How big capacitor should the 220V60W geared motor be equipped with

Updated on technology 2024-03-26
12 answers
  1. Anonymous users2024-02-07

    It's one of those little all-plastic fans.

    That small fan is similar to a stepper motor.

    Speed regulation can only be solved by adjusting the frequency of the power supply. In general, capacitors will reduce the current flowing through the motor, resulting in a decrease in the rotational torque, which may lead to impermanent operation.

    The capacitance is not as large as possible, through the same frequency of alternating current.

    The larger the capacitance, the capacitive reactance.

    The smaller it is, the greater the current flowing. If the resonant frequency of the LC series is close to or equal to the frequency of the power supply, it may cause the fan to burn out or the capacitor to be damaged, so it is best to connect a fuse in series during the test. As long as the voltage across the capacitor does not exceed its maximum operating voltage, it is safe.

    Only non-polarized capacitors, such as film capacitors, can be used, and they cannot be electrolytic capacitors.

    The capacitor does not need to be added to the live wire, but the switch must be connected to the live wire! You can use a voltage tester to judge the line of fire, which is available in hardware stores. The hand touches the metal of the cap, and the nib touches the charged metal, the neon lamp inside.

    Bright is the line of fire.

    For a properly installed socket, when facing the jack, the left hole is zero and the right hole is fire.

    If you don't have a foundation, it's better not to try, electricity is quite fun, but it is also quite dangerous. Don't let the small be the big one. It is recommended that you have a small desktop fan, which is not expensive.

    There are many kinds of resistors, if you want to know more detailed technical parameters, go to the hard city to understand, it is better than to solve professional problems here, which is very realistic.

  2. Anonymous users2024-02-06

    Generally 4 microfarthic 450 volt capacitor.

  3. Anonymous users2024-02-05

    50W single-phase motor distribution capacitor is fine.

    Professional motor maintenance and repair center motor maintenance process: cleaning stator and rotor - replacing carbon brushes or other parts - vacuum F-class pressure impregnation - drying - calibration balance.

    1. The use environment should always be kept dry, the surface of the motor should be kept clean, and the air inlet should not be hindered by dust and fibers.

    2. When the thermal protection of the motor is continuously activated, it should be found out whether the fault comes from the motor or the overload or the setting value of the protection device is too low, and the fault can be put into operation only after the fault is eliminated.

    3. Good lubrication of the motor during operation should be ensured. The general motor runs for about 5000 hours, that is, the grease should be supplemented or replaced, and when the bearing is found to be overheated or the lubrication deteriorates, the hydraulic pressure should change the grease in time. When replacing the grease, the old lubricating oil should be removed, and the oil groove of the bearing and bearing cover should be cleaned with gasoline, and then the ZL-3 lithium grease should be filled with 1 2 (2 poles) and 2 3 (opposite poles) of the cavity between the inner and outer rings of the bearing.

    4. When the life of the bearing ends, the vibration and noise of the motor operation will increase significantly, and the radial clearance of the bearing should be replaced when the radial clearance of the bearing reaches the following values.

    5. When disassembling the motor, take out the rotor from the shaft extension end or non-extension end. If it is not necessary to remove the fan, it is more convenient to remove the rotor from the non-shaft extension, and when removing the rotor from the stator, it should be prevented from damaging the stator windings or insulation.

    6. When replacing the winding, you must write down the form, size and number of turns of the original winding, wire gauge, etc., when these data are lost, you should ask the manufacturer to change the original design winding at will, often make one or several performance of the motor deteriorate, or even unusable.

  4. Anonymous users2024-02-04

    Single-phase operating capacitance formula: C 1950 i u cos (i: motor rated current, u: power supply voltage, cos: power factor is between) find the rated current of 140w motor: i p u cos

    The power factor is increased by capacitance compensation in normal operation, and the COS is I 50 220

    Find the operating capacitance: C 1950

    The working capacitance is calculated as 100W=2UF, and the starting capacitance is 5-7 times that of the working capacitance.

