Why doesn t the leakage protection indicator light of the electric water heater light turn on?

Updated on home 2024-03-27
12 answers
  1. Anonymous users2024-02-07

    1. The power pole base has no electricity or poor contact: check whether there is electricity with a pen and whether the contact between the leakage protection plug and the socket is good;

    2. There is no water in the water heater (or it is not filled), the electric heating pipe is in a dry burning state, the reset button of the leakage protection plug jumps up, cut off the power supply: first fill the water heater with water according to the instructions for use, and then press the reset button of the leakage protection plug, even if it can be restored to normal;

    3. The water temperature of the water heater is too high, and the reset button of the leakage protection plug jumps to cut off the power supply: the thermostat fails, replace the thermostat;

    4. If the water heater is leaking, the reset button of the leakage protection plug jumps up and cuts off the power supply: check whether there is leakage with a pen, and find out the leakage part with a pen for leakage, and try to eliminate the leakage. The above is the reason why the leakage protection indicator light of the electric water heater is not lit, find the problem in time to find professional personnel for maintenance, non-professionals do not check and disassemble by themselves!

  2. Anonymous users2024-02-06

    Possible reasons are:

    Wrong wiring connection: electric water heater.

    The plug and leakage protection switch.

    The zero wire and the live wire of the socket are plugged in backwards.

    The water heater enters self-protection: if the sprinkler head or hot water outlet valve is turned off directly after using the hot water, and when you turn off the hot water immediately and the water heater stops heating and heats up.

    There is still a large amount of waste heat released in the body, which causes the water temperature inside the heating body or inner tank to rise sharply, and the over-temperature protection is installed on the heating body or inner tank, so it is immediately sensed, so as to enter the protection state.

    It may also be caused by poor contact with the socket and excessive abnormal temperature rise.

    Use maintenance. 1. When putting on the water, the water outlet must be opened, and the air in the inner tank can be checked to see if the water is full;

    2. The power supply must be cut off before emptying;

    3. When it is installed in a closed manner, the water inlet valve must be open during heating;

    4. When you first open the valve, don't put the direction of the water towards the human body.

    If the electric water heater is used for a long time, if the user does not clean the inner tank of the hot branch Chihong water heater in time, it will cause serious scaling of the heating pipe, the heat of the electric heating pipe is not fully heated, and the hot water will heat up very slowly, which affects the normal use, and there is an accident of rupture due to uneven local heating, so the electric water heater should be maintained once a year.

  3. Anonymous users2024-02-05

    1. Reason: The power pole base has no electricity or poor contact. Solution: Use an electric pen.

    Check whether there is electricity and whether the leakage protection plug is in good contact with the socket.

    2. Reason: The water heater has no water (or is not filled), the electric heating pipe is in a dry burning state, and the reset button of the leakage protection plug jumps up to cut off the power supply.

    Solution: Fill the water heater with water according to the instructions for use, and then press the reset button of the leakage protection plug, even if it can return to normal.

    3. Reason: The water temperature of the water heater is too high, and the reset button of the leakage protection plug jumps up, cutting off the power supply.

    Treatment: Thermostat.

    malfunction, replace the thermostat.

    4. Reason: The electric heating pipe of the water heater is bad, which makes the reset button of the leakage protection plug jump up and cut off the power supply.

    Solution: If the electric heating pipe is damaged, replace the electric heating pipe.

    5. Reason: The water heater leaks, and the reset button of the leakage protection plug jumps up to cut off the power supply.

    Solution: Check whether there is leakage with a pen, such as using a pen to find out the leakage part, and try to eliminate the leakage.

  4. Anonymous users2024-02-04

    1. The power pole base has no electricity or poor contact residue: check whether there is electricity with a pen and whether the contact between the leakage protection plug and the socket is good;

    2. There is no water in the water heater (or it is not filled), the electric heating pipe is in a dry boiling state, and the reset button of the leakage protection plug jumps up to cut off the power supply: first fill the water heater with water according to the instructions for use, and then press the reset button of the leakage protection plug, even if the normal vertical letter slag can be restored;

    3. The water temperature of the water heater is too high, and the reset button of the leakage protection plug jumps to cut off the power supply: the thermostat loses Tanthyl, and the thermostat is replaced;

  5. Anonymous users2024-02-03

    Summary. According to your description, the outlet has electricity, the reason why the water heater is dead. The first one is that the water heater plug and connection line are faulty and the circuit is broken.

