-
Laser rangefinderInstructions for use are as follows:
1. Load the 9V battery into the battery installation place according to the correct polarity.
2. Press the "Transmitter Button" to turn on the internal power of the rangefinder! The rangefinder is visible through the eyepiece in a state of readiness for measurement.
3. By pressing and holding the "mode button", you can directly switch the unit Zen rotten group: meter (m) or yard (y).
4. After turning on the power and switching the unit, Liqin passes the "internal LCD screen" in the rangefinder eyepiece.
Aim at the object being measured. Tap the "Transmit button" and the measured distance will be immediately displayed on the "Internal LCD".
5. The user can pass the "2 diopters.
Regulator" to adjust the clarity of the object being measured, near and far. The closer the object is aimed, the "diopter adjuster" rotates to the left; Conversely, the farther you aim at the object, the "diopter" rotates to the right.
6. Every time you press the mode button, you can change the mode. When the power is turned on, it is in the last usage mode.
7. Press the ON Adjust button, the mirror displays +, align the center circle with the target to be measured (it cannot be a target that absorbs strong light such as glass), and the mode is generally set to the standard state.
Press the ON Adjust button again for about 3 seconds, the target distance will be displayed, and if it is not applicable, it will automatically shut down after 15 seconds.
-
The instructions for the use of the laser rangefinder are as follows:
1. Load the 9V battery into the battery installation place according to the correct polarity.
2. Press the "Transmitter Button" to turn on the internal power of the rangefinder! The rangefinder is visible through the eyepiece in a state of readiness for measurement.
3. By pressing and holding the "mode button", you can directly switch the unit: meters (m) or yards (y).
4. After turning on the power and switching the unit, aim at the measured object through the "internal LCD screen" in the eyepiece of the rangefinder. Tap the "Transmit button" and the measured distance will be immediately displayed on the "Internal LCD".
5. The user can adjust the clarity of the measured object through the "2 diopter adjuster". The closer the object is aimed, the "diopter adjuster" rotates to the left; Conversely, the farther you aim at the object, the "diopter" rotates to the right.
6. Press the mode button once to change the mode. When the power is turned on, it is in the last usage mode.
7. Press the ON ADJUST button, the mirror displays +, align the center circle at the target to be measured (not a target that strongly absorbs light such as glass), MODE is generally placed in the standard state, and continue to press the ON ADJUST button again for about 3 seconds, the target distance is displayed, if it is not applicable, it will automatically shut down after 15 seconds.
-
1. Single measurement.
After powering on, it will enter the single measurement mode by default, press the READ button to emit the laser to select the measurement point, and then press the READ button to display the measurement data at the bottom of the screen.
2. Continuous measurement.
In the mode to be measured, press and hold the READ button to enter the continuous measurement state, and the auxiliary display area on the screen will display the size peak value during the continuous measurement.
3. Area measurement.
Press. <>
button once the screen will display a rectangle, according to the prompt to measure the length and width, the cavity machine automatically calculates the area.
4. Volume measurement.
The volume can be measured by pressing the button twice, and the length, width and height can be measured according to the prompt, and the machine will automatically calculate the volume.
5. Pythagorean measurement shows the first example.
Press. <>
The key can be measured in Pythagorean, and the hypotenuse distance and horizontal distance are measured according to the prompt, and the vertical distance is automatically calculated.
6. Pythagorean measurement example 2.
The button can be measured in Pythagorean, and the hypotenuse distance and horizontal distance can be measured according to the prompt, and the machine automatically calculates the vertical distance between the two hypotenuses.
7. Pythagorean measurement example three.
The button can be measured in the Pythagorean, and the hypotenuse distance and horizontal distance are measured according to the prompt, and the machine automatically calculates the vertical distance.
8. Triangular area measurement.
The button can be measured in the Pythagorean, and the three sides of the triangle can be measured according to the prompt, and the machine calculates the area.
9. Datum setting.
Press. <>
The key can be selected to the reference position, which is convenient for measuring the circle in various environments.
-
1.Adjust the sight of the rangefinder eyepiece so that the objects in the field of view are clear. 2.