    Generally, 550W-2200W motors are 450V200 F, which can be started normally. The operating capacitor has also played an auxiliary role in starting, generally according to 2 3 micro-methods per 100W distribution capacity, and it is advisable to use micro-methods.

    So 50w single-phase motor distribution capacitor is fine.

  5. Anonymous users2024-02-03

    The dehydrator is equipped with about 4uf, and the fan motor is equipped with about 2uf. Why is the capacitor of the same large motor different? That's because some motors are started at full load, and the copper wire of the secondary winding of the motor is used thicker in the design, a little or even more than the wire diameter of the main winding, so that the capacitor is used large, in order to improve the starting performance.

    On the contrary, some of the starting load is lighter, and the copper wire of the secondary winding is thinner, so that the capacitor is used a little smaller, and it can also be started. In addition, the power marked on some motors does not match the actual one, and the specific capacity of the capacitor is not clear.

  6. Anonymous users2024-02-02

    If you want to connect the three-phase 380 volts 1,000 watts of electroosmotic bi motor cluster source to the 220 volts single-phase power supply, and keep the power basically unchanged, first of all, the original star connection should be changed to a triangle connection (the connection method is shown in the figure), after the reconnection, according to the circuit diagram, connect the capacitor, the 100 watt motor roughly needs to be equipped with a non-polarized capacitor with a voltage of 450 volts and a capacity of about 30 microfar, if the load requires a large torque, it is necessary to configure the starting capacitor of a series switch. The starting capacitor can be selected with a withstand voltage of 220 volts or more, and a capacity of 200 microfarnates.

    For single-capacitor motors, the starting capacitor can be selected to withstand voltage of more than 220 volts, and the capacity of 200 microfarads or slightly more. Dual-capacitor motor, the operating capacitor is selected as 25 micro-method, the crack ear pressure is 450V or above, and the starting capacitor is selected to withstand the voltage 220V and the capacity is 200UP or omitted.

  7. Anonymous users2024-02-01

    A 100 microvolt capacitor is required. According to the relevant public information, 10 microvolt capacitors are equipped for every 100 watts, 1000 watts are equipped with 100 microvolt capacitors, and 220V kilowatt motors are equipped with 100 microvolt capacitors. Capacitance, also known as "capacitance," refers to the difference in a given potential.

    The reserve of the lower free charge is denoted as the front good c and the SI unit is farad (f).

  8. Anonymous users2024-01-31

    The capacitance of a single-phase motor (taking a 1 kilowatt motor as an example) is selected as follows:

    1. Starting capacitance: c=8js( f), J - current density of motor starting winding.

    Generally choose 5 7A mm2; S-Qi Cong is used as a cross-sectional area of the spine winding wire (mm2).

    2. Single-phase operating capacitance formula: C 1950 i u COS, i - motor rated current.

    U - Supply Voltage, COS - Power Factor.

    1kw motor distribution capacitance c=1950*.

    3. For the starting capacitor, it only needs to generate phase-shifting rotational electromotive force.

    so it can be selected in a wide range. All motors use 450V200 F non-polar capacitors.

    4. According to the infiltration experience, the operating capacitor can be selected as 450V30 F

  9. Anonymous users2024-01-30

    Pro, I'm glad to answer for you: How big is the capacitance of a 120W motor Answer: Pro, single-phase running capacitance formula:

    C 1950 i u cos (i: motor rated current, u: supply voltage, cos:

    The power factor is interval) Split-phase capacitor capacity formula: c=350000*i 2p*f*u*cos withstand voltage formula: u (capacitance) greater than or equal to c is the capacitance; i is the current; f is the frequency; u is the voltage; The power factor is 2p=2 high, and the power factor is 2p=4;cos is the power factor.

    The formula for the operating capacitance capacity of a dual-value capacitor is: c=120000*i 2p*f*u*cos 2p=24 Withstand Voltage Formula:

    U (capacitance) is greater than or equal to (2 U Starting Capacitance Capacity Formula: C = (Running) Withstand Voltage Formula: U (Capacitance) is greater than or equal to The capacitance is too large, resulting in excessive motor current and large starting torque.

