Haier inverter air conditioners have a buzzing sound

Updated on home 2024-04-13
19 answers
  1. Anonymous users2024-02-07

    Haier has been getting better and better in recent years.

    Relying only on the name to eat, the configuration of parts is getting worse and worse.

    If it's a noise from the internal machine, it's nothing more than a runner or a wind barricade.

    The deformation of the runner causes the rotation to produce vibrations and make sounds.

    The wind barrier blades fall off and the vibration produces noise.

    If it is an external machine, the problem of the blade is also very common, deformation, breakage, and unbalance when rotating, which are the most common problems of Haier.

    It's not a big problem, but it's annoying.

  2. Anonymous users2024-02-06

    This is the sound of the transformer, which is a bit like the sound of an electric current, and it is said to be a problem with the transformer.

    The one I just bought hangs up like this, I don't use it, as long as I plug it in, it has this sound.

    Today, a master came to the door, can not find the problem, just searched on the Internet, saw, some people say that this is the transformer core is not tight or the transformer is not fixed well to produce resonance

  3. Anonymous users2024-02-05

    1.The air conditioner is not properly installed.

    2.There is a defect in the fan or drum fan blade of the internal machine.

    3.You can request to return or exchange the whole machine.

  4. Anonymous users2024-02-04

    Call 4006999999 and ask the installer to adjust it, it should be the resonance generated by the installation, or it may be sent by the stepper motor. Let them check it out! Remember to ask them to come at a time when it must be quieter in your house, otherwise the small sound will be hard to hear!

  5. Anonymous users2024-02-03

    First of all, I don't know if the sound you are talking about is coming from the internal machine or the external machine, if it is an external machine, there are two possibilities: one is that the fluorine is overdosed, and the other is that there is a problem with the compressor.

  6. Anonymous users2024-02-02

    Transformer. This is also the case if the condenser is loose.

  7. Anonymous users2024-02-01

    My Haier is also a problem with it, and it hasn't been solved yet.

  8. Anonymous users2024-01-31

    What's going on with the buzzing sound of the Haier air conditioner, hello, the reason may be that the wind speed of the air conditioner is relatively large; The panel of the air conditioner is loose, and it will produce a lot of vibration when it is running; The copper tube is connected to the indoor chassis and is not fixed, resulting in resonance; The noise value of the compressor is larger than that of the substrate during operation; The installation of the indoor unit ignores the firmness. The details are as follows: 1. The wind speed of the air conditioner is relatively large, so it is normal for the sound of its external unit to slowly change and be weak.

    2. The panel of the air conditioner is loose, and there will be a lot of vibration when it is running. 3. The copper tube is connected to the indoor chassis, because it is not fixed, which will produce resonance. 4. The noise level of the compressor is relatively large during operation, which will also affect the large noise of the air conditioner.

    5. Ignoring the firmness of the installation of the indoor unit will cause the copper pipe connected to the internal and external units to be affected and cause vibration and noise. I hope my answer is helpful to you, and finally I wish you good health and a happy mood again! <>

  9. Anonymous users2024-01-30

    First of all, it is necessary to clean the filter of the air conditioner frequently, if the filter screen of the air conditioner is dirty, it will make the noise of the air conditioner become louder, the wind sound is low, and the wind speed of the air conditioner cannot be improved; Check the air conditioner cooling fan again: check whether the air conditioner fan blades are on the protective net, the air conditioner fan is loose, and tighten the fan blades to reduce the noise if the fan blades are not damaged.

  10. Anonymous users2024-01-29

    The reason why the air conditioner is buzzing:

    1. The pressure of the high-pressure pipe in the air-conditioning system is too high.

    2. The condenser is too dirty and the heat dissipation is not good.

    3. The expansion valve is blocked, and the pipeline generates high pressure.

  11. Anonymous users2024-01-28

    Hello, happy to answer your questions. If it's noisy, there's a problem. Reason:

    If the bracket installation level of the external unit is unstable or the fixing screws of the combined bracket are not tightened and cause deformation, it will cause the air conditioner to be placed unevenly, and the air conditioner will be noisy during the operation. Solution: Rearrange the air conditioner bracket, adjust the position of the air conditioner to ensure that it is placed horizontally, and tighten the screws of the air conditioner fixing bracket.

