-
A big search. Kiss you to try.
-
The first step is to enter the clinical menu, and the ventilator clinical menu can only be unlocked through a key combination, and the ResMed ventilator S9 series unlock needs to press and hold the two buttons as shown above for five seconds to enter the clinical menu. The second step is to adjust the language to Chinese If your ventilator is brand new, then the default language of the new machine is English, so for the convenience of operation, you need to adjust the ventilator operating language to Chinese. After entering the clinical menu, rotate to the icon of the "wrench" logo through the right knob key, then press the knob key down to enter the menu, select the first option, press the icon to turn yellow, rotate the knob key to find "Chinese Simplified" and press the knob key again to complete the setting.
The third step is to set the parameters of the ventilator 1Mode settingS9 Auto Set ventilator has two modes, namely "Autoset" mode and "CPAP" mode, it is recommended to choose AutoSet automatic mode, CPAP belongs to constant pressure mode, it is generally not recommended to choose, since I chose this model, I think it is for the automatic mode. (Note:.)
After the S9 ventilator enters the clinical menu, the parameters are adjusted through the knob key, pressing down is the meaning of determining and entering, and the left and right rotation is the meaning of selectionMaximum pressure settingBecause the S9 Auto Set ventilator is a fully automatic model, theoretically the maximum pressure can be set to 20 maximum, but sometimes users will have difficulty expiring, waking up, and hyperventilation at night, so if you have no problem using it, then you can adjust the maximum pressure to 20, if you have the above uncomfortable symptoms after use, it is recommended to reduce the maximum pressure appropriately according to your own situation. 3.
The minimum pressure refers to the pressure of the ventilator in your awake state, this pressure can not be set too high, because if the pressure is too high, the user will not be able to sleep, the minimum pressure is generally based on the user feels free to breathe, because this ventilator is a fully automatic model, the night will automatically change with the degree of airway obstruction, the minimum pressure is only an initial pressure of the machine, and its size has nothing to do with the effect of night use. 4.If you use a ventilator because the pressure of the ventilator rises too quickly and causes you to wake up, then you have to set a virtual state delay time, if there is no problem in this regard, then the maximum delay time can be turned off.
If the maximum delay time is set at 20 minutes, your inspiratory pressure will rise by a centimeter of water every five minutes, which has the advantage of not causing the ventilator pressure to be too high because you have apnea as soon as you fall asleep, causing you to be awakened by the airflow just after falling asleep. 5.Exhalation release Exhalation release means that the ventilator can automatically lower the pressure when you exhale, this pressure drop has three gears, one is the smallest, and the third is the largest.
-
Connect the DC power plug to the back of the S9. 2.Connect the power cord to the power supply unit.
3.Connect the other end of the power cord to the power output (outlet). 4.
Securely attach the air tubing to the air outlet. 5.Attach the assembled mask system to the air tubing.
2.Connect the power cord to the power supply unit. 3.
Connect the other end of the power cord to the power output port (socket) Kuanqing. 4.Securely attach the air tubing to the air outlet.
5.Connect the assembled mask system to the air tubing.
ResMed has a total of 4 buttons and an LCD panel, it is worth noting:1Press and hold the start stop button to power on, and hold the Zen head short press without starting to stop.
2.There are two ways to operate the spinner button, the first is to press the number of segments, and the second is to rotate. 3.
i button (also called information menu) to view relevant information4Set the button to change the settings.
-
*Three layers of protection ensure the ventilator's response to abnormal breathing and accurate pressure output1Equipped with the world's leading technology Dream Series mask.
2.Built-in database – accurately identify air leaks.
3.High air leakage compensation capability – provides accurate pressure output4Altitude Adjustment:
Automated* Platform Exponential Titration Automated Titration System 1Identification of abnormal breathing – to ensure that the best effect is achieved with minimum pressure and increase the comfort of the patient2Sensitive response to inspiratory restriction – the titrated pressure is true and accurate3
Responds to respiratory events, and the pressure gradually decreases after the breathing turns normal*Aviation-grade compressor - ensures stable, long-lasting, quiet pressure support* Ultra-quiet design - minimizes operating noise, less than 28 dB at 10cmH2O*A10 overpressure protection mode - protects against central hypoventilation or central apnea caused by the respiratory central nervous system to prevent further aggravation of the condition.
The real integrated design of heating - humidification and heating, increases the comfort and compliance of patients.
You can choose according to your own condition.
1. Indications for monolevel ventilators: sleeping snoring, sleep apnea syndrome. >>>More
It is not an effective method for the prevention of pneumonia associated with respiratory ventilation ()aReduces oropharyngeal and upper gastrointestinal colonization. >>>More