-
Industrial aluminum profile clean shed is also called aluminum profile clean shed, aluminum profile clean room, purification shed. It is a relatively closed small space made of industrial aluminum profile as the main shed frame, with plexiglass or acrylic sheet. This kind of industrial aluminum profile clean shed is generally used in factory workshops or clean rooms with high requirements for production environmental hygiene.
Generally, it is composed of a mechanical air supply unit, and its internal cleanliness is higher than that of a clean room.
1. Assembled structure design, easy installation and short delivery cycle.
2. Easy to move (universal wheels can be selected).
3. Modular structure, easy to improve the purification level, strong scalability, and high reuse value.
4. Compared with the ultra-clean workbench, the purification shed has the advantages of low cost, fast construction and low floor height requirements compared with the traditional clean room.
5. The whole is made of cold-rolled steel plate spraying, using all stainless steel and aluminum alloy and other materials, which is light in weight, corrosion-resistant, rust-proof, beautiful and generous.
6. Adopt adjustable air volume system to ensure that the wind speed in the working area is in an ideal state.
7. Applicable to ultra-clean production line, easy to use by multiple people.
Because the aluminum profile clean shed is made of multi-specification industrial aluminum profiles, it has large optional shape, light and easy to handle, fast construction, low cost, environmental protection and utilization. Due to the use of modular aluminum accessories connection, it is easy to disassemble and assemble, firmly connected, not easy to loosen, and simple to maintain in the later stage. And it is generally made of transparent plexiglass and acrylic sheets.
You can clearly see the operation of the internal equipment, which can be silent and dust-proof, and avoid production personnel from entering the working area of the equipment by mistake and causing injury.
-
Modular design: assembled structure, no need for welding, easy to improve the cleanliness level. It is highly scalable, reusable, and easy to assemble and disassemble.
2.Selected materials: anti-static PVC mesh curtain, adjustable hoof angle, movable universal wheels, easy installation and maintenance.
3.Simplicity structure: Compared with the dust-free operation table, the available effective space inside is large, and it can be used with the assembly line conveyor line.
4.Strong repeatability: the module frame can be reused, the cost is low, the construction is fast, and the floor height requirements are low.
-
1.The purification level of the external workshop of the electronic plant and other workshops is low, and the internal needs of a higher level of required areas, such as the assembly line operation area, the inspection countertop, and the special equipment work to release dust particles or special odors, which is suitable for the construction of local small area areas, and the core process is controlled in the clean area to improve the product yield, especially the production equipment of some optoelectronic industries, the production process will release peculiar smells, and the self-contained fan filtration system on the top of the Ecolead aluminum profile clean shed can improve the internal air quality. Provide employees with a comfortable air environment.
2.Laboratory, the outside of the single flushing ridge is an ordinary office, a plant area, and the individual experimental research content needs to have a certain temperature and humidity, illumination, cleanliness requirements, and the experimental work of specimens, bacteria, drug components, etc. is controlled in the area of the clean shed of purified aluminum profiles, so as to improve the success rate of scientific research projects.
3.In the field of medicine and food, in the production and packaging process, it is generally recommended to use Nanjing Meicheng Aluminum's 100-grade aluminum profile clean shed, the higher the level, the higher the product, the product can meet the national drug GMP and food QS standards in terms of safety and hygiene, and can also meet the trust of consumers. In recent years, in the sales of aluminum profile clean shed, more and more catering industry is gradually paying attention to the control of food safety and hygiene, aluminum profile clean shed, air shower room and other equipment are widely used in fast food, cooked food, frozen food, bread baking and other enterprises.
-
Compared with the traditional clean room, the industrial aluminum profile clean shed is easy to assemble and install, and there are special aluminum profile accessories, which can greatly shorten the production cycle. The modular structure of the cleanroom can not only improve the purification level, but also reuse and extend. The ultra-purified aluminum profile workbench can be placed inside, and the internal space is effectively utilized.
If it is a small clean shed, the silent universal caster is installed at the bottom, which is easy to move and can be replaced at any time, which can greatly reduce the cost and produce quickly.
-
Generally, it is aluminum, fans, anti-static curtains, door curtains and some accessories, in order to look good, you can make PVC boards, but also need to look at the requirements for cleanliness, and the requirements are relatively high and you need to use blinds.