    Hope the answers help you.

  12. Anonymous users2024-01-27

    The buzzing inside the air conditioner is a problem with the fan system. The fan blades should be inspected for dirt accumulation and lubrication system.

  13. Anonymous users2024-01-26

    When the air conditioner is in use, it hums because the compressor of the air conditioner is running, so it produces a humming sound.

  14. Anonymous users2024-01-25

    It's very common for air conditioners to have abnormal noises, usually condensation, and all kinds of strange sounds, which may not be able to get it right.

  15. Anonymous users2024-01-24

    The buzzing sound of the air conditioner is due to the air outlet of the air conditioner, especially the higher the wind speed, the louder the noise. The main noise** of the air conditioner is the air outlet of the air conditioner. When the air conditioner is turned on at a greater wind speed, the noise level of the air conditioner will definitely increase gradually, which is one of the main noise values of the air conditioner**.

    When using an air conditioner for a long time, due to various reasons, the air conditioner panel.

    Easy to loosen. In this way, the vibrations generated by the operation of the air conditioner will cause the panels to rub against each other, creating noise.

    Explanation of the air conditioner

    1. Air conditioning compressor.

    Poor performance, low-frequency vibration hum during operation, can be used to adjust and replace the press.

    2. When the air conditioner is started or stopped, it is normal for the plastic parts of the internal unit to expand and contract due to temperature changes.

    3. The outdoor unit of the air conditioner is too dirty, or there are foreign objects in the case, which rub against the fan and cause noise; Cleaning up foreign objects is fine.

    4. Caused by parts, the common is that the compressor cylinder or compressor starting capacitor is damaged, and the damaged spare parts can be replaced.

    5. When the fan is running, it rubs against the outer wall, and the distance between the fan and the outer wall should be adjusted in time. Alternatively, it is also possible that the fan is stuck and is given to the air conditioner fan.

    Add some lubricating oil to the shaft to ensure that the fan rotates smoothly.

  16. Anonymous users2024-01-23

    Haier air conditioner has a buzzing sound, what's going on, hello dear, first, friction noise, the reason for the noise of the external unit of the air conditioner may be that the fan of the external unit rubs against the outer wall of the external unit during the operation, and the resulting sound, or there is too much debris in the external unit, and the noise caused by friction between the external fan and the external unit. Solution: Adjust the distance between the fan and the outer wall of the air conditioner in time, if the air conditioner is stuck, add a little lubricating oil to the fan shaft to ensure that the fan rotates smoothly, and clean up the air conditioner in time if there is too much debris on the limbs.

    2. The installation level of the bracket of the uneven outdoor unit is unstable or the fixing screws of the combined bracket are not tightened and the deformation is caused, which will cause the uneven placement of the air conditioner outdoor unit, and the noise will occur in the process of operation of the air conditioner outdoor unit. Solution: Rearrange the bracket of the air conditioner unit, adjust the position of the air conditioner unit to ensure that it is placed horizontally, and tighten the screws of the empty type adjustment bracket.

    3. The installation of the indoor unit of the resonance air conditioner is connected with the outdoor unit, and the connection between them will also affect the use of the air conditioner and the operation of the outdoor unit of the air conditioner, and the installation of the indoor unit of the air conditioner is not stable enough, and the indoor unit connected by the copper pipe will be affected by the air conditioning compressor when the outdoor unit of the air conditioner is running, resulting in the resonance of the indoor unit. Solution: Adjust the position of the indoor unit, fix the indoor unit of the air conditioner, solve the problem of unstable installation of the indoor unit, and the indoor unit will not resonate with the outdoor unit if the installation is stable.

