Does anyone know how to choose LED display in stadiums?

Updated on physical education 2024-04-02
7 answers
  1. Anonymous users2024-02-07

    In general, the safety performance of the LED display screen of the stadium should meet the requirements of the SJ T11141-2003 standard, and the reliability should meet the requirements of the standard. In terms of material selection, it is required to choose polymer materials with good flame retardant performance (including LED module shell, LED module filler, PCB board, power cord sheath, etc.), and at the same time, in terms of power supply design, the LED display screen of the stadium must be supplied separately and meet the requirements of SJ T11141-2003 standard; The construction acceptance of the cable line shall meet the requirements of GB50168 and GB50171; The quality of the project should meet the requirements of GB50303. In addition, the LED display screen of sports events should have smoke detector, lightning protection, automatic fire alarm and automatic screen shutdown functions, and the power distribution cabinet should have overload protection function, leakage protection function and step-by-step power-on function.

    The installation location and quantity of the display screen require that the installation position of the LED display screen for sports events needs to ensure that more than 95% of the spectators with fixed seats in the stadium can be effective, with a wide visual distance and vision. At the same time, it is required that the LED display display content can be easily and clearly seen by the athletes, coaches and referees at the competition site (except for the on-site scoring referees in diving competitions). The maximum sight distance and character height of the LED display are required for outdoor stadiums, and the brightness of the full-color LED display is required to be more than 5000cd square meters; Dual-color display screen of more than 4000cd square meters; Monochrome 2000cd, square meters or more.

    The brightness of the full-color LED display screen of indoor stadiums is required to be more than 1000cd square meters; Dual primary color LED display 300cd square meters or more; Monochrome 120cd square meters or more. At the same time, in terms of character height requirements, each character of the LED display screen of the swimming pool and diving hall with independent building structure is at least higher, and each character of the LED display screen of the swimming and diving hall with integrated building structure is at least higher. <>

  2. Anonymous users2024-02-06

    The LED display around the football field is the fence screen, which is mainly used for commercial advertising and can also play back the wonderful shots on the field. The LED fence screen is made up of a plurality of box screens, the weight and connection of each box are precisely designed to ensure the speed of disassembly and assembly, and a soft mask will be installed on the general box, which can effectively avoid injuries caused by players falling. LED Display:

    Large full-color LED screen. It is more common in the NBA arena, and is used for the best game pictures at the game site, and the slow-motion replay is replayed, so that the audience does not miss any wonderful pictures. Timing scoring LED display competition is generally determined by the score, timing scoring LED display carries the heavy responsibility of calculating the score of the game, it is connected with the timing scoring system of the game, the player's results and related information.

  3. Anonymous users2024-02-05

    Red, green, and blue contribute differently to the color of white. The root cause is due to the fact that the retina of the human eye perceives light differently at different wavelengths. After a large number of practical tests, the following ratios are obtained for reference:

    The simple red-green-blue brightness ratio is: 3:6:

    1. The accurate red-green-blue brightness ratio is::: The space is small, the best viewing distance is near, in order to achieve a certain display effect, the point spacing must be reduced, and vice versa. In addition, if it is an outdoor screen, you should also pay attention to the heat dissipation of the screen.

    If the ambient temperature is too high and the heat dissipation is poor, the integrated circuit may not work properly, or even be burned, so that the display system can not work normally, so ventilation and cooling equipment must be installed. <>

  4. Anonymous users2024-02-04

    Shenzhen Jiadi Technology **** Stadium LED Display Specifications Stadium LED Display Specifications With the improvement of LED display products in technology and performance, the advantages of the shocking picture are fully displayed, whether it is the application effect or installation and maintenance, the current mainstream large-screen display products can meet the needs of users, and at the same time show extraordinary effects. LED display has emerged in the fields of large-scale exhibitions, stage effects, and high-end displays, and has become more and more widely practical. Today, Fengliyuan Optoelectronics will introduce how the model of the LED display is divided.

    Outdoor led display features and specifications:

    1. Features: large luminous point, large pixel spacing, high brightness, can work in the sun, with windproof, rainproof, waterproof function, suitable for long-distance **, mostly used in bustling street intersections, **dense places such as shopping malls, office building walls, football stadiums and other environments. The life span is more than 100,000 hours.

    2. Specifications: The size of the single module is 32*16cm, composed of 512 straw hat lamp beads with a diameter of 10mm, the point resolution is 10000 m2, the screen brightness (average) is 6500cd m2, and the viewing angle is 120° horizontally, 10° vertically up and 30° down

  5. Anonymous users2024-02-03

    Outdoor is generally a bright P10 (LED is 10mm) or P16 (LED is 16mm) unit board composed of monochrome or two-color and full-color display, these two LEDs are relatively large, so the display is also relatively large, suitable for large screens.

  6. Anonymous users2024-02-02

    Is it a display on the sidelines of the arena?

  7. Anonymous users2024-02-01

    Shenzhen Jiadi Technology **** door head LED display.

    Specification. The indoor screen area is generally from less than 1 square meter to more than ten square meters, the point density is high, and it is used in non-direct sunlight or lighting environment, ** The distance is a few meters away, and the screen body does not have the ability to seal and waterproof.

    Indoor LED display features and specifications:

    1. Features: small luminous point, dense pixel pitch, suitable for close distance, high-quality LED chips, high luminous efficiency, low brightness attenuation, stable display screen and good reliability, mostly used in conference rooms, stages, hotels, station waiting rooms and other indoor environments. The life span is more than 100,000 hours.

    2. Specifications: The size of a single module is composed of 2048 diameter chips, the point resolution is 17220 m2, and the screen brightness (average value.

    800cd m2, viewing angle: 145° horizontal, 120°120° vertical; ф

    The size of a single module is composed of 2048 diameter wafers with a point resolution of 44320 m2; Screen brightness (average): >600cd m2, viewing angle: 145° horizontal, 120° vertically 120° lower.

Related questions
17 answers2024-04-02

From January to April 2008, the retail sales of the accommodation and catering industry in the country reached a total of 100 million yuan, a year-on-year increase, a percentage point higher than the growth rate of the same period last year, accounting for the proportion of the total retail sales of consumer goods, driving the growth of the total retail sales of consumer goods by one percentage point, and contributing to the growth of the total retail sales of consumer goods. >>>More

7 answers2024-04-02

I feel that CFA is still a relatively broad exam, which can basically be applied for by majors that are related to finance, and it pays more attention to the expansion of knowledge, and is not as good as some professional exams in terms of depth. FRM is more math-oriented, but in fact, the difficulty is also good, the difficulty of counting three or four, it is a little more professional than CFA, but the correlation between risk control and your major is not very large. As for which of the two things is better, you need to decide for yourself, it can only be said that FRM is more applicable, CFA is more suitable for people with experience and foundation to supplement and consolidate knowledge, and the exam is more focused on analysis and writing ability. >>>More

6 answers2024-04-02

There is no restriction on the candidate's academic qualifications, and there is no restriction on the industry in which the FRM registration qualification is engaged, and college students in the school also meet the requirements of the FRM registration qualification. >>>More

7 answers2024-04-02

R9S Plus Ways to Delete Text Messages in Batches:

Info - Select the text message you want to delete, swipe left to delete all SMS records with the contact; >>>More

16 answers2024-04-02

That is, every flower has its own meaning.