What is the matter with the leakage and tripping of the Gree air conditioner

Updated on Financial 2024-03-20
12 answers
  1. Anonymous users2024-02-07

    It may be a problem with the air conditioning line or your home circuit, this situation requires Gree professional service personnel to come to the door for inspection and troubleshooting, please click on the self-service report or call Gree National Unified After-sales Service **4008365315 feedback your needs and suggestions.

  2. Anonymous users2024-02-06

    Air conditioner leakage, air conditioner short circuit, air conditioner line reversed.

    Air conditioner leakage, that's the reason for the air conditioner: because it is turned on for a period of time before tripping, it means that the entire line and the air conditioner have no leakage at the beginning. If it is caused by leakage, then it is very likely that the condensation of the air conditioner during operation causes the air conditioner to leak.

    However, qualified air conditioner condensate will not cause air conditioner leakage (which is very difficult).

    A short circuit in the air conditioner will also cause the air conditioner to trip as soon as it is turned on; Check to exclude; Timely repair or replacement.

    If the air conditioner line is reversed, the temperature of the switch will rise, resulting in a decrease in the amount of current allowed through the switch. When the switch is hot enough, then the switch trips.

    The air conditioner switch is damaged and the air conditioner trips as soon as it is turned on: replace the switch in time, then there should be a leakage and overcurrent protection switch. This type of switch trips for the reasons of the air conditioner tripping due to excessive current

    There is leakage in the line behind the switch or the current flowing through the switch is greater than the maximum value of the switch.

  3. Anonymous users2024-02-05

    Hello, your electricity needs to be increased, ask the electrician to help you take a look.

    1. The air switch used in the air conditioner is out of order or damaged: the air switch is used for a long time, and there is aging or passivation, which leads to the wrong tripping of the air opening on the one hand; It will also cause the air conditioner to leak and not be able to respond in time, which is more dangerous, and it is recommended to replace it in time.

    2. The starting current of the air-conditioning compressor is too large and exceeds the rated range of the protection device; Replace it in time so as not to affect the normal use of the air conditioner.

    3. The insulation performance of the metal components of the Gree air conditioner decreases or the insulation layer is damaged, resulting in leakage, which causes the Gree air conditioner to trip as soon as it is turned on; Check and eliminate in time to avoid leakage accidents.

    4. Air conditioner short circuit; Measure the input line resistance of the air conditioner; Detect whether it is a direct short circuit; Whether the motor of the outdoor unit is short-circuited with the compressor.

  4. Anonymous users2024-02-04

    Hello! There are two possibilities, one is that the wiring at home is aging and cannot load high-power electrical appliances, and the other may be that the line is short circuit or leakage.

  5. Anonymous users2024-02-03

    The air conditioner trips as soon as it is turned on, and there should be a short circuit or leakage fault, mainly depending on whether the air switch trips or the leakage protection switch trips.

  6. Anonymous users2024-02-02

    The voltage is unstable, or there are too many electrical appliances used to load it.

  7. Anonymous users2024-02-01

    1. If the power of the air conditioner exceeds the power of the wire, it is very likely that this problem will trip as soon as it is running. 2. There is also a leakage of the air conditioner wire, and the leakage protection switch will trip immediately for protection, which will cause the problem of tripping when the air conditioner is running. 3. After the power supply problem is eliminated, it is very likely that the internal parts of the air conditioner are faulty or damaged, which will cause this tripping problem.

    Suggested workaround:

    1. If it is caused by the power of the wire, the power cord of the air conditioner needs to be unplugged first, and after unplugging, it is necessary to contact professional maintenance personnel to test the circuit and power supply, and repair it according to the problem to solve it.

    2. Since there is a leakage protection switch inside the air conditioner, once the leakage problem occurs in the air conditioner, the leakage protection switch will be opened, so if this problem is caused, it is recommended to contact professional maintenance personnel in time to check the cause of leakage for maintenance.

    3. The air conditioner may be used for a long time, because the internal parts have been damaged, at this time, it is recommended to contact the professional maintenance personnel of the air conditioner in time, check clearly before the parts can be replaced or repaired, and then try to start after reinstallation, which should solve the problem of tripping.

  8. Anonymous users2024-01-31

    The reasons why the Gree air conditioner trips as soon as it is turned on are as follows.

    1. It may be caused by the instability of the voltage at home or the short circuit of the line, and the air conditioning compressor cannot start normally.

    2. It may also be caused by an abnormality in the leakage protector at home.

    3. The four-way valve of the air conditioner has a blow-by, which makes the high and low voltage of the air conditioner have problems, and when the current rises sharply, the air conditioner will trip as soon as it is turned on.

    4. It is also possible that too much dust has accumulated on the condenser fins inside the air conditioner, which makes the air conditioner trip due to high heat load.

    1. You can first use the wiring board to reinstall a thick sail socket for the air conditioner, and then try to start it. If there is still tripping, it means that the air conditioner is faulty. You can also unplug the power plug of the air conditioner first, and then send the gate up, if you can send it up, it means that the air conditioner has a fault, then you need to check in detail whether the air conditioning line has a short circuit, if it can't be sent, it means that the home line is abnormal.

