There will be a lot of electronic equipment in the monitoring room, and the use of anti-static flooring can effectively reduce the damage of static electricity to electronic equipment.
There must be a lot of electronic equipment (computers, monitoring supporting electronic equipment, communication equipment, etc.), optical fibers, network cables, etc., in the monitoring room, which must prevent electronic interference. Static electricity can also interfere with these electronic devices.
-
Lay anti-static flooring for the community monitoring room.
One is to prevent the interference of static electricity, and the other is to make reasonable wiring.
-
This is standard, because the place concentrates a lot of things, prevents interference, requires anti-static flooring. The second is to facilitate good wiring under the floor. Good maintenance, good increase.
-
This is because of the monitoring in the community, he is arranged underneath, and now it is installed, if there is a little water or leakage in the society underneath, it may lead to electricity leakage.
-
According to the substrate, anti-static flooring can be divided into: wood-based (particleboard), inorganic (calcium sulfate anti-static flooring), steel (all-steel anti-static flooring), aluminum (aluminum alloy anti-static flooring), resin, and others.
Anti-static flooring is divided into ultra-light (CQ), light (Q), ordinary (P), standard (B), heavy (Z), and super heavy (CZ) according to the load-bearing.
Common anti-static flooring:
All-steel anti-static flooring is divided into: all-steel PVC anti-static flooring, all-steel HPL anti-static flooring, all-steel ceramic anti-static flooring, and all-steel permanent PVC anti-static flooring.
Calcium sulfate anti-static flooring is divided into: calcium sulfate PVC anti-static flooring, calcium sulfate HPL anti-static flooring, calcium sulfate ceramic anti-static flooring.
Aluminum alloy anti-static flooring is divided into: aluminum alloy PVC anti-static flooring, aluminum alloy HPL anti-static flooring, and aluminum alloy ceramic anti-static flooring.
The network floor is divided into: OA network floor, GRC network floor, six-bread steel network floor, and four-bread steel network floor.
-
Generally speaking, it is recommended to use, and there are many functions of anti-static flooring, especially in the monitoring room, computer room, computer room, clean room and other floors, the functions are particularly obvious.
1. The use of anti-static flooring can effectively dissipate static electricity, so that people and equipment can play a more efficient role.
2. Lay an anti-static floor, and there is space under the floor, which can be used to wiring and make bridges, so that the cables do not need to be exposed. Compared with the original straight floor, the cables are exposed everywhere, which is unsightly and unsafe.
3. The anti-static floor is not high, the performance is stable, and it is an indispensable helper for the computer room!
Zhuhai Shenfei anti-static floor provides information.
-
Answer: Yes, the weak motor room and the control room must be laid with anti-static flooring in accordance with the specifications, which must be accepted according to the specifications, and after the installation of the raised floor, the baseboards (wood, stone) are installed along the room around the room according to the design requirements. The installation of the baseboard should be firm and straight, and the horizontal error should not be greater than 3mm within the range of 5m.
Testing and quality inspection 1. Instruments used in the ground testing of the raised floor: Digital megohmmeter: the test voltage is 100V, and the range should be greater than ohms; The accuracy level must not be lower than the grade.
Electrodes: two, copper, the surface should be chrome-plated, cylindrical, and used with a digital megohmmeter to test the surface resistance and system resistance of the anti-static ground Measuring electrode gasket: dry conductive sponge or conductive rubber, the volume resistance should not be greater than ohms.
Ground Resistance Measuring Instrument: It is used to measure the ground resistance between the ground electrode and the earth. The measuring range and accuracy class must meet the measurement requirements.
Ruler: The length should be 2m, which is used to check the flatness of the ground. The instruments used in the anti-static performance test should be within the validity period of measurement and identification.
2. The test environment temperature should be between 15-30, and the relative humidity should be less than 70%. 3. One end of the test electrode is placed on the floor surface. The other test electrode is connected to the ground terminal.
4. The quality assessment method shall be implemented in accordance with the provisions of GB2828 (batch by batch inspection, counting and sampling procedures and sampling tables). 5. The electrical performance indicators of the anti-static raised floor surface shall comply with the following provisions: System resistance:
The electrostatic conductive type is less than 106 ohms, and the electrostatic dissipative type is ohms. Surface resistance: ohms (measuring electrode spacing 900--1000mm) The system ground resistance should meet the design requirements.
