Yes.
Generally, a 180-liter water heater is full in ten minutes, and a 225-liter solar water heater.
It takes forty minutes to fill up with water at a normal flow rate. If the water level does not change for a long time when the water is connected, you need to check whether the solar filter is blocked.
Things to look out for when using solar energy.
1. Before using solar energy, you must first fill the solar energy with water, and you must water the solar energy in time, if you forget to put on the water, it will let the sun heat be airborne, and after a long time, the solar energy will burst.
2. When using solar energy, be sure to check the snorkel. The ventilation tube can avoid the phenomenon of poor circulation or air blockage in the circulation tube. When the water is served, the ventilation tube can also prevent the water heater from being swollen.
When we are using a water heater, the snorkel can also prevent the solar energy from being deflated due to poor flow of the overflow pipe.
-
Yes. The controller of the solar water heater has the function of automatically stopping the water filling when it is full, whether it is automatic water filling or manual water filling, it will automatically stop water filling when it is full.
If the water cannot be stopped after the water is full, and overflow occurs, it means that the controller is faulty, and the usual fault reasons are:
1. The water level sensor is faulty.
The water level sensor cannot correctly determine the water level, and when the water is full, the controller cannot sense it, resulting in continued water supply and overflow.
This is more common and can be replaced with a water level sensor.
2. The installation position of the water level sensor is incorrect.
Adjust the sensor position.
3. Solenoid valve failure.
It may be that there is debris in the solenoid valve, which causes the closure to be loose and the water overflow.
The solution is to overhaul the solenoid valve.
-
After the solar water heater presses the water, it will automatically stop the water, and the current water heater has a float when the water is full, which directly stops the water from entering. Therefore, after the solar water heater is pressed on the water, it will automatically stop the water when the water is full.
-
Of course, the old water heater has been for a long time, and the self-stop control part is mechanically operated, and it is stuck or rusted or scaled after rusting, or the scale of the electronic detection induction head is stained, resulting in self-stop failure is also normal, in this case, it is necessary to change the electronic water feeder or replace the induction head electronically, or install a return pipe, and manually close the water through the backwater.
-
No, you have to manually stop the water, but the function you said can be realized, and you have to add a solenoid valve and a water level switch yourself.
-
It will be bad after a long time, and the expensive brand is slightly better, but ** is very, very much higher than the miscellaneous brand.
-
Solar water heatersSheung Shui isAutomatic controlThe solenoid valve that uses the water level detection device to control the water inlet will automatically close when the water reaches the set liquid level. If this solenoid valve is not closed, it will keep the water on the water. There are several reasons for this:
1. The water level did not rise to the set water level.
2. The water level detector is damaged.
3. The solenoid valve circuit is damaged.
4. The solenoid valve is damaged.
5. The control board is broken.
In general, it is the problem of water level control that can only be checked and eliminated one by one.
Here are some things you can try:
1: You remove the wiring cover of the controller, find the two wires of the solenoid valve, and use a screwdriver.
Dismantle these two lines. Press the water on button again, if "water on water" is displayed, the water on will no longer be canceled.
It means that the controller and the water temperature are not in place probe without fault, the fault is the solenoid valve, clean the solenoid valve and then connect back to the wire and then on the water, if there is no response, the solenoid valve is broken, replace it with a new one.
2: If after removing the two wires of the solenoid valve, press the water button and still can't display "water", then remove the probe wire on the controller and repeat the original, and then pull out the probe inside the solar water tank on the roof and wipe it.
Reconnect the connector about 1 meter at the probe, turn off the power of the controller once, and then restore the water again, if you still can't get on the water, you have to consider whether to replace the controller.
-
What's the deal with the meter not showing the water level?
-
1. First of all, you need to determine whether you have set up automatic water supply, if it is automatic water supply, then it must show that the water is full; 2. The following kinds of will cause the display to be full: water temperature and water level sensors are so hailstorms; The solenoid valve is faulty, and it cannot be turned off when the water is full; Indoor water mixer failure, cold water and hot water are the same, pretending or touching the slow water state; 3. If you do not set up automatic water feeding, but set up manual water loading, but the water does not show that the water is full, it is caused by the failure of the water level sensing probe, and you only need to replace it, it is recommended to find a maintenance master or buyer.
-
1. First of all, you need to determine whether you have set up the automatic water supply, if it is automatic water supply, it must display the water full state;
It is recommended to take emergency measures to close the main water source first, and it is also recommended to install a manual ball valve device on the water supply line to facilitate maintenance.
2. If you do not set up automatic water supply, but set up manual water supply, but the water does not show that the water is full, it is caused by the failure of the water level sensing probe, and you only need to replace it, it is recommended to find a maintenance master or buyer.
