Battery problem: If you use a battery, you should first see if the battery is too old, and the water heater will not catch fire if the voltage is not enough.
Solenoid valve fault: If only the ignition sound is heard at the time of ignition, and there is no solenoid valve "click" magnetic absorption sound, it may be that the solenoid valve is damaged or aging, and the solenoid valve is aging, and it will be uncontrollableBefore confirming the quality of the solenoid valve, it is necessary to confirm whether the ignition control circuit can be normal, if there is a problem, the solenoid valve can not be controlled.
Ignition fault: If one of the pulse igniters and controller fails, the water heater will not start.
Ignition needle or induction needle problem: the ignition needle deviation can be changed or the ignition needle can be placed correctly;If the aging problem of the induction is solved, just polish the induction and put it away.
Water pressure problem: The water cannot flow normally due to the infarction of the filter screen at the water inlet, and it can be cleaned and cleared.
Water-air linkage installation fault: the tympanic membrane in the water-gas linkage valve is aging or damaged, and the micro switch cannot be promotedThe micro switch is broken.
The smoke pipe does not vent properly. There is an infarction in the smoke pipe, and the smoke pipe is too long and not properly installed. Please refer to the instructions for double-layer smoke pipe installation of balanced water heaters.
-
<> Sakura water heater light on the red light may be no gas, the battery is insufficient, or the water pressure is insufficient, the water pressure switch is faulty, if it is a point difference travel firearm induction needle rust or corrosion, it needs to be replaced immediately, if it is over-temperature protection, check the waterway switch first and then press the reset switch, it may also be caused by the ignition damage failure, then the ignition needs to be replaced immediately.
-
Summary. Hello, I'm Orange, I'm glad to serve you, your question has been received, I'm inquiring for you, I'll reply you within 5 minutes, please wait
Hello, I answer the stool is a canopy orange, I am happy to serve you, your question has been received, is inquiring for you, 5 minutes clear and travel bell to reply to you, please wait
Power problems, whether the battery is too old, replacing the battery with a new one can solve the problem.
If the solenoid valve is aging and broken, you can replace the solenoid valve.
If the gas pressure is too high or too low, adjust it to normal.
I hope mine is helpful to you, and if there is anything you don't understand, you can ask me
-
Summary. The moving ignition device is malfunctioning!
First of all, make sure that the ignition power is sufficient and well connected (if the machine uses a battery, replace the battery first)!
If it is not for the above old-fashioned water-gas linkage starting structure, it may be that the water current sensing starting device is faulty, and if it is not ignited, it is the controller failure, if the first two are not problematic, it is the failure of the micro switch or the controller itself. Check and rule out the above one by one. If the controller ignition, the micro switch is broken, and then observe whether the micro switch lever can be fully opened every time the machine is started (if the ignition cannot be opened, the diaphragm of the water-air linkage valve is aged or damaged, and the diaphragm can be replaced).
Hello, my Sakura gas water heater is also red light, can't hit **, no hot water, what's going on?
The moving ignition device is malfunctioning!First of all, it is necessary to ensure that the ignition power is sufficient, and the connection belt is good (if the machine uses the battery, replace the battery first)! If it is not for the above old-fashioned water-gas linkage starting structure, it may be that the water current sensing starting device is faulty, and if it is not ignited, it is the controller failure, if the first two are not problematic, it is the failure of the micro switch or the controller itself.
Check and rule out the above one by one. Short-circuit the output lead of the micro switch, if the controller is ignited, the micro switch is broken, and then observe whether the micro switch lever can be fully opened every time the machine is started (if the ignition cannot be turned on on the line return, the diaphragm of the water-air linkage valve is aged or damaged, and the diaphragm can be replaced).
Okay dear. Hurry no.
It is good in the morning, and it is hot in the afternoon.
-
1. In this case, it may be a problem with the power supply, the battery is too old or the battery is out of power. 2. It is possible that the electric igniter is malfunctioning. 3. It is also possible that the ignition magnetic needle or induction magnetic needle is aging or damaged.
4. In addition, when the water pressure is too low, the water heater cannot be started normally, and there will be a filter screen at the water inlet of the water heater.
Suggested workaround:
It is recommended to check whether it is caused by a power supply problem first, you can remove the old battery, replace it with a new one, and then try to ignite it.
Check whether the electric lighter is faulty, if the electric lighter has a search Huai fault, then you need to replace the electric lighter, after the replacement can solve the problem that the cherry blossom gas hot water can not ignite without prompt.
In addition, if the ignition magnetic needle is out of position or aging, you can replace the new ignition needle, and the ignition needle should be placed correctly, if it is the aging of the induction magnetic needle, you need to polish the induction magnetic needle and place it, as long as the flame can fully burn the magnetic needle, this problem can be solved.
Check whether the water pressure is too low, if the water pressure is too low and the Sakura gas hot water does not ignite without prompting the problem, then you can install a supercharger at home.
