Not all Perkins diesel generator sets are created equal. The technical parameters of different units such as power and configuration of the unit are different! Therefore, it depends on what kind of unit it is.
Perkins diesel generator sets have superior performance and reliability, provide a variety of stable backup and high-quality power, and can be applied to continuous load working conditions.
When choosing Perkins diesel generator set, users must pay attention to the choice of unit brand, configuration and unit power, and choose according to specific work needs, so that the selected unit will meet the work requirements.
-
To understand the technical parameters of a Perkins generator, do you understand the power of the unit? Do you know the technical details of the unit? Let's take the 500kw Perkins generator as an example
Model: HQP500GF
Output power: (kw).
Primary: 500 625
Spare: 550 690
Current: 900
Fuel consumption rate (g: 214
Unit size (mm l w h): 3380 1500 2100 Unit weight (kg): 4706
The reasons for choosing Perkins engines: 1. The diesel engine is produced by Caterpillar in the United States and Rolls-Royce in the United Kingdom; 2. The engine adopts European and American technology, good quality 3, low fuel consumption, stable performance, convenient maintenance, low operating cost and low emissions; 4. Clean and quiet, the noise level is kept at a low level; 5. The engine provides a two-year warranty period and the quality is reliable.
-
Summary. Hello, 160 kW or so, because.
The rated power of the 200kw diesel generator set manufactured by the regular manufacturer is 200kw, that is, the common power is 200kw, and the rated current is 360a. That is to say, the power of the diesel generator set is 200kw when it is running, considering that the diesel generator set also has a power factor, generally speaking, the load driven by the diesel generator set is generally about 160kw.
How much load can Perkins 220kw diesel generator set drive?
Hello, about 160 kilowatts, because the rated power of the 200kw diesel generator set manufactured by the regular manufacturer is 200kw, that is, the common power is 200kw, and the current is 360a. That is to say, the power of the diesel generator unit is 200kw when it is running, considering that the diesel generator set also has a power factor, generally speaking, the load driven by the front group of the diesel generator family is generally about 160kw.
Have a great day! Happy every day
-
Kiss! I'm glad I answered for you<>
The 1200 kW Perkins diesel generator set on the market is generally between 700,000-1,200,000. Specifically, you need to ask the manufacturer or distributor according to the actual situation. The 1200 kW Perkins diesel generator is a diesel generator capable of providing a power output of 1200 kilowatts (or megawatts).
The generator uses Perkins as a power source and is equipped with a generator head and control system, which can be used as a source of power for commercial, industrial and agricultural sectors**. These generators are typically diesel powered and are efficient, stable and reliable, and can operate in many different environments. I hope mine can help you
-
Hello, I'm glad to answer for you, the ** of the 1200 kilowatt Perkins diesel power generation unit varies according to the model, power, Songzhi configuration, manufacturer, etc. The 1200 kilowatt Perkins diesel generator set can be roughly divided into three gears: high-end models, more than 270,000 yuan, mid-end models, around 200,000 yuan, and low-end models, less than 150,000 yuan.
In addition to this wild land, it should be noted that due to the large market volatility, the ** of the 1200 kW Perkins diesel generator set will also be affected, so it is best to consult the local manufacturer before purchasing to get more accurate ** information. <>
-
1. Perkins diesel generator set voltage regulation rate, frequency regulation rate. The voltage regulation rate is within + under the following conditions: from no-load to full-load, the frequency is synchronized, and the power factor is between; Random frequency fluctuation, from no-load to full-load; Operate under arbitrary stable load conditions; The maximum value of Perkins diesel generator set is from chiller to heat+; Rotational speed** not exceeded.
2. Perkins diesel generator set voltage waveform, unit process. The circuit is open, and the maximum total waveform is distorted; Special welded chassis, built-in shock absorbing pad, overall hoisting and hoisting; Three-phase balanced load, the maximum total waveform distortion is 5%; The standard configuration chassis is a fuel tank with continuous operation for 8 hours, double flexible rubber fuel connection pipes, chassis fuel tank matching level gauge, and sewage blockage.
3. Perkins diesel generator set** influencing factor. High-grade paint coating, wear-resistant and hanging-resistant, bright and durable, less than 50; A set of installation manuals, operation and maintenance manuals, parts manuals and circuit diagrams; **Harmonic factor (THF) is less than 2%, in accordance with BS4999 40 part of the standard ISO3046, ISO8528, BS4999, BS5514, BS5000PT99, AS1359; Electromagnetic Influence UE5100, VDE0530; BS800 compliant, VDE class between G and N.
-
Your question is too extensive, and you'd better determine which power segment's technical parameters and what kind of configuration to make, so that you can get accurate technical parameters.
