Galanz air conditioner shows what to do with F9

Updated on home 2024-03-26
5 answers
  1. Anonymous users2024-02-07

    Galanz air conditioner F9 fault means that the outdoor temperature sensor is faulty, first see if the connection line of the sensor is broken, if not, use a multimeter to measure the resistance value, the resistance value is normal at about 5k, otherwise it should be replaced.

  2. Anonymous users2024-02-06

    Galanz air conditioner F9 failure indicates that the outdoor temperature sensor is faulty.

    Maintenance method: 1, see if the connection line of the sensor is broken, 2, use a multimeter to measure the resistance value, the resistance value is about 5k is normal.

  3. Anonymous users2024-02-05

    Burn the thermostat of the internal unit with a fire and it will start. What's going on?

  4. Anonymous users2024-02-04

    The air conditioner shows that F9 is faulty**: F9 refers to the protection of the PFC frequency board or the abnormal start of the outdoor fan. Scope of failure:

    1.The frequency conversion module of the outdoor unit is short-circuited. 2.

    The data of the outdoor unit is changed to the vertical finger frequency motherboard. 3.The temperature detection circuit of the outdoor unit is abnormal.

    4.High voltage protection of the outdoor unit. 5.

    The compressor is abnormal. Troubleshooting: first observe whether it can be started, check whether the power supply is good, whether the internal and external units are well ventilated, whether the pressure capacitance, whether the press is good or bad, whether the internal and external fans are rotating, whether the fan and fan capacitance are normal, and whether the AC contactor is working normally.

  5. Anonymous users2024-02-03

    Summary. Hello, F9 refers to PFC frequency board protection or outdoor fan start abnormality.

    Scope of failure: 1The frequency conversion module of the outdoor unit is short-circuited. 2.The data of the inverter motherboard of the outdoor unit is incorrect. 3.The temperature detection circuit of the outdoor unit is abnormal. 4.High voltage protection of the outdoor unit. 5.The compressor is abnormal.

    Troubleshooting: 1. Observe whether it can be started, check whether the power supply, the ventilation of the internal and external units is good, the capacitance of the press, the quality of the press, whether the internal and external fans are turned, whether the capacitance of the fan and the fan is normal, whether the AC contactor works normally, whether the system is poor or fluorine is excessive. 2. Check the sensor again, the main control board, the fault will not exceed the scope of the machine, if you are not a professional, clean the filter screen, turn on the machine after 30 minutes of power failure, if it does not operate normally after 30 minutes, the outdoor unit will be faulty.

    Galanz cabinet machine shows how to solve F9.

    Hello, F9 refers to PFC frequency board protection or outdoor fan start abnormality. Scope of failure: 1

    The frequency conversion module of the outdoor unit is short-circuited. 2.The data of the inverter motherboard of the outdoor unit is incorrect.

    3.The temperature detection circuit of the outdoor unit is abnormal. 4.

    High voltage protection of the outdoor unit. 5.The compressor is abnormal.

    Troubleshooting: 1. Observe whether it can be started first, check whether the power supply is good, whether the ventilation of the internal and external units is good, whether the capacitance of the rotten voltage retarder, whether the press is good or bad, whether the internal and external fans turn or not, whether the capacitance of the fan and the fan is normal, whether the AC contactor works normally, whether the system is poor or fluorine is excessive. 2. Check the sensor again, the main control board, the fault will not exceed the scope of the machine, if it is not a professional, clean the filter screen, turn on the machine after 30 minutes of power failure, and if the stool does not operate normally after 30 minutes, the outdoor unit will be faulty.

    You can double-check the above content.

Related questions
7 answers2024-03-26

The fault of F8 displayed on the common refrigerator** indicates that the system is abnormally protected; >>>More

15 answers2024-03-26

Indicates that the temperature bulb of the indoor unit of the air conditioner is faulty. Cause: It may be that the temperature sensor on the indoor unit condenser is malfunctioning. >>>More

13 answers2024-03-26

1. The blades of the motor fall off.

Solution: Repair the motor blades. >>>More

10 answers2024-03-26

Midea's air conditioner remote control board shows that HC stands for defrosting, and the steps to solve it are as follows: >>>More

11 answers2024-03-26

Generally, after turning on the heating function of the air conditioner, there will be a period of waiting time, during this time the air conditioner is heating, after this time, there will be hot air blowing out, the air conditioner will generally light up red, and the remote control will also display heating.