    Fourth, the air outlet noise is generally the first place of the air conditioning noise is in the air outlet of the air conditioner, the greater the wind speed of the air conditioner opening, the greater the speed of the air conditioning outlet, and its noise will be expanded accordingly. Solution: When the indoor temperature reaches the set value, reduce the wind speed of the air conditioner accordingly, reduce the workload of the air conditioning tuyere, and reduce the noise of the air outlet when the operating speed of the air outlet is reduced.

  17. Anonymous users2024-01-22

    There are several reasons why Haier's air conditioner is loud and dusty:

    1.The installation of the indoor unit or outdoor unit is not smooth, resulting in vibration and noise.

    2.Dust or foreign matter accumulates inside the air conditioner, causing the fan or motor to run poorly, resulting in noise.

    3.Insufficient refrigerant in the air conditioner or failure of the refrigeration system leads to abnormal compressor operation and noise.

    4.The air conditioner blades are deformed or damaged, resulting in uneven air volume and noise.

    Workaround:1When installing, ensure that the indoor unit and the outdoor unit are stable and avoid vibration and noise.

    2.Clean the inside of the air conditioner regularly to avoid dust and foreign objects affecting the operation of the air conditioner.

    3.If the air conditioner is noisy, you can contact a professional maintenance person for inspection and repair.

    4.Regularly check whether the air conditioner blades are deformed or damaged, and replace them in time.

  18. Anonymous users2024-01-21

    <><1. What is the reason for the noise of the air conditioner?

    1. Failure to clean in time.

    If the air conditioner is used for a long time and is not cleaned, it will cause a lot of dust to accumulate on the air conditioner radiator, and the heat dissipation will be blocked, which will affect the normal operation of the air conditioner and cause the air conditioner to hum and rise in noise.

    2. Quality is the key.

    During the operation of the air conditioner, there is a buzzing sound, which may be caused by the quality of the air conditioner.

    3. Air conditioning outlet.

    The buzzing sound of the air conditioner may be due to the fact that the air speed of the air conditioner outlet is too high, resulting in a buzzing noise, and in this case, turning down the fan can solve the problem.

    4. Loosening of the air conditioning panel.

    After the air conditioner is used for a long time, the panel will be loose, so that when the air conditioner is running, it is easy to vibrate, resulting in the buzzing of the air conditioner.

    5. Installation of air conditioning indoor unit.

    When the air conditioner is running, the copper pipe of the outdoor unit is connected to the indoor unit, which will be affected by the compressor at this time, and the indoor unit resonates, resulting in the buzzing sound of the air conditioner.

    6. Air conditioning compressor.

    There was a problem with the aircon compressor and the noise was too loud, causing the aircon to hum.

  19. Anonymous users2024-01-20

    Summary. Hello! There are many reasons why Haier inverter refrigerator has been buzzing, you can check it against 1, the refrigerator is not stable, the noise caused by unreasonable stress, try to shift, adjust, add pads, etc. to make the sound smaller.

    2. The shelf in the refrigerator is loose, the bottles and cans are placed unsteadily, and the buzzing sound caused by vibration. 3. The buzzing sound caused by the baffle plate and water receiving box of the rear compartment of the refrigerator will expand the vibration of the compressor. 4. The buzzing sound caused by the vibration of the compressor operation, the resonance sound caused by the aging of the rubber pad at the foot and the unreasonable stress of the copper pipe in and out.

    5. The wear and tear in the compressor will also make the running sound louder, and the adjustment is ineffective but does not affect the normal refrigeration, and it can only be used on the spot. 6. Some models of the three doors belong to the form of direct air cooling, and the wear and tear of the circulating fan makes the sound louder, and the sound of opening the corresponding door will be terminated, and the small motor of the shaded pole will be used or replaced. 7. For some reason, the heat dissipation is poor, and the compressor operation is sinking due to the rise of exhaust pressure.

    Hello. Hello! There are many reasons why Haier inverter refrigerator has been buzzing, you can check it against 1, the refrigerator is not stable, unreasonable response to the noise caused by hand cavity force, try to shift, adjust, add pads, etc. to make the sound smaller.