    2. If the insulation skin of the air conditioning line is damaged, then the insulation performance of the wire will deteriorate, and when the air conditioner is turned on, there will inevitably be a tripping phenomenon, which is an automatic power-off protection measure automatically initiated by the leakage protector at home in order to protect the electrical appliances, in order to prevent the air conditioner from burning out due to excessive current. At this time, it is necessary to use a multimeter to detect the socket, and if the wire is broken and short-circuited, it is necessary to ask an electrician to help detect and replace it.

    3. If the socket of the air conditioner does not have a grounding wire or the wiring position is loose, it will also cause the air conditioner to trip as soon as it is turned on. If there is no abnormality in the socket, you need to check the compressor of the air conditioner in detail to see if there is any poor contact, and if so, you need to ask a professional to help repair it.

    The above is a detailed introduction to what happens when the air conditioner rock is turned on, I hope it can help friends in need.

  9. Anonymous users2024-01-30

    The Gree air conditioner trips as soon as it is turned on may be caused by the following reasons:1Circuit Fault:

    The air conditioner circuit is faulty, causing excessive current, triggering fuse trip protection. 2.The supply voltage is unstable:

    The voltage of the circuit where the air conditioner is located is unstable, which may be due to the aging of the power supply line or large voltage fluctuations. He Peng 3Air conditioner internal fault:

    The internal circuit or electrical components of the air conditioner are faulty, resulting in excessive current, triggering the fuse trip protection. 4.Air conditioner overload:

    The air conditioner is overloaded, exceeding the rated power of the air conditioner, resulting in excessive current, triggering the fuse trip car protection. If the Gree air conditioner trips as soon as it is turned on, it is recommended to contact the air conditioner maintenance personnel of Zhuzen Silver for inspection and maintenance.

  10. Anonymous users2024-01-29

    It is possible that the power of the air conditioner is too high. Super cautiously learned that the width of the family's forehead is related to the fixed current, so it will trip, one possibility is that there is a short circuit inside the air conditioner. You can first see that there is no problem with the air conditioning.

    If the air conditioner is fine, then you can change the air switch.

  11. Anonymous users2024-01-28

    1. It may be a circuit board.

    Varistor above.

    Broken, the voltage is unstable and the varistor is broken, and it trips from the song. 2. There may be a problem with the outdoor fan or compressor. 3. It may be an air switch.

    Fault. Suggested workaround:

    1. If it trips in a few seconds as soon as it is turned on, it may be that the varistor on the circuit board is broken, the voltage is not stable and the varistor is bad, or the circuit board has signs of short circuit or the cross-current fan motor is faulty, then the resistor on the circuit board needs to be replaced.

    2. The reason for the air switch, because the carrying current will not reach the nominal value after the air conditioning switch fails, please do not deal with it yourself, it is best to find a professional air conditioner maintenance personnel to deal with it. Wild guess liquid.

    3. When the air conditioner is started, the instantaneous current is too large and the air conditioner trips as soon as it is started, and the high-power air conditioner protection device needs to be replaced.

    4. The air conditioner may also trip due to overheating, which can detect whether the radiator of the outdoor unit of the air conditioner is too dusty and whether the heat dissipation effect is good.

    5. Low-pressure relay action, refrigerant in the refrigeration system.

    If it is not enough, check the cause of the insufficient refrigerant in the refrigeration system, and eliminate it to restore the suction pressure to normal pressure.

    6. If the button on the temperature controller is not dialed to the proper position, adjust the button on the temperature controller to the required position, that is, adjust it according to the temperature required by the air-conditioned room.

  12. Anonymous users2024-01-27

    1. It may be due to the failure of the power supply connected to the air conditioner, or the voltage is unstable, it is easy to cause the problem that the air conditioner always trips. 2. It may also be because the power of the air conditioner is too large, and the power of the power supply is not enough, and there will always be a trip phenomenon in the process of operation. 3. If there is a short circuit inside the air conditioner, and the control circuit is faulty, it can also cause the air conditioner to always trip.

    Suggested Treatment:

    1. First of all, it is necessary to see if there is any abnormality in the power supply under the detection of Hongyu professional personnel, if it is because of the power supply, it is recommended to repair or boost the circuit under the operation of professionals, and after the repair, the circuit is normal, and then turn on the air conditioner again, you can resume normal use.

    2. If it is caused by the circuit failure or short circuit inside the air conditioner, it is recommended to contact professional air conditioning maintenance personnel in time, or you can make an appointment for door-to-door service.

    3. If the problem is caused by the excessive power of the air conditioner, you only need to find the power supply of the air conditioner again, and connect it in the state of matching the power of the power supply and the air conditioner.

Related questions
19 answers2024-03-20

1.The drain is clogged. The most common cause of dripping water in an air conditioner's indoor unit is a problem with the drain pipe. >>>More

22 answers2024-03-20

Gree air conditioner. The external machine does not work due to the following reasons: >>>More

8 answers2024-03-20

The reason why the air conditioner at home trips as soon as it is turned on: it may be a problem with the main engine of the air conditioner, as soon as it runs to refrigeration, it will be short-circuited inside, generating high-voltage current, resulting in tripping. >>>More

21 answers2024-03-20

1. The fuse in the special circuit of the air conditioner is blown out, or the contact of the power switch is poor, or the power supply is out of phase. At present, many families only use one power supply, which will cause abnormal power supply due to the abnormal operation of other electrical appliances. >>>More

18 answers2024-03-20