- Galanz air conditioner malfunctioned? With my 7 years of experience in repairing air conditioners, I will tell you how to solve these faults, which should save you a lot of detours.
First: When the air conditioner fails, you can go to the [air conditioner failure** network] to inquire, down to the brand and model of the air conditioner. Universal remote control** query can go to the universal remote control area for inquiry.
When encountering a failure of the air conditioner, we must strictly follow the scientific procedures, and do not act blindly and disassemble at will when the situation is unclear, the fault is unclear, and there are countless in the heart. The consequence of this often amplifies existing faults, increases operating costs, shortens the normal service life of equipment, and leads to early scrapping of equipment.
The air conditioner is not refrigerated or does not refrigerate.
This problem is most common, and the lack of fluorine in air conditioners is the key.
When the machine is turned on, first touch the trachea and judge it by the temperature.
If it is cold, the speed of the fan may be low.
The inner tube scales and dust are cleaned or replaced.
If the inner tube is not considered cool, the thick tube may be flattened.
The return air temperature is not cool, and then touch the intake air to judge.
The air intake is cold and frosty, and fluoride is added to try again.
If the frost slowly disperses, it is a good decision to lack fluoride.
It is not difficult to see the aging of the press, and the lack of exhaust is the key.
Four-way gas is also commonly judged by fluoride collection.
High-pressure scales must be seen to be dirty, and they will be slow to refrigerate.
The air conditioner will be cool for a while, and it will not be cool for a while, and most of them are high-pressure protection.
If you still don't understand, it is recommended that you go to the [Air Conditioning Fault **Net] basic knowledge area and take a look at the maintenance cases to get started.
I hope you get better and better, and the new year will be smooth, all your wishes will come true, you will be healthy, and your family will be happy.
- Finally, I wish you all the best in your work, fix the air conditioner as soon as possible, and live happily ———
-
The outdoor unit is dirty, fluorine, fluorine, gambling, etc., will protect the shutdown, check how the current is.
-
Causes
1. Too much freon causes excessive current, and the current through the inductor on the circuit board is too large, so as to automatically protect the shutdown.
2. The heat dissipation conditions of the host are too poor, which causes excessive current, and the current through the inductor on the circuit board is too large, so as to automatically protect the shutdown.
3. There are two heat-sensitive resistors on the evaporator of the indoor unit, the black one is the indoor temperature induction, and the copper one is the evaporator temperature sensor, and this phenomenon will occur after the resistance is damaged.
Purchase points
A good air conditioner can last up to 10 years, and it is not low. Therefore, you must not be greedy for cheap air conditioners, and you must look at the quality of the product when you buy air conditioners
1 Whether to use a brand-name compressor, the compressor is the heart of the air conditioner, and a good heart is of course important.
2. Whether to use high-quality and high-efficiency heat exchangers, such as hydrophilic membrane trapezoidal aluminum sheets, internally threaded copper tubes, etc.
3. Whether to use unequal distance through the flow blade large wind wheel and stepper motor to drive the wind swing to achieve ultra-quiet design.
4 Whether it is super forced cold (hot) and quickly reaches the set temperature.
-
The air conditioner does not turn is a problem with the air conditioner:
1. The power supply is off. Check the power supply circuit. The indoor unit and the outdoor unit are connected by the AC contactor, and the power supply is also transmitted through this channel, so when the AC contactor is damaged, it means that the outdoor unit and the compressor cannot receive the power supply, and the outdoor unit cannot work normally.
2. Freon leaked. The amount of freon is limited, too much or too little will cause the air conditioner to work abnormally, at this time the self-protection system of the air conditioner, there will be a high-voltage protection automatic switch on and off for self-protection.
3. The condenser is polluted. The outdoor condenser also has its own self-protection system, which is activated when it is not cleaned regularly.
4. Computer board failure. The operation of the outdoor unit is controlled by the computer board, so when the outdoor unit is not running, it may also be the fault of the computer board.
5. The compressor and outdoor unit are burned out. It will also cause the external machine to not function.
-
The possible cause is the phenomenon of the compressor protection device tripping, which means that the high-pressure pressure of the system is too high or the overheating current is too large.
