The air conditioner displays E6, which means that the air conditioner has a communication failure and needs to be repaired by professional maintenance personnel.
Professionals repair by the following methods:
1. Check whether there are obvious welding quality problems in the welding of the circuit components at the bottom of the electronic control motherboard or display board, and replace them accordingly if they exist.
2. Check whether the display board connection line group is broken or damaged, and check whether the plug connector of the display board connection line group is good, if there is a problem, replace or adjust it accordingly.
3. Use a working cabinet indoor motherboard to replace the original faulty cabinet indoor motherboard; If the air conditioner fault disappears, it is judged that there is a fault in the main board of the air conditioner; If the communication between the motherboard and the display board is still faulty in the air conditioner, it can be judged that the air conditioner display board is faulty.
4. Use a cabinet indoor display board that can work normally to replace the original faulty cabinet indoor display board, if the air conditioner is still faulty, it is judged that the main board of the air conditioner is faulty; If the air conditioner fault disappears, it means that the display board of the air conditioner unit is faulty.
-
Hello, the number 06 appears on the air conditioner, your should be the power disconnection or the condenser is blocked, that is, the pipeline is not passable, in layman's terms, it is the fault code caused by the different roads, thank you, I hope it can help you.
-
Many times it is difficult to say this clearly, and it is not difficult to operate in the field, which is thousands of dollars.
-
03 Error** usually indicates compressor overload protection for outdoor units. This can be due to one of the following reasons:
1.The power supply voltage of the outdoor unit is unstable or the power supply line is faulty.
2.The overload of the compressor may be due to the internal failure of the outdoor unit or the blockage of the pipeline between the outdoor unit and the indoor unit.
3.The fan of the outdoor unit is faulty, causing the internal temperature of the outdoor unit to be too high.
If your Yangzi air conditioner has 03 error**, it is recommended that you turn off the air conditioner immediately and contact a professional air conditioner maintenance staff for inspection and repair. Do not attempt to repair it yourself to avoid causing greater damage or safety hazards.
-
Fault**: e6
Fault content: Indoor temperature sensor failure.
Cause of failure: 1. The sensor pin is loose or in poor contact.
2. The sensor is damaged and the resistance value is wrong.
3. The control circuit board is faulty, and the control signal cannot be received and sent.
It is recommended to find a professional maintenance personnel to check it.
-
Fault display: prompt 03 fault**, the air conditioner is not refrigerated, or does not start.
Fault content: communication failure of indoor and outdoor units.
The original source of the fault is the cause:
1.The control board prongs are loose or in poor contact.
2.The internal machine Xunheng circuit control board is faulty.
3.The controller circuit board is faulty and cannot receive and send control signals.
-
Fault**: e6
Fault content: Indoor temperature sensor failure.
Cause of failure: 1. The sensor pin is loose or in poor contact.
2. The sensor is damaged and the resistance value is wrong.
3. The control circuit board is faulty, and the control signal cannot be received and sent.
It is recommended to find a professional maintenance personnel to check it.
-
The display of Yangzi air conditioner is divided into different types and functions, and each has a specific meaning and use.
1.Temperature Display**: Displays the temperature inside the air conditioner in digital form, e.g. etc.
2.Mode display**: Shows the mode in which the air conditioner works, such as cooling, heating, air supply, etc.
3.Wind speed display**: Indicates the speed of air supply of the air conditioner in the form of numbers or symbols, such as high, medium, low, automatic, etc.
4.Timed power on/off**: Help users set the on/off time of the air conditioner, including timed power on, timed shutdown, etc.
5.Therefore, when the air conditioner fails, the sedan will be saluted and the corresponding fault will appear** prompt the sail bend.
6.Humidity Display**: Displays the humidity in the air, helping the user control the humidity of the indoor environment.
7.Outdoor Temperature Display**: Displays the temperature outside to let the user know about the external environment.
In short, the display of Yangzi air conditioner is very rich and diverse, providing users with a more convenient experience.
Air conditioning defrosting means that when the outdoor temperature is below zero, after the air conditioner absorbs heat, the metal shell of the air conditioner will briefly frost into ice. If not treated in time, the condensed frost will reduce the heat absorption effect of the air conditioner, thus affecting the heating production. >>>More
The air conditioner swings and turns the direction.
Kelon air conditioner is the air conditioning product of Hisense Kelon Electric, the company's products include Kelon air conditioner, Hisense air conditioner, Rongsheng refrigerator, Hisense refrigerator, Hisense washing machine. >>>More
It is the air conditioner with a device that produces negative ions, negative ions have the effect of air purification and health care, and now many household appliances claim to have negative ion functions, such as humidifiers, air conditioners, refrigerators, etc., for these electrical appliances this is just an additional function or a gimmick used to attract customers, negative ion products are best to choose professional products, such as the use of ecological negative ion generation chip technology, nanofullerene negative ion releaser technology negative ion machine, leading technology not only ensures the release of negative ions, It also ensures that the production is pure eco-grade small particle size negative ions, likeEcological anion generation technology with anion system and pollutant collection systemOn the basis of the first two negative ion technologies, the technical upgrade has been carried out, and the pollutant collection system has been added, which can not only generate high concentration of eco-grade small particle size negative ions and efficiently purify the air, but also adsorb and collect particulate pollutants combined with negative ions to improve the purification efficiency of negative ions.
For Gree air conditioner, it is impossible to know what the air conditioner fault is just by saying that the fault ** is rb. Because of the failure of Gree air conditioner**, the arrangement of different models of air conditioner is different and there is no rule. Therefore, if you know that the fault ** is RB, you should take the air conditioner model to search for the Gree air conditioner fault ** summary table to see which part of the fault is. >>>More
There is only a refrigeration function, not a heating and cooling air conditioner.