-
Everyone should know that in general, when selecting materials, the load-bearing strength of aluminum profiles should be considered, and then the use of materials should be carried out. In the clean room or clean room, 40 series aluminum profiles are generally used, but there are also a small number of customers who may use 3030 aluminum profiles or 5050 aluminum profiles, 6060 aluminum profiles to make. These are all types of reference that need to be selected according to the opinions given by technical personnel.
-
Clean booth is the fastest and most convenient to establish a simple clean room draft chain, clean shed has a variety of cleanliness levels and space collocation, can be designed and produced according to the needs of use, so its simple use, flexibility, easy installation, short construction period and removability as its main features, clean shed can also be for the general level of clean room in the local area needs high cleanliness of the place to do local additions to reduce costs. Clean shed is an air purification equipment that can provide a local high clean environment. The clean shed is mainly composed of a box, a fan, a primary air filter, a damping layer, a lamp, etc., and the shell is sprayed.
The product can be hung and ground supported, with compact structure and easy to use. It can be used individually or connected in multiple ways to form a ribbon-like clean area.
The clean shed is made of industrial aluminum (or stainless steel Fangtong and Tiefangtong spraying) as the frame, the fan filter unit (FFU) supplies air, and the anti-static vertical curtain (or tempered glass) is hung around it, and its internal purification level can reach 100-10000 levels. It is suitable for areas with high local purification level requirements in the operation area. The cleanliness of a clean shed is often affected by the air flow, in other words, the movement and diffusion of dust generated by people, machine compartments, building structures, etc. are controlled by the air flow.
The clean room uses HEPA and ULPA to filter the air, and the dust collection rate is high, so the air filtered by this filter can be said to be very clean.
However, in addition to people, there are also dust sources such as machines in the clean room, and once the dust generated by these dust spreads, it is impossible to maintain a clean space, so it is necessary to use air flow to quickly expel the dust generated outside. The airflow in the clean shed is an important factor in the performance of the clean room, the airflow speed of the general clean room is selected, the airflow speed is a breeze area, easy to be disturbed by the actions of people, machines, etc., and tends to be chaotic, although the increase in wind speed can inhibit the impact of this disturbance and maintain cleanliness, but due to the increase of wind speed, it will affect the increase in operating costs, so it should meet the required cleanliness level, in order to achieve the most appropriate wind speed, in order to achieve the appropriate wind speed to achieve economic results.
-
The clean room is composed of two main structures: the frame part and the baffle part. The baffle part is generally aluminum alloy plate, plexiglass plate, PVC board, aluminum-plastic board, etc., and anti-static door curtains, flame retardant boards, etc. will be used when there are wide holes. The aluminum profile frame is processed and assembled by industrial aluminum profiles, and the profiles used are generally 4040 and 4080 aluminum profiles.
However, there are also large-scale clean rooms, and the cross-section requirements for aluminum profiles are relatively large. There are 5050 and 100100 etc. What kind of industrial aluminum profile is selected according to the bearing capacity of the whole structure of the clean room, if the large clean room needs a large cross-sectional profile, if it is a small general 4040 aluminum profile can meet the requirements.
-
The airflow diversion point on the surface of the general operating table or production equipment should be located at the place where the clean room space is spaced at the distance between the partition board 2 3, so that when the operator is working, the airflow can flow from the front imitation part of the process area to the operation area, and the fine dust will be taken away; If the shunt point is placed in front of the process area, it will become an improper airflow divert, and most of the airflow will flow to the process area, and the dust caused by the operator's operation will be carried to the back of the equipment, and the workbench will be contaminated, and the yield will inevitably be reduced. Obstacles such as the work table in the clean room will have eddy current phenomenon at the junction, and the cleanliness near it will be relatively poor. The selection of assembly materials and the perfection of equipment layout are also important factors in whether the airflow becomes a vortex phenomenon. The fan sucks the air from the top of the FFU, filters it through the primary filter, the high-efficiency filter, and the filtered clean spring air is sent out to the clean shed with uniform wind speed and speed resistance on the entire air outlet surface.
A homotrographic layer is formed, which makes the clean air flow in a vertical unidirectional flow, thus ensuring the required cleanliness in the working area.
-
The maintenance of uniform airflow is also an important factor, if the uniform airflow cannot be maintained, it means that the wind speed of Liangjujube is different, especially on the wall, the airflow will be vortex along the wall, and it is actually very difficult to achieve high cleanliness. In order to maintain a uniform airflow in the direction of vertical laminar flow rubber dismantling, it is necessary to: (a) there must be no difference in the speed of the wind rushing on the blowing surface; (b) There shall be no difference in the speed of the suction surface of the floor return air panel.