Causes and elimination of high pressure and overheating: too much refrigerant, appropriate reduction of refrigeration dose, poor heat dissipation. Check the condenser pipe for dirt and dirt and clean the condenser. The piping system is clogged. Refer to the pressure gauge to judge, eliminate, and re-process systematically.
Dust and fouling in the evaporator or strainer. It is also possible that the air flow will become smaller, the system pressure and temperature will be unstable, the evaporator or filter will be cleaned, and there may be a lack of fluorine. When there is a lack of fluorine, the compressor discharge temperature will overheat, causing the overheating load protection switch to trip.
-
Galanz air conditioner outdoor unit will stop for a while and turn on your dear, the original 1, may have turned on the automatic mode, when the set temperature is close to the room temperature, it will stop at the set temperature. It creates the illusion of failure when it is turned on and stops, but there is no problem with the actual air conditioner. 2. The voltage is abnormal and unstable.
Compressor overcurrent protection. It is recommended to try a different voltage stabilizing device. 3. The temperature of the indoor coil is too high, resulting in protective shutdown.
When the indoor temperature is 26 degrees Celsius and the outdoor temperature is above 20 degrees, the air conditioner cannot heat normally, which is easy to cause protection. 4. The failure of the indoor fan causes no blowing and protects the shutdown. If the outdoor fan fails, causing serious frosting, defrost is carried out, and the indoor air prevention function is entered.
-
If your Galanz air conditioner stops after more than ten seconds of turning it on, there may be the following reasons:1Thermostat malfunction:
The air conditioner thermostat is a key component that controls the air conditioner to turn on and off and adjust the temperature. If the thermostat fails, it can cause the air conditioner to shut down quickly after it is turned on. It is recommended to contact a professional maintenance personnel for repairs.
2.Lack of fluorine: The internal and external units of the air conditioner do not contain enough refrigerant (fluorine), which will cause the air conditioner to fail to cool or heat normally, and it will automatically shut down soon after turning on.
It is advisable to contact a professional Visceral Therapy professional for examination and fluoride. 3.Circuit Fault:
Faulty circuits may also cause the air conditioner to shut down after it is turned on. For example, short circuit in the power line, power board failure, etc. It is recommended to contact a professional maintenance personnel for inspection and repair.
In short, if you find that the air conditioner is in abnormal condition, it is recommended to contact professional maintenance personnel in time for blind inspection and repair to avoid more serious failures. Sell it.
-
Summary. Dear dear, it's a pleasure to answer your <>
Galanz air conditioner works for 3 minutes, the outdoor unit stops, Galanz air conditioner works for 3 minutes, and the outdoor unit stops because the receiving head is bad or damp and cannot work normally. If the receiving head is broken or damp and cannot work properly, check the transmission of the remote control signal. Aim your digital camera (mobile phone is also acceptable) at the transmitter and press any button to see if there is an infrared signal emitted.
Galanz air conditioner works for 3 minutes and the outdoor unit stops.
Dear dear, it's a pleasure to answer your <>
Galanz air conditioner vibrato works for 3 minutes, the outdoor unit stops, Galanz air conditioner works for 3 minutes, and the outdoor unit stops because the receiving head is bad or damp and cannot work normally. If the receiving head is broken or damp and cannot work properly, check the transmission of the remote control signal. Use a digital camera (mobile phone can also be used) to point at the transmitter, press the Ren Ying blocking button to see if there is an infrared signal sent out.
<>-related expansion: Galanz air conditioning is positioned as "the world's largest air-conditioning specialized manufacturing center", with a high starting point to quickly enter the market, in September 2000, Galanz entered the air-conditioning potato loss refrigeration industry with 2 billion yuan. In the first freezing year (FY2001), production and sales reached 500,000 units.
In 2002, it is expected to produce and sell 1.8 million units, including 600,000 units in China and 1.2 million units in export. In July 2007, Galanz entered the first air conditioner, established Galanz air conditioner, sales exceeded 100 million in 2010, and the growth rate of Galanz air conditioning series is obvious to all: V8, K8, Calm Treasure, Xinju Bao, Q Ya, Smart Treasure, Zun Ruifeng, Mengjing Wind, Zunmeng Feng, Xiaokang Bao, Chunfeng Bao, Cestbon, Zhipai Shuyun, Yixuan.