  10. Anonymous users2024-01-29

    Summary. How much does the starting capacitor and running capacitor of the 220V motor power 750W need to be calculated: the operating capacitance is calculated as every 100W2 to 4UF, and the starting capacitor is calculated as 2 to 4 times the running capacitance of the amper.

    How big does the power of the 220V motor 750W start the stove and the running capacitor need: Xiaosui calculates the operating capacitance per 100W2 to 4UF, and the starting capacitor is 2 to 4 times the running capacitance.

    220V750W single-phase motor with 6 to 8 microfarad capacitors, withstand voltage 450V.

  11. Anonymous users2024-01-28

    Hello dear, how big capacitor should a 250W motor be equipped withHow big is a starting capacitor for a 250W motor? Equipped with 6-8uF capacitors. Generally speaking, a 250W motor should be equipped with a withstand voltage of 400 to 40 or 50 volts and a capacity of 8 to 10 microfarnes.

    The calculation formula of single-phase motor running capacitance is Yu Pa Zhao Zhao C=1950i UCOS (microfar) formula, i is the motor current, U is the power supply voltage, COS is the power factor, 1950 hope mine can help you; Once again, I wish you good health and a good mood! 

  12. Anonymous users2024-01-27

    How big capacitor does a 160W220V single-phase motor have? 160 watt two-phase motor with 10 microfaring capacitors. Single-phase motor 160 watts This motor is smaller than Oak Reputation.

    There are many occasions suitable for work, because this kind of motor is convenient to use electricity, and it is convenient to work, and the power of the equipment that can be driven is small, but it is also very good, and when choosing a capacitor, it is necessary to pay attention to the capacitor withstand voltage value must be greater than 400 volts. 160 watt two-phase motor with 10 microfaring capacitors. There is a formula for calculating the starting capacitance:

    c = 1950i ucos , 1950 is the constant, cos is the power factor, and u is the voltage. The current flowing in a single-phase motor is single-phase, which cannot produce a rotating magnetic field, and the phase is adjusted with capacitors, and the current in the windings produces a phase difference of 90 degrees. There is a normal winding called the main winding in the single-phase motor, and there is also a starting winding on the stator, which is to make the current of the two windings produce a phase difference of 90 degrees.

    When the motor speed reaches a certain speed, the contact piece of the starting winding is detached under the action of the force of circular motion. The main winding is working fine. The process is short.

    If my answer is helpful to you, please give a thumbs up (in the lower left corner), I look forward to your like, your efforts are very important to me, and your support is also the motivation for my progress. Finally, I wish you good health and a good mood!

Related questions
22 answers2024-03-26

Electricity is like water, flowing from there to the bottom. Of course, the same goes for electricity, and there is also an electric current in the 0 line, which flows back to the transformer. When you test with an electronic voltage tester, there is a potential difference but it is very small. >>>More

12 answers2024-03-26

Thanks to the inverter.

The internal MOSFETs are turned off when not working, and only the internal parasitic diodes. >>>More

6 answers2024-03-26

220 volts is a group of live wires and a group of neutral wires, 380 volts is two groups of live wires and a group of neutral wires, 380 volts are suitable for large load power, 220 volts are suitable for small load power.

17 answers2024-03-26

As for the so-called "spike voltage" I think it varies from person to person, from environment to environment, no one can say that below 36V is absolutely safe, how much V or more is absolute spike (if you say 100,000 volts or 1 million volts is absolute spike, then I can only agree). If I say 110V is safe, I just mean that it is relatively safe, or relatively safe. Neither 110 nor 220 is absolutely safe for people. >>>More

9 answers2024-03-26

The resistance of the household 220V socket can be measured, and the resistance is normal to 0 because the conductive part of the socket is generally made of copper, and the length is short, so the resistance is very small, but there are many shoddy modern products, and there may be sockets with great resistance, so that it is easy to heat up when used, and even lead to fire, so it is necessary to measure. >>>More