The speed is too low or too high (, there are vortex phenomena, and the speed, the airflow is more uniform, the general clean room, the wind speed is taken between. There are many influencing factors that affect the airflow of the clean shed, such as process equipment, personnel, clean room assembly materials, lighting equipment, etc., and the diversion point of the airflow above the production equipment should also be considered.
-
Frame: Industrial aluminum (or stainless steel Fangtong, iron Fangtong spraying) as the frame is stable, beautiful, no rust, no dust; Anti-static hanging curtain: anti-static vertical curtain (or acrylic plate) is used around it, which has good anti-static effect, high transparency, clear grid, good flexibility, no deformation, and is not easy to age.
Fan filter unit FFU: Singapore PCI centrifugal fan, with long life, low noise, maintenance-free, small vibration, stepless speed change, etc., the fan quality is reliable, long working life, coupled with the unique air duct design, greatly improve the efficiency of the fan, reduce the noise! The internal purification level can reach 100-100k; It is especially suitable for areas with high local purification level requirements in the workshop, such as assembly line operation areas.
The interior adopts a special purification lamp for the clean room, which does not produce dust.
-
The airflow in the clean shed is an important factor in the performance of the clean room, the general airflow speed of the clean room is selected, the airflow speed is a breeze area, easy to be disturbed by the actions of people, machines, etc., and tends to be chaotic, although increasing the wind speed can inhibit the impact of this disturbance and maintain cleanliness, but due to the increase of wind speed, it will affect the increase of operating costs, so when meeting the required cleanliness level, the most appropriate wind speed can be used to achieve the appropriate wind speed to achieve the economic effect. On the other hand, in order to achieve the stable effect of cleanliness in the clean room, the maintenance of uniform airflow is also an important factor, if the uniform airflow cannot be maintained, it means that the wind speed is different, especially on the wall, the airflow will extend the wall surface to occur vortex code flow, at this time it is actually very difficult to achieve high cleanliness.
-
There are many factors that affect the airflow of the clean shed, such as process equipment, personnel, clean room assembly materials, lighting equipment, etc., and the diversion point of the airflow above the production equipment should also be considered. The airflow diversion point on the surface of the general operating table or production equipment should be located at the place where the distance between the clean room space and the partition board is 2 3, so that when the operator is working, the airflow can flow from the inside of the process area to the operation area, and the fine dust is taken away; If the shunt point is configured in front of the process area, it will become an improper airflow diversion, at this time, most of the airflow will flow to the process area, and the dust caused by the operator's operation will be carried to the back of the equipment, and the workbench will be polluted by dust and liquid, and the yield will be reduced.
-
The airflow in the clean shed is an important factor in the performance of the clean room, the general airflow speed of the clean room is selected, the airflow speed belongs to the breeze area, which is susceptible to the action of people, machines, etc. and interferes with the chaos, although the increase in wind speed can inhibit the impact of this disturbance and maintain cleanliness, but due to the increase in wind speed, it will affect the increase in operating costs, so it should meet the required cleanliness level, in order to achieve the most appropriate wind speed, in order to achieve the appropriate wind speed to achieve economic results.
On the other hand, in order to achieve the stable effect of cleanliness in the clean room, the maintenance of uniform airflow is also an important factor, if the uniform airflow cannot be maintained, it means that the wind speed is different, especially on the wall, the airflow will run along the wall surface to vortex, and it is actually very difficult to achieve high cleanliness.
In order to maintain a uniform airflow in the direction of the vertical laminar flow, it is necessary to: (a) there must be no difference in the speed of the wind speed at the blowing surface; (b) There shall be no difference in the speed of the suction surface of the floor return air panel. The speed is too low or too high (, refers to the occurrence of vortex in tan, and the failure of the speed, the airflow is more uniform, the general clean room, the wind speed is taken between.
Broken bridge aluminum is heat-insulated broken bridge aluminum. Thermal insulation bridge aluminum is a non-metallic low thermal conductivity separator sandwiched in the middle of the aluminum profile, which can obtain excellent thermal insulation performance of the aluminum profile, this is because the heat conduction is blocked when the heat is conducted to the non-metallic isolator through the aluminum alloy with excellent thermal conductivity, and the heat can not be transferred to the inner wall, such aluminum is called broken bridge aluminum. A broken bridge means that heat energy can be transferred indoors and outdoors. >>>More