-
The basic parameters include the following, and the electrical performance indicators of the unit can be found in GB T2820:
1. The rated power P(kW) or S (KVA) :p is the active power output of the generator (P= 3ivcos), and S is the apparent power of the generator (S= 3iv).
2. Rated voltage V: Generally marked with 400V 230V, that is, the three-phase rated voltage is 400V, and the single-phase rated voltage is 230V.
3. Rated frequency f: the national standard stipulates that the power frequency unit is 50Hz, and the intermediate frequency unit is 400Hz.
4. Rated current I: refers to the current that the stator winding of the generator is allowed to pass for a long time.
5. Rated power factor COS
hysteresis for three-phase generators), hysteresis for single-phase generators) and.
6. Rated speed n: corresponding to the speed of the generator rotor under the rated power. At present, the three-phase generator set is mostly used 1500r min, and the single-phase generator set is generally used 3000r min.
7. Rated excitation current IR: the DC current passing through the excitation winding when the alternator is under rated load conditions.
8. Rated excitation voltage vf: refers to the DC voltage added to the excitation winding when the rated excitation current is rated.
9. Excitation mode: the power supply that provides the excitation current, the one from the outside of the generator is called other excitation, and the one from the generator itself is called self-excitation. Other excitation and self-excitation are collectively referred to as excitation methods.
The other excitation mode is divided into two types: parallel excitation and compound excitation. The self-excitation method is divided into various types, such as salient pole reverse sequence magnetic field excitation, AC exciter excitation, reactance phase-shifting phase compound excitation, resonant phase complex excitation, third harmonic excitation, and thyristor excitation.
-
Perkins Diesel Generator Set Introduction (Rolls-Royce Diesel Generator Set) was founded in 1932 with an annual output of nearly 400,000 engines. The diesel and natural gas fueled engines are widely promoted and applied in various industries because of their economic, reliable and durable advantages. As one of the world's A-certified companies, Perkins diesel generator sets have truly gone international, and today Perkins has production offices in 13 countries and a global service network of more than 4,000 distribution points and service centers.
In the field of power generation, diesel generator sets covering 7kw-1811kw have the advantages of excellent performance, reliability, durability and so on.
In 1998, Perkins became a member of the Carter Group as a member of Chrysler Corporation. Perkins entered the Chinese generator market late, but after entering the Chinese market, it was accepted by customers at a very fast speed, and quickly occupied a part of the market share, and made remarkable achievements in the generator set market.
Komler Power believes that Perkins generator sets are affected by many factors, in addition to the power, brand and configuration of the unit itself, it will also be affected by market demand, weather and other factors. When two Perkins diesel generator sets are configured with the same configuration, the power of the unit is different for different units.
When the power of two Perkins diesel generator sets is the same, the unit configuration is different for different units.
When choosing the unit configuration and power, the user must choose the appropriate power and unit configuration according to the specific work needs.
-
Perkins Perkins was one of the first companies in the world to produce engines.
-
Introduction to the Perkins series.
Founded in 1932 by British entrepreneurs in Peterborough, the British Perkins Engine **** is one of the world's leading engine manufacturers and a market leader in off-highway diesel and natural gas engines from 7 to 2000 kW (5 to 2800 hp). Perkins is trusted by equipment manufacturers for their ability to tailor engines to meet their specific needs.
Reasons to choose Perkins Engines:
1. The diesel engine is produced by Caterpillar in the United States and Rolls-Royce in the United Kingdom;
2. The engine adopts the latest European and American technology and high-strength wear-resistant materials to ensure first-class quality;
3. Low fuel consumption, stable performance, convenient maintenance, low operating cost and low emission;
4. Clean and quiet, and the noise level is kept at the lowest level;
5. The engine can run without failure for up to 6000 hours;
6. The engine comes with a standard two-year warranty, highlighting the manufacturer's absolute confidence in the durability and reliability of the machine.
-
Proper maintenance of Perkins diesel generator sets, especially preventive maintenance, is the most economical maintenance, which is the key to prolong the service life of the generator and reduce the cost of use. Based on this, and with reference to the content of the diesel generator operation and maintenance manual, special working conditions and use experience, different maintenance schedules are formulated. The following Huaquan will introduce to you the daily maintenance and maintenance items of Perkins diesel generator sets.
1. Check the fuel volume of the fuel tank, and observe the fuel tank storage volume, and add as needed.
2. Check the oil level in the oil pan, the oil level should reach the engraved mark on the oil scale, and if it is insufficient, it should be added to the specified amount.
3. Check the oil level of the fuel injection pump governor, the oil level should reach the engraved mark on the oil ruler, and it should be added when it is insufficient.