    Timely replacement will do. The second is the internal failure of the water heater. If the heating fuse is burned, or the heating rod is burned, it will cause no power and need to be returned to the factory for repair.

    The water heater leakage protection plug light is on, but the water heater has no electricity.

    According to your description, the outlet has electricity, the reason why the water heater is dead. The first one is that the water heater plug and connection line are faulty and the circuit is broken. Timely replacement will do.

    The second is the internal failure of the water heater. If the heating fuse is burned, or the heating rod is burned, it will cause no power and need to be returned to the factory for repair.

    How can you tell? What is certain is the problem of the water heater, which leads to electricity leakage, and the water heater has no electricity.

    But the leakage protector did not trip.

    This mainly depends on what kind of water heater you are using.

    Striker. 1. The isolation layer on the outside of the heating rod of the electric water heater is damaged. In this case, the current may enter the water from the heating rod, and then the water can conduct electricity within a certain range, so that when we use the water, we will find that there is a serious current in the water, and an electric shock accident may occur.

    This is also the main reason for the leakage of electric water heaters. 2. Other electrical components of the electric water heater leakage.

    3. The reason for the circuit used in the electric water heater. Because our electric water heaters use external power sockets, and if the sockets are not installed correctly and there is a problem with the insulation layer, there may be leakage. In this case, these leakage currents will also be transmitted outward, and eventually an electric shock accident will occur.

  6. Anonymous users2024-02-02

    Summary. The reason why the electric water heater does not respond when plugged in:

    1. The external wires are not connected, and the electricity does not come in;

    2. Quality problems or internal aging of electric water heaters;

    3. The quality of the air switch is not good, or it is not connected well;

    4. The wire is not connected, sometimes when the wire is connected, the wire is stuffed hard in order to be reliable, and then the tablet of the air switch is only pressed on the rubber of the wire, and the wire is not pressed to cause the machine to be not energized.

    The water heater leakage protection plug light is on, but the water heater has no electricity.

    The reasons why the electric water heater does not respond when plugged in: 1. The external wires are not connected properly, and the electricity does not come in; 2. Quality problems or internal aging of electric water heaters; 3. The quality of the air switch is not good, or the wheel is not connected well; 4. The wire is not connected well, sometimes when the wire is connected, in order to be reliable, the wire is stuffed hard, and then the pressure of the air switch is only pressed on the rubber of the wire, and the wire is not pressed to cause the machine to not be energized.

    1. The indicator light is on but the jujube is not heated, it may be a mistake in temperature adjustment, and the temperature can be adjusted to a suitable position; 2. If the indicator light is on but not heated, it may be that the heating tube is damaged, and it should be reported for repair, and the professional maintenance personnel will replace it; 3. If the indicator light is on but not heated, it may be that the line thermostat is damaged, and it should be reported for repair, and the line thermostat should be replaced by professional maintenance personnel;

  7. Anonymous users2024-02-01

    Analysis of the reasons and solutions for the insulating light of the electric water heater not to light up:

    If the power supply is not connected, just connect the power supply; In the state of heat preservation, the indicator light turns to the heating state for about 5 minutes, which is normal; The indicator light is broken, and there is a normal hot water use certificate indicating that the indication is bad and needs to be replaced.

    The over-temperature protector is disconnected, and the reset lever has bounced up, which proves that there is a problem with the internal parts, and the over-temperature protector can be reset only after the inspection and maintenance are qualified.

    The heating pipe of the water heater is broken, and the resistance measured by a multimeter is infinity (normal is tens of ohms), which proves that it is broken and needs to be replaced; The thermostat is broken, and the resistance measured by a multimeter is infinity (normal is 0 ohms) or rotates without a switch sound, which proves that it is broken and needs to be replaced; The controller is bad, there is a power input but no output to the heating pipe, and the controller needs to be replaced; The internal terminal blocks are burned out and the connecting wires need to be replaced.