Press 'on adjust.''button, the mirror shows '+'3Align the center circle with the target to be measured, and the 'mode' is generally set to the standard state. 4.
Press 'on adjust' again'button for about 3 seconds, the target distance is displayed, and if the ruler is not applicable, it will automatically shut down after 15 seconds. 5.Each time you press the 'mode' button, you can change the high-change mode.
When the land rental power is turned on, it is in the last usage mode).
-
Summary. Alternatively, you can proceed as follows:
2. Two ways:
1) When the phone is turned on, go to the phone settings - storage - menu to the bottom, and click to restore factory settings.
2) Turn off the phone completely, then press and hold the "Volume Down button" + "Power button" at the same time until the Hboot interface appears on the phone, then let go, press the Factory Reset item in the volume selection page, and press the power button to confirm to clear all data and restore to factory settings.
3. After restarting the phone, the phone will be restored to factory settings.
How to restore the sndway rangefinder to factory settings.
Hello! Glad to answer for you, you can press the clear button to return the instrument to normal mode, which means that it will return to zero. The Clear key can be used to measure before the calculation or after the permeability measurement is calculated.
In a function (area or volume), you can use the clear key to go back to the previous command to cluster the branch and make a new measurement.
Or you can follow the following procedures: 1. Prepare the data in the mobile phone (SMS, lost contacts, ** applications, etc.), and then please follow the steps below to restore the factory settings: 2. Two ways:
1) When the phone is turned on, enter the phone settings - storage - menu to the bottom, and click to restore factory settings. 2) Turn off the phone completely, then press and hold the "Volume Down button" + "Power button" at the same time until the Hboot interface appears on the phone, then let go, press the Factory Reset item in the volume selection page, and press the power button to confirm to clear all data and restore to factory settings. 3. After restarting the phone, the phone will be restored to factory settings.
-
1. Touch the Start Measurement button to turn on the rangefinder.
2. Replace the measurement datum edge with the addition or subtraction key as needed (only valid for a single measurement), a - leading edge; b—instrument bracket; c—trailing edge.
3. Aim at the target with the laser, touch the start measurement button again, and record the measured value.
4. After the measurement is completed, press the clear button until the initial screen appears. Press the plus and minus keys at the same time to turn off the rangefinder.
In the case of no work command in seconds, the rangefinder will automatically shut down.
6. The range finder can be self-calibrated by using the standard distance, and can be corrected through the offset menu item.
Problems that need to be paid attention to when using the laser rangefinder: the laser rangefinder cannot be aimed at the human eye to measure directly to prevent harm to the human body. At the same time, the general laser rangefinder does not have waterproof function, so it is necessary to pay attention to waterproofing.
The latest Leopold laser rangefinder in the United States, because it is mainly suitable for outdoor hunting enthusiasts in the United States, has the advantage of being waterproof and anti-foggy, and is equipped with jungle trees and foliage.
Transmissive: l = c t
Reflective: l=1 2c t >>>More
Probably not, my mom and my mom's colleagues have done it, at first they have to wear an eye patch for a day, and then they ask for eye medicine, they have been doing it for a long time, and there is nothing uncomfortable, so let's take some information: >>>More
The difference between 3D laser marking and traditional 2D laser marking is that 3D laser marking is suitable for laser marking of various metal or non-metal products on three-dimensional surfaces. With the rapid development of laser technology, laser processing is also gradually changing, and in order to meet the processing needs, 3D laser marking technology is now gradually rising. Compared with 2D laser marking, 3D laser marking can be laser marked quickly for uneven surfaces and irregular shapes, which not only improves the processing efficiency, but also meets the individual needs of the current processing. >>>More
At present, the laser cutting industry has spread all over the country, but the power of laser cutting machine brands and models is numerous, so we must first understand our own needs and then choose the right laser cutting. >>>More
It takes about a month after laser birthmark removal, and it can be recovered after a few courses of treatment. However, after surgery, you should eat less plain and dark foods such as soy sauce, and try to avoid sunlight, especially not exposure to the sun, and sunscreen when going out, otherwise it may leave pigmented spots. It is necessary to pay attention to post-operative care, and the quality of care is directly related to the length of recovery time.