6. The covering layer of the anti-static raised floor should be soft and smooth, uniform in color, should not blister, and should not have obvious defects; The layout should be pasted firmly, and there should be no glue opening.
-
Electrostatic flooring is a kind of flooring that can prevent static electricity, also known as dissipative static flooring. When it is connected to the ground or to any lower potential, it dissipates the charge they have and avoids static electricity. Because of this performance, electrostatic flooring has been widely used in the machine rooms of various plants.
Resistance is characterized by a resistance between the 5th power and the 9th power of 10.
The computer room generally uses all-steel anti-static flooring, if the requirements are higher, you can choose calcium sulfate anti-static flooring, the material of both is different, and the load-bearing is also different, of course, the calcium sulfate will be slightly higher than that of all-steel. But to decide according to the actual situation, if you want to go further to get the best solution and the latest anti-static flooring** can learn more.
-
The concept of anti-static flooring: Anti-static flooring, also known as dissipative static flooring, is a kind of flooring that is high-grip when it is grounded or connected to any lower potential point, so that the charge can be dissipated, characterized by a resistance between 10 to the 5th power to 10 ohms to the 9th power. Section 20 of the GB50174-2008 Code for the Design of Electronic Information System Computer Room stipulates:
The surface resistance or volume resistance of the anti-static floor or floor should be:
The working principle of anti-static flooring: anti-static flooring can introduce the static electricity generated in the room into the ground through the metal overhead layer through the surface floor, this kind of floor has the ability to conduct electricity, because it contains conductive fibers inside, and copper foil needs to be laid under the floor during construction, so that it can be conducted into the ground when static electricity appears on the floor, so that the floor will not be accompanied by electrostatic ions. The anti-static floor not only has the function of anti-static, but also has the characteristics of fire retardant, wear resistance, long life, and beautiful appearance.
The function of anti-static flooring: it is conducive to the repair and maintenance of the bottom of the equipment; It eliminates the harm of cable exposure to the human body; It can make the electrostatic charge leak to the ground and reflect electromagnetic radiation; It can protect all kinds of cables, wires, data cables and sockets from damage.
-
The electrostatic floor is generally used in the power distribution room, the weak current room and the fire control room.
-
First of all, I will give you a lesson on the dangers of "static electricity".
The anti-static technology of the computer room is part of the safety and protection of the computer room. Static electricity due to various reasons is one of the most frequent and difficult hazards to eliminate. Static electricity will not only cause random failures, malfunctions or calculation errors when the computer is running, but also may cause the breakdown and destruction of certain components, such as CMOS, MOS circuits, two-stage circuits, etc.
In addition, static electricity has a noticeable effect on the external devices of the computer. Display devices with cathode ray tubes, when subjected to electrostatic interference, will cause image disorder and blurry. Static electricity can also cause malfunctions such as abnormal work such as modem, network card, fax, etc., and abnormal printing of the printer.
Problems caused by static electricity are not only difficult for hardware personnel to detect, but sometimes software personnel can mistakenly believe that it is a software failure, resulting in work chaos. In addition, when static electricity passes through the body and discharges electricity to a computer or other device (so-called ignition), it can also give the impression of electric shock when the energy reaches a certain level (such as sometimes touching a computer monitor or chassis).
Therefore, the anti-static floor is to introduce static electricity to the ground through grounding to protect your equipment.
-
Power distribution room, monitoring room, data center, communication room, computer room, laboratory, etc. generally need to install anti-static flooring.
-
Lipin anti-static floor is made of high-quality alloy cold-rolled steel plate of Shanghai Baosteel Group, which is spot welded after stretching. The exterior is sprayed after phosphating, the inner cavity is filled with foamed cement, and the upper surface is pasted with high wear-resistant anti-static hydroramide (HPL) or PC veneer, and the conductive edge strip is inlaid around it. Anti-static flooring is widely used in computer rooms, satellite ground station rooms, electrosynthetic control rooms, TV transmitter control rooms, microwave communication station rooms, program-controlled exchange rooms, clean workshops, electronic instrument factory assembly workshops, confidential optical instrument manufacturing rooms, hospitals, schools and other occasions with anti-static requirements.