-
1. First of all, you need to determine whether you have set up the automatic water supply, if it is automatic water supply, it must display the water full state;
2. The following kinds of will cause the display to be full: water temperature and water level sensor failure; The solenoid valve is faulty, and it cannot be turned off when the water is full; The indoor water mixer is faulty, the cold water and hot water are the same, and it is in a slow water state;
3. If you do not set up the automatic water on the bucket water, but set the manual water on the water, but the water does not show that the water is full, it is caused by the failure of the water level sensing probe, just replace it, it is recommended to find a maintenance master or buyer.
How to put on water: When adding water to a solar water heater, users should first know what kind of water flow control system is installed on the solar water heater at home
1) If the overflow pipe is installed, the user can first open the stepless control valve water function or water ball valve to replenish the water to the solar water heater, if the overflow pipe installed in the room has water outflow, it proves that the water tank has been full of water, then close the stepless control valve water function or ball valve.
2) If the integrated valve is installed, the user brother or mill should open the water valve, the tap water starts to replenish the solar energy through the water supply and water pipelines, and the water is automatically closed when the water is full, and the water valve is closed when the water is used, and the water switch or mixing valve can be opened.
3) If the water supply function control system is installed, the user first clicks the water supply button of the control system, the solenoid valve is opened, and the solar energy is replenished, and when the set water level is reached, the control system stops feeding the solar energy.
-
The solar water heater keeps running water on itself, which may be due to a broken solenoid valve or a problem with the circuit driving the solenoid valve, causing the solenoid valve to open.
Solar water heater is a heating device that converts sunlight energy into heat energy, heating water from low temperature to high temperature to meet the use of hot water in people's life and production. Solar water heaters are divided into vacuum tube solar water heaters and flat panel solar water heaters according to their structural form, mainly vacuum tube solar water heaters, accounting for 95% of the domestic market share.
-
If it is an automatic control of the water supply, then it is possible that the solenoid valve is broken or the circuit driving the solenoid valve is faulty, causing the solenoid valve to open. If you have installed a manual water supply system, it is possible that you forgot to close the water supply valve or the water supply valve cannot be closed.
-
Reasons for being on the water all the time:
1. The solenoid valve is blocked.
2. If there is no solenoid valve, the water supply valve is blocked.
3. Water pressure problem.
4. There is a water leak in the main engine part, and it flows out on the side.
5. The sensor is broken, and there is a problem with automatic water feeding.
Inspection method: 1. Observe the total tap water meter when the water is on the water to see how fast and slow it turns, and whether it keeps turning.
2. Turn the water down from the solar energy to the hot water side, see if the water is out, the water shows that the solenoid valve is good, on the contrary, the solenoid valve is broken, if the water is different from the tap water speed, it means that the solenoid valve is blocked.
-
Solar energy is full of water and useless and there is no water?
First, make sure that the pipes in the wall are not ruptured and leaking. If there is no leakage, after adding water, the water in the solar tank is still relatively small at night. That is, there is something wrong with your plumbing design.
It must be a water leak that is causing the backwater. That is, when you use cold water at home, the hot water flows into the cold water pipes. Inspect the pipes and install check valves on the main roads of the solar hot and cold water pipes.
There must be something wrong with your controller. See if there's a problem with your water supply or if the controller is broken.
Can anyone tell me that the solar energy is full of water the night before and there is no water at all the next day.
Without? Why? The pipe is not rotten?
If the water pressure is low or there is no water cut, the water in the solar tank will flow backwards.
Most of the time, the controller probes are broken, but there is an extreme case where the solar overflow hole is clogged and the tank is not connected to the atmosphere. Or at night, the temperature in the tank gets low, or the water gets cooler. Outside atmospheric pressure.
Flatten the stainless steel insulation bucket so that there is less water. This condition is not visible from the outside, and you need to pull out a real tube to observe your situation.
My insight: Tsinghua has the best sunlight, fast heating, and long heat preservation time. >>>More
It can be drunk, but it is clean, because the water in the solar energy is always not clean, and the water in it has been heated for a long time, and there is no substance that is needed by the human body, but it will be harmful. >>>More
A set of automatic instruments (including solenoid valves, thermal nano sensors, and meters) for electric heating (installed on the solar host before leaving the factory). >>>More
The reasons are as follows: 1. The built-in probe of the water tank is broken, and it is clear that there is no water in the water tank, but it still shows that it is full. You go to the roof and take out the probe, and if that's still the case, you need to replace it. >>>More
The heat pump unit heating is mainly reflected in: high efficiency, energy saving, environmental protection and safety. No flammable, explosive gases. >>>More