacitor voltage by the reactor, and so on.

    A reactance is only related to the capacitance of the capacitance, and has nothing to do with the number of capacitors.

    There are many things to pay attention to about the design of the filter, such as the number of harmonics, the size of harmonics, the short-circuit capacity, etc., not a few words can be finished, if necessary, you can q me or send me an email.

  2. Anonymous users2024-02-05

    1. Active power determines frequency, reactive power determines voltage, when the voltage is high, the capacitor can not be put in, and then the capacitor will make the voltage higher, and the high voltage will also harm the safety of the capacitor itself;

    2. The voltage is very high during the day, and the voltage is higher at night, so the capacitor can not be put into it, and the high voltage is not only harmful to the capacitor, but also harmful to other electrical equipment; Hungry beat.

    3. If the power factor is low, especially when paying the electricity bill, you should pay the "power factor" fine, then the power factor should be increased, the easiest way is to change the section switch of the transformer, reduce the voltage of the transformer, and then put in the capacitor;

    4. If your load is relatively small, you can replace the transformer with a smaller capacity, such as 50kva, or 30kva, which not only reduces the power loss of the transformer itself, but also saves electric energy;

    5. If the power consumption capacity is small, the reactive power compensation that needs to be adjusted should also be fine, and the capacitor with small capacity is required, and the compensation amount of a single capacitor should not be greater than 1 3 of the capacity of a single electrical equipment. If the capacitance of the capacitors in the compensator is not consistent, the compensator controller should be adjusted and set.

    Reactive power compensation, referred to as reactive power compensation, plays a role in improving the power factor of the power supply system of the power grid, reducing the loss of power supply transformers and transmission lines, improving power supply efficiency and improving the power supply environment. Therefore, the reactive power compensation device is in an indispensable and very important position in the power supply system. Reasonable selection of compensation devices can minimize the loss of the power grid and improve the quality of the power grid.

    On the contrary, if the selection or use is improper, it may cause many factors such as power supply system, voltage fluctuations, harmonic increases, etc.

  3. Anonymous users2024-02-04

    Hello, the high-voltage reactive power compensation device can be provided by the power supply enterprise or the user himself. According to the provisions of the "Measures for Adjusting the Electricity Charge of the Power Factor of Accompanying Return", the power factor standard is the assessment standard, the standard, and the preferential standard. If the load power factor is lower, the electricity fee will be increased, but if it is higher, you may get a discount on the electricity fee.

    For the adjustment of reactive power, the method of reactive power compensation can be adopted to improve the power factor. Reactive power compensation equipment generally includes high-voltage reactive power and defect disorderly compensation device, low-voltage reactive power compensation device, 10 thousand volt reactive power compensation device, distribution transformer reactive power compensation and electrical equipment reactive power compensation. In short, the high-voltage reactive power compensation device can be provided by the power supply enterprise or the user himself, and the user's limb needs to be determined through consultation with the power supply enterprise.

    High-voltage reactive power compensation devices are usually provided by power equipment manufacturers or power engineering companies. These companies specialize in the development and production of a wide range of power equipment, including high-voltage reactive power compensation devices. They have a wealth of experience and expertise to provide high-quality products and solutions.

    High-voltage reactive power compensation device is a kind of equipment used in the power system to compensate the reactive power in the power system and improve the power factor of the system. It can compensate for reactive power by adjusting the phase difference between current and voltage. High-voltage reactive power compensation devices are usually composed of capacitors, reactors, controllers and protection devices, which can effectively improve the stability and reliability of the power system.

    There are many benefits to using a high-voltage reactive power compensation device. First of all, it can improve the power factor of the power system, reduce the loss of reactive power, and improve the efficiency of electric energy utilization. Secondly, it can improve the voltage quality of the power system, stabilize the power supply, and reduce the voltage fluctuations and harmonics in the power system.

    In addition, the high-voltage reactive power compensation device can also reduce the current loss of the power system and improve the power transmission capacity. In addition to power equipment manufacturers and power engineering companies, some professional power system integrators and engineering consulting companies can also provide high-voltage reactive power compensation devices. They are able to provide customized solutions according to the customer's needs and actual conditions, and install, commission and maintain high-voltage reactive power compensation devices.

    In summary, high-voltage reactive power compensation devices are usually provided by power equipment manufacturers, power engineering companies, power system integrators, and engineering consulting firms. They are able to provide high-quality products and solutions to meet the needs of customers, and provide corresponding installation, commissioning and maintenance services.

  4. Anonymous users2024-02-03

    Hello, about the provision of high-voltage reactive power compensation device, the following schemes can be considered according to different situations:1If it is a reactive power demand caused by industrial and commercial users, the reactive power compensation device should be provided and installed by the power users themselves.

    This is in accordance with the provisions of the Law on the Management and Rent Management of Reactive Power Compensation for Electricity Users. 2.If the reactive power loss of the power grid itself needs to be compensated, the reactive power compensation device can be configured by the power generation enterprise or the power grid enterprise itself.

    3.For important public facilities such as airports, hospitals, etc., if reactive power compensation has an important impact on power quality, reactive power compensation devices can also be provided by power grid enterprises or relevant departments. 4.