Features of anti-static flooring:
1. Steel composition, high mechanical strength, strong bearing capacity, good impact resistance 2, surface electrostatic spraying, soft light, wear resistance, waterproof, fire prevention, anti-health, 3, pasted decorative high-pressure laminate, excellent wear resistance and anti-static performance, anti-pollution, easy to clean, strong decoration.
4. High precision, good interchangeability, flexible assembly, convenient maintenance, long service life 5. There is no electrostatic conductive rubber strip around the floor, which is a straight edge or folded edge, and the overall smoothness after paving is beautiful and generous. It makes people have a sense of integration, and makes the room appear simple, beautiful and generous.
-
Anti-static collision flooring may not be common in daily life, mainly used in computer room, microwave communication station room, program control room, radio control room, TV transmitter control room, integrated circuit production clean workshop, electronic instrument manufacturing workshop, hospital hand-to-life operation room, anesthesia room and other pipeline laying is more concentrated and dust-proof, anti-static place, large-scale, super-human scale integrated circuit clean workshop, computer, communication and electronic equipment manufacturing industry: used in traffic command system, Electronic equipment production workshop ground, program-controlled switch room, mobile communication room, radio and television transmission center, transportation dispatching center, control electrostatic discharge to computer communication, all kinds of electronic equipment and electrostatic sensitive devices, to prevent damage to computer memory and electronic instruments. It is used for munitions sensitive to static electricity, flammable and explosive places, petrochemical workshops and hospital operating rooms, anesthesia rooms, oxygen bars, etc.
-
1. It is forbidden to squeeze hard objects and sharp objects, impact, scratch the finish and plastic coating layer, try to replace the soft sole when entering the venue, and avoid high heels and hard-soled shoes from entering the site to prevent damage to the antistatic performance and aesthetics of the decorative surface; Avoid direct sunlight to avoid premature discoloration and aging of the finishing layer. 2. Do not use a suction device to suck the floor to move, it may fall off on the way; There may be a sound when walking after the floor is laid, which is related to the installation of the floor, not the performance of the floor itself. 3. When carrying items on the raised floor, it is forbidden to directly push the object on the board surface, resulting in direct friction between the object and the ground, resulting in scratches on the board surface.
4. When using and maintaining the equipment in the lower space of the floor, the floor suction device should be used for floor installation, and the floor should be handled gently to avoid damage to the floor. 5. It is forbidden to rinse with water during use, you can use a clean mop and rag to keep the board surface clean, and be careful not to spill a large amount of detergent liquid on the floor, so as not to flow under the floor and affect the normal operation of the lower line and equipment. 6. The anti-static spray layer of the raised floor should be prevented from scratching during use, and if scratches are found, gray paint should be used to repair the coating to ensure the integrity of the coating.
In order to ensure the longevity of the service life of the floor in their homes, it is recommended that consumers should choose some more professional flooring companies for the purchase of indoor flooring, because they can provide professional installation.
Anti-static clothing is widely used, such as electronics, printing, film, electronic maintenance, petroleum, chemical, dust, etc. >>>More
The question of whether it is good or not, and who is better, is a matter of opinion. Generally, the organization's qualifications, industry experience, external resources, and successful cases should be comprehensively evaluated and considered. It needs to be measured from the aspects that you are currently concerned about, and it cannot be said in one sentence or two. >>>More
Grid design system (also known as grid design system, standard size system, program layout design, Swiss graphic design style, internationalist graphic design style) is a method and style of graphic design. The use of fixed lattice design layout, its neat and simple style, was very popular after World War II, and has become one of the mainstream styles of the design of today's Epitomy publications. >>>More
The main reasons for using tris-saturated phenol instead of directly using phenol are as follows: >>>More
1) Use a purple clay pot to make tea, the tea aroma is rich and long-lasting. The purple clay spout is small and the lid is tight, and the inner wall of the pot is rough, which can effectively prevent the aroma from being lost prematurely. The long-used purple sand teapot is hung with a layer of brown-red tea rust on the inner wall, and the longer the use time, the more tea rust accumulates on the inner wall, so the tea soup is more mellow and fragrant after brewing tea. >>>More