-
1. What are the reasons why the Sakura water heater suddenly does not turn on? 1. The electric water heater is not energized due to the broken power socket. 2. When the electric water heater is not filled with water, the electric water heater will not be energized due to the burning wire.
3. The plug of the current electric water heater has a leakage protector, plug in the plug, the leakage protector is displayed, if not, check whether your electric water heater is leaking! There is also a reset switch on the leakage protector, press it to see if the display stove light will be on. 4. The overtemperature (the element with four feet connected to the power cord) is faulty, resulting in the electric water heater not being energized
Firmly press down on the reset actuator in the middle of it. 5. Power board: check whether the fuse is disconnected (on and off with a multimeter) and whether the transformer is damaged (with a multimeter for primary on/off) resulting in the water heater not being powered on.
15 Second, what is the situation when the Sakura water heater suddenly does not turn on? 1. Check with an electric pen whether there is electricity on the plug-in board. 2. Check whether the power cord of the water heater is broken.
3. If there is no problem with the first two hidden elders, plug in the plug and press the small pimple on the plug. 4. If there is still no power, it may be that the fuse on the main board of the water heater is burned, or it may be that the motherboard is burned. 3. How to solve the sudden failure of the Sakura water heater?
1. The lack of sufficient power supply voltage is one of the reasons why the water heater is not energized, and its treatment method is also simple, detecting whether there is an open circuit problem in the socket, power cord, and power cord plug used in the water heater. 2. If the power socket is broken, replace the power socket directly, and there is no need to repair it with wheels, otherwise it will not last long. 3. Check the power board, check whether the fuse is disconnected (on and off with a multimeter), and whether the transformer is damaged (with a multimeter for primary on/off); A fuse or transformer needs to be replaced.
4. There is no water heating in the water heater, which directly leads to dry boiling, the thermostat trips, and the temperature control reset needs to be carried out; If you don't know how to deal with it, just look at the content below. 5. The water heater leakage protector trips, causing the water heater to not be energized, and after resetting, restart the water heater to let it return to normal.
-
Reasons and solutions for the heating indicator light of Sakura water heater not to light up 1, the power supply failure or poor contact will make it not light, the water heater is in dry boiling Changjingsheng or the water temperature of the water heater itself is too high, the electric heating pipe is damaged, and the internal components leakage will make the reset button pop up, and start the leakage protection to make it power off. X000B 2. First check the plug and socket with an electric pen to see if the contact is good. Then fill it with water and press the reset button again and it will return to normal work.
If the thermostat or electric heating pipe fails, the components should be updated in time. X000B 3, the electric pen can check whether the water heater leakage caused by tripping and the indicator light is not on, if the leakage is found, the internal components need to be replaced in time with the same type of components, try to eliminate the leakage to make it return to normal state. If you are worried about the electric shock accident of the elderly, you can contact professional after-sales personnel for corresponding inspection and component replacement.
4. Most of the life is caused by operation errors, such as dry boiling of water heaters and water ingress into the power supply. Therefore, we must pay attention to the maintenance and cleaning of the water heater, clean the sewage valve regularly, and check the inner tank and various parts during the change of seasons to ensure that the water heater is in good condition and prolong its service life.
Occupy a position, my water heater of the same brand as the landlord, the night before yesterday also had the same problem as the landlord, and it was also washed well, and when I opened it to rinse after wiping the shower gel, it couldn't catch fire, and I was very depressed, so I flushed it with cold water! Because there was something yesterday and today, it hasn't been repaired yet, so let's see if the landlord can encounter any good way! (Yesterday's). >>>More
My AO Smith water heater has been used for 5 years, has been leaking, and can not be repaired after sale, and then saw on the Internet that Haier's water heater has a very good reputation, so I bought Haier's water heater, the next day Haier's master installed it, only to find that the old water heater could not be removed because of rusty bolts, at that time I and the master were desperate, and finally the master took out an angle grinder from the toolbox, and it took almost three hours to remove the old machine, and then installed the new water heater, during which the master did not complain, Finally, he also said that the dismantling of the old machine is free of charge, and there is no service fee. Kudos to Master and Haier.
How to choose an electric water heater:
1. When choosing an electric water heater, consumers should choose a brand electric water heater. Choosing a brand electric water heater can better solve the "safety" point, the general brand electric water heater will have a built-in patented anti-electric wall technology, real-time safety protection, not only to solve the problem of leakage of the product itself, but also to completely eliminate all the hidden dangers of electric shock caused by the live ground wire, and cut off the hidden danger of electric shock. >>>More
Before cleaning the water heater, cut off the power supply, use the impact force of water to clean the water heater, drain all the water in the water heater before cleaning, and then tear off the hardware such as the shower, leaving only the cold and hot water pipes, and then install one end on the faucet, and the other pipe is used for drainage. Repeat it a few times to clean the water heater. Regularly carry out system sewage discharge to prevent pipeline blockage; And clean the water tank to ensure that the water quality is clean. >>>More
The light of solar energy is early, but the sales have not been good, and the coverage rate is not high. >>>More