    For the reactive power compensation of residential users, the power distribution enterprise can set up a compensation device, but the cost may be passed on to the user's electricity price. 5.If the capacity of the reactive power compensation device is large, the installer can apply for the joint construction of the compensation device with the power generation enterprise or the power grid enterprise, and the two parties can sign a power purchase and sale agreement.

    6.If conditions permit, virtual reactive power compensation can also be considered to save hardware investment. To sum up, the provision of reactive power compensation rental device needs to be determined according to the actual situation, and the user-provided mode is mostly adopted, and a more economical compensation scheme can also be realized through multi-party cooperation.

  5. Anonymous users2024-02-02

    Summary. The reactive power compensation is particularly high, which will make the voltage of the power system increase and affect the life of electrical equipment, easy to produce overvoltage and resonance to affect the power equipment, and reduce the power quality due to the increase of power in the line.

    The reactive power compensation is particularly high, which will increase the voltage of the power system and affect the life of electrical equipment, and it is easy to produce such as selling overvoltage slag and resonance to affect power equipment, and the power quality will decrease due to the increase of power in the line.

    What is the reason for the reactive electricity bill of more than 3000.

    The reason for the reactive power socks is that the reactive power compensation of the line or equipment is insufficient, resulting in the power factor of the yard is lower than the power specified by the power supply department, and the power factor is lower than the reactive power charge charged below.

  6. Anonymous users2024-02-01

    Hey. In the 31 years that our company has been engaged in the research and development, production and sales of reactive power compensation equipment, there are often novices who ask us similar questions. This way:

    The monthly average power factor is generally used by the power supply company to assess the user's data, and he uses the active electricity consumption of the month and the reactive power consumption of the month to calculate, and the calculation formula is:

    Monthly average power factor = monthly active power [(square of monthly active power + square of monthly reactive power)open squared].

    Say a few more words: because the technology of the conventional compensation cabinet is very mature, and the components used in the cabinet are also very mature, so a large number of small factories and even small roadside electrical appliances stores dare to make compensation cabinets, which is a very fatal thing, because the technology of the industry is mature, does not mean that the producer's process and technology are mature, and does not mean that the producer does not use fake and inferior components and materials, especially a large number of low-cost cottage compensation controllers flood the market, ** looks very attractive, but a fine is enough for you to bear. Therefore, it is necessary to use a qualified manufacturer's cabinet.

    Improving the power factor and doing reactive power compensation is an energy-saving technology advocated by the state, but it is highly professional and needs professionals to do it. More about reactive power compensation, power factor, etc. and other issues and information, you can four cores, you can also find and discuss here, here is a group of retired electrician old men who have studied in college, they can't do much, but they are all happy to help young people.

  7. Anonymous users2024-01-31

    1. The use of reactive power compensation technology to improve the power factor of low-voltage power grid and electrical equipment is an important measure for power-saving work;

    2. Reactive power compensation, which is to provide the necessary reactive power with the help of reactive power compensation equipment, so as to improve the power factor of the system, reduce energy consumption, improve the voltage quality of the power grid, and stabilize the operation of the equipment;

    3. Reduce power loss, general factory power wiring according to different lines and load conditions, its power loss; About 20%-30%, after using capacitors to increase the power factor, the total radio wave is reduced, which can reduce the power supply flow and power loss at the power consumption end;

    4. Improve the quality of power supply, increase the power factor, reduce the total current and voltage drop of the load, and install capacitors on the secondary side of the transformer to improve the power factor and increase the voltage on the secondary side.

    5. Extend the life of the equipment, reduce the total current of the line after improving the power factor, and reduce the capacity load of transformers, switches and other machinery and equipment that are close to the middle and have been saturated, so that the temperature rise can be reduced and the life can be increased (the life can be extended by 1 time for every 10 degrees Celsius decrease in temperature).

    6. Finally, it meets the monitoring requirements of the power system for reactive power compensation, and eliminates the fines caused by the low power factor.

    7. Reactive power compensation can improve power quality, reduce power loss, tap the potential of power generation and power supply equipment, and reduce user electricity expenses by reactive power compensation, which is an energy-saving measure with less investment and quick results.

    8. The impact of reactive power compensation technology on the low-voltage distribution network of the power unit and the economic and social benefits brought by improving the power factor, determine the compensation capacity of reactive power, ensure that the compensation technology is economical, reasonable, safe and reliable, and achieve the purpose of saving electric energy.

Related questions
8 answers2024-03-08

Low-voltage reactive power compensation refers to the installation of compensation devices in the low-voltage 400 (380) volt network of distribution transformers, including random compensation, follow-up compensation and tracking compensation. >>>More

5 answers2024-03-08

Line loss and transformer loss need to be considered! You estimate that it is enough to compensate 2000kvar on the 35kv side.

18 answers2024-03-08

This shows that it is overcompensated and prone to such problems when operating at low loads. The main reason is that the capacity of the first few sections of the capacitor is set too large (generally no matter how many sections are the same capacity), when running at low load, cut off a capacitor to undercompensate, and after investment, it will be overcompensated. The reactive power assessment of the power supply company is: >>>More

6 answers2024-03-08

Hey. Users themselves can't turn! If you want to transfer, you can only transfer it by the manufacturer. >>>More

6 answers2024-03-08

If you are using an automatic reactive power compensator, you can see if the capacitance compensation display is fully invested when the power factor is used, if not, the compensator is broken, or the compensator parameter setting is wrong. >>>More