  8. Anonymous users2024-01-31

    If the electric water heater is heating, the insulated light will not light up unless the water temperature has reached our set temperature, and then the insulated lamp will be lit. The heat lamp will go out.

    These are the two states of electric water heater working and heat preservation, and two lights cannot be lit at the same time.

  9. Anonymous users2024-01-30

    Under normal circumstances, the insulation light of the electric water heater is normally bright if it reaches a certain temperature, if the insulation lamp is not on, check the temperature sensor, whether it is faulty, and whether the temperature detection circuit board is abnormal, or if the insulation indicator is bad.

  10. Anonymous users2024-01-29

    The reason why the water heater insulation lamp does not light up is basically caused by the damage of the insulation bulb (there are also a few caused by poor contact of the temperature control switch), if the water heater can provide hot water normally, this problem can not be dealt with.

  11. Anonymous users2024-01-28

    Bad water heater, leakage protector, red light indicates alarm effect, the line has the consequence of damage, the normal situation is the green indicator light, so there is a consequence of leakage in the circuit, and it needs to be replaced and repaired in time.

    The water heater leakage protection switch is red light, which may be the following problem:

    1. The reason why the red light keeps flashing when using the water heater may be that there is an error in the connection of the hot water silver merger line in Sobozhou, and the zero line of the socket and the live wire are plugged in backwards.

    2. The pipe connection port is not connected.

    3. After the water heater is heated, there will be a large amount of waste heat in the inner tank, causing the internal air pressure to rise sharply.

    4. The red light keeps flashing due to the high temperature rise caused by poor contact of the socket.

  12. Anonymous users2024-01-27

    Summary. Hello dear, I'm glad to answer for you: What is the reason why the red light of the plugged water heater is not on and the green light is on?

    1.Check the leakage protection switch of the water heater, press the red button to see if the heating lamp is on, whether the contact is poor, these two have been checked and it is not bright, just change a leakage protection switch.

    2.The hot water pipe does not produce hot water, as long as the mixing valve of the hot water vapor is removed and cleaned.

    After the electric water heater is plugged in, the indication does not light up, and the reasons why it does not heat up are as follows:

    1.External Faults:

    1) Check whether the electric water heater socket at home has a 220V voltage.

    What is the reason why the water heater plug leakage protector turns on the green light and the red light does not light up.

    Hello, I am helping you to inquire about the relevant information and will reply to you immediately.

    The light on the water heater is on and will also heat.

    Normal is to heat the red light and stop the green light.

    Wait a minute, it will take time to reply one by one, please be patient, don't worry!

    Hello dear, I'm glad to answer for you: What is the reason why the red light of the plugged water heater is not on and the green light is on? 1.

    Check the leakage protection switch of the water heater, press the red button to see if the heating lamp is bright and whether the contact is poor. 2.The hot water pipe does not produce hot water, as long as the mixing valve of the hot water vapor is removed and cleaned.

    After the electric water heater is plugged in, the indication is not lit and it is not heated, and the reason for this is as follows: 1External Faults:

    1) Check whether the electric water heater socket at home has a 220V voltage.

    I hope I can help you, I wish you a happy life and a smooth work!

Related questions
6 answers2024-03-27

Generally speaking, there is no danger in using an electric water heater normally, but if it is used incorrectly, there will still be certain dangers, so you should pay attention when using an electric water heater. >>>More

20 answers2024-03-27

According to the "Detailed Rules for the Safe Use of Household Appliances" issued in 2012, electric water heaters. >>>More

11 answers2024-03-27

1. The frequency of use determines the power outage >>>More

10 answers2024-03-27

In fact, it is equivalent to a mobile phone remote control. You need to connect with the water heater device through the ** software on the mobile phone, and connect the wifi network signal to the water heater through the mobile phone settings, and you can turn on and disable the power connection of the water heater through the mobile phone device. >>>More

11 answers2024-03-27

Rinnai is the aristocrat of the water heater, and if the age is not reached, he still has to give up easily. >>>More