4. Check the three leaks (water, oil, gas). Eliminate oil leakage and water leakage on sealing surfaces such as oil and water pipeline joints; Eliminate air leakage in intake and exhaust pipes, cylinder head gaskets, and turbochargers.
5. Check the installation of each accessory of the diesel engine. Including the stability of the installation of each accessory, the anchor bolts and the reliability of the connection with the working machine.
6. Check each instrument. Observe whether the reading is normal, otherwise it should be repaired or replaced in time.
7. Check the transmission connecting plate of the fuel injection pump. Whether the connecting screws are loose or not, otherwise the injection advance angle should be recalibrated and the connecting screws should be tightened.
8. Clean the appearance of diesel engine and auxiliary equipment. Use a dry cloth or a dry rag soaked in diesel oil to wipe off oil, water and dust on the fuselage, turbocharger, cylinder head housing, air filter, etc.; Wipe clean or with compressed air.
-
Perkins diesel generator set new unit should be filled with coolant before starting. When filling, the bleed valve of the upper cooling system of the engine should be opened, and the coolant should be slowly added to the engine from the refill port of the cooling tank until no air bubbles are discharged from the bleed valve. The coolant should be filled to the bottom of the neck of the water inlet of the cooling water tank, and should not be overfilled.
Once filled, close the bleed valve and open the cut-off door on the water filter mount to allow the DCA4 additive to mix into the cooling system. The coolant used in the cooling system should be mainly composed of three components: purified water, antifreeze and DCA4 additives, and each liter of coolant contains 50% pure water, 50% antifreeze and 0 5 units of DCA4 additives. The coolant can be used all year round and can be used for two years.
Pure water is purified to avoid limescale formation. Antifreeze refers to ethylene glycol or propylene glycol used in industry, which can lower the freezing point of water and increase the boiling point of water. The concentration of antifreeze should be 40%.
68%, too high or too low concentration will affect the freeze protection of the coolant. In most climates, a 50% concentration of antifreeze is recommended, when the freezing point of the coolant is reached—additives form a protective film on the inner surface of the water system to prevent cavitation and sediment build-up in the liner and body. Before starting the new machine, the oil should be filled through the oil filler.
When filling, the engine should be placed in a horizontal position and pay attention to the change of oil level. After refueling, wait a while and then look at the oil level on the oil scale, that is, the oil level you see when the oil has flowed into the oil pan is the correct value. Each oil filter should be topped up with clean oil before it can be installed on the engine.
When choosing an oil, you should choose the right viscosity and meet the American Petroleum Institute (AH) performance grades. Perkins diesel generator sets require the use of multi-grade viscosity oils, as multi-grade viscosity oils are suitable for a wide range of operating temperatures and consumption rates are about 30% lower than single-grade viscosity oils. The performance grade of the engine oil represents the level of the oil additives, for the heavy-duty engine, the main protective role is the additives in the engine oil, because the additives will gradually be consumed with the continuation of time, only the selection of sufficient grade of oil, in order to ensure that the engine can be reliably protected throughout the oil change cycle.
Perkins recommends using an oil that meets the following standards: if the ambient temperature is higher than -5, use a 15W-40CF4, CG4, CF4 SG, or CG4 SH grade oil; When the ambient temperature is lower than -5, use 10W-30CF4, CG4, CF4 SG, or CG4 SH grade oil. B and C series engines must be manufactured with CF4 SG or CG4 SH oil.
Perkins recommends the use of "Blue Supreme" engine oil, this brand of engine oil has a viscosity index of 15W-40, a performance grade of CG4 SH, and the applicable agent formula is completely formulated in accordance with the unique performance characteristics of Perkins engine, which can effectively extend the oil change interval of the engine and reduce the oil consumption rate.
What are the things to pay attention to when buying a diesel generator? >>>More
The basic structure of a diesel generator is composed of a diesel engine and a generator, and the diesel engine is used as a power to drive the generator to generate electricity. >>>More
The maintenance cost is low, the accessories are easy to buy, and the domestic neutral price is high!
The difference between Huaquan silent generator set and general generator set is that the silent generator set is added with a very effective sound cancellation device, which is mainly used in homes and places with high requirements for noise control. Our company's silent generator set has the characteristics of small size, light weight, compact structure, beautiful sound insulation cover, simple disassembly and assembly, easy operation of the unit, excellent performance and reliable operation. It is mainly used in hospitals, hotels, communication industries and other fields. >>>More
Silent diesel generator set introduction: a kind of rainproof and dustproof, double-layer fuel tank silent diesel generator set, involving diesel generator set, including the unit chassis, and the engine and generator installed on the unit chassis composition, in the engine and generator outside the metal shell, belongs to the utility model silent diesel generator set. >>>More