Midea air conditioning. <>-related expansion: Galanz air conditioning is positioned as "the world's largest air-conditioning specialized manufacturing center", with a high starting point to quickly enter the market, in September 2000, Galanz entered the air-conditioning potato loss refrigeration industry with 2 billion yuan. In the first freezing year (FY2001), production and sales reached 500,000 units.
In 2002, it is expected to produce and sell 1.8 million units, including 600,000 units in China and 1.2 million units in export. In July 2007, Galanz entered the first air conditioner, established Galanz air conditioner, sales exceeded 100 million in 2010, and the growth rate of Galanz air conditioning series is obvious to all: V8, K8, Calm Treasure, Xinju Bao, Q Ya, Smart Treasure, Zun Ruifeng, Mengjing Wind, Zunmeng Feng, Xiaokang Bao, Chunfeng Bao, Cestbon, Zhipai Shuyun, Yixuan.
Midea air conditioning. I don't have any problems with the remote control.
I didn't understand what you said, kiss.
The start-up is normal, the temperature is set freely, and the external machine is stopped and the internal machine is normal for three minutes.
The remote control operation is no problem.
Is the indoor temperature at the temperature you set?
It's like this every time you turn it on.
Set 19 degrees.
Kiss, you can call the product customer service ** to find someone to repair it.
I can think of a way to deal with it.
Kiss your air conditioner if it is broken, you can only find a professional to repair it.
-
Hello dear <>
There may be many reasons for the problem that Galanz air conditioner outdoor unit stops after 3 minutes of work, and the following are some possible reasons and solutions:1Outdoor unit failure:
There may be faults in the outdoor unit itself, such as damaged circuit boards, motor failures, compressor failures, etc., causing the outdoor unit to shut down after working for a period of time. The solution is to contact a professional air conditioner maintenance personnel for overhaul and repair. 2.
Air conditioner power supply problem: The air conditioner power supply is unstable, or the power supply line is not in good contact, aging and other problems such as anti-fiber, which may cause the outdoor unit to shut down after working for a period of time. The solution is to check whether the air conditioner power supply and the wires are in good contact, and replace the aging wires in time.
3.Insufficient cooling capacity of the air conditioner: If the cooling capacity of the air conditioner is insufficient, the side-shooting can cause the outdoor unit to shut down after working for a period of time.
The solution is to check whether the air conditioning and refrigeration system is normal, if not, you need to contact professional air conditioning maintenance personnel for maintenance and maintenance. 4.Air conditioner indoor unit filter and condenser clogged:
If the air conditioner's indoor unit filter and condenser are clogged and the air circulation is poor, it may cause the outdoor unit to shut down after working for a period of time. The solution is to regularly clean and replace the air conditioner's indoor unit filter and condenser. In short, if your Galanz air conditioner outdoor unit stops after 3 minutes of work, it is recommended that you contact professional air conditioner maintenance personnel for maintenance and maintenance to determine the specific cause of the problem and take corresponding measures to solve it.
Air conditioning is divided into indoor unit and outdoor unit, air conditioning failure people often only consider whether the indoor unit is faulty, and the reason why the air conditioner is not refrigerated is that the air conditioner outdoor unit does not work, how to deal with the air conditioner outdoor unit does not work? >>>More
1. In most cases, the air conditioning system stops working intermittently due to poor heat dissipation. Clean and inspect the heat sink. >>>More
If the air conditioner won't power on (turn on), follow the steps below to solve it: >>>More
Compressor starting capacitance, whether the capacity is appropriate, whether the wiring is loose, or fails. >>>More
Automatic protection when the voltage is too low. Detection method: The speed of the compressor, the pressure detection value of the high-pressure sensor and the low-pressure sensor are detected by the control p-plate, and the theoretical current value of the compressor calculated according to the detected parameters is compared with the actual current value detected by the power transistor. >>>More