    2. The shelf in the refrigerator is loose, the bottles and cans are placed unsteadily, and the buzzing sound caused by vibration. 3. The buzzing sound caused by the baffle plate and water receiving box of the rear compartment of the refrigerator will expand the vibration of the compressor. 4. The buzzing sound caused by the vibration of the compressor operation, the resonance sound caused by the aging of the rubber pad on the feet of the machine, and the unreasonable stress of the copper pipe in and out.

    5. The wear and tear in the compressor will also make the running sound louder, and the adjustment is ineffective but does not affect the normal refrigeration, and it can only be used on the spot. 6. Some models of the three blind doors belong to the form of direct cooling, the wear and tear of the circulating fan makes the sound louder, and the sound of opening the corresponding door will be terminated, and the small motor will be used or replaced. 7. For some reason, the heat dissipation is poor, and the compressor operation is sinking due to the rise of exhaust pressure.

    Hello! There are many reasons why Haier inverter refrigerator has been buzzing, you can check it against 1, the refrigerator is not stable, the noise caused by unreasonable stress, try to shift, adjust, add pads, etc. to make the sound smaller. 2. The shelf in the refrigerator is loose, the bottles and cans are placed unsteadily, and the buzzing sound caused by vibration.

    3. The buzzing sound caused by the baffle plate and water receiving box of the rear compartment of the refrigerator will expand the vibration of the compressor. 4. The buzzing sound caused by the vibration of the compressor operation, the resonance sound caused by the aging of the rubber pad at the foot and the unreasonable stress of the copper pipe in and out. 5. The internal wear and tear of the compressor will also make the running sound louder, and the modulation rubber is ineffective but does not affect the normal refrigeration.

    6. Some models of the three doors belong to the form of direct cooling, the wear and tear of the circulating fan makes the sound louder, and the sound of opening the corresponding door will be terminated. 7. The compressor operation is unstable due to poor heat dissipation and rising exhaust pressure due to some reason.

Related questions
16 answers2024-04-13

The power supply fan can be replaced, but the general repair computer is not replaced, hehe, because, that does not make money, and it is laborious. Hehe.

17 answers2024-04-13

The premise of less electromagnetic emission is to turn the power supply of the AC power grid into DC, and then reverse it into the power supply of the DC motor. Inverter is also a frequency conversion process, but it is smaller than the next. >>>More

5 answers2024-04-13

Inverter air conditioner is not good mainly because of the compressor, simply put, inverter air conditioner is to add a frequency converter to the structure of conventional air conditioning. The compressor is the heart of the air conditioner, and its speed directly affects the efficiency of the air conditioner, and the operating speed of the compressor, the heart of the air conditioner, is adjusted, so as to achieve a reasonable use of energy. When purchasing inverter air conditioners, we should start from brand awareness, reputation and the overall R&D strength of the enterprise, shop around, and then shoot when it is time to shoot.

1 answers2024-04-13

In 2004, Midea cooperated with Toshiba to develop inverter air conditioning technology, and after 5 years of technology accumulation and precipitation, on September 1, 08, it launched five series of more than 10 new DC inverter air conditioners in one fell swoop. According to Zhang Zhiguo, spokesman and marketing director of Midea Air Conditioning, the five series of DC inverter air conditioning products launched by Midea Air Conditioning all use 180-degree sine wave vector control technology, among which Midea Galaxy C180 is the first inverter air conditioner energy-saving certification certificate from China Quality Certification Center (CQC), with the certificate number CQC08701026100. The seasonal energy efficiency ratio is high, and the operating frequency is as low as 15 Hz. >>>More

6 answers2024-04-13

Inverter air conditioning is the future development trend; Its characteristics are beyond the reach of fixed-frequency air conditioners: first, the low-frequency soft start of inverter air conditioners will not impact home appliances and power grids. Second, high efficiency and energy saving refrigeration is fast. >>>More