-
Spacing coefficient Scope of application.
Large cities, small and medium-sized cities, latitude (Beiwei) region.
32°30 All areas under the jurisdiction of Nanjing, Zhenjiang, Changzhou, Wuxi, Suzhou, Nantong, most of Yangzhou (except Baoying and Gaoyou), most of Taizhou (except Xinghua).
32°30 34° Northern Yangzhou (Baoying, Gaoyou), northern Taizhou (Xinghua), most of Yancheng (except Xiangshui), all of Huaiyin, most of Suqian (except Shuyang), southern Xuzhou (Suining).
34° Most of Xuzhou (except Suining), all of Lianyungang, northern Suqian (Shuyang), northern Yancheng (Xiangshui).
Note: If it is indeed difficult for some areas in the renovation of old urban areas to meet the specified standards, according to the current urban population, the coefficient can be reduced for small and medium-sized cities, and for large cities, and it should be expressly stipulated through the implementation rules of cities and counties"Localized"scope.
General requirements for northern cities: building spacing = building height x sunshine coefficient (to.
This is the requirement of floor spacing, and the general local standard is double floor height.
It's not just the quality of your house, it's also the lighting.
-
Trouble! Such a disgusting thing happened again!
m, I don't know what kind of foundation your house is, if it is a pile foundation, it should have little impact on the stability of your house. But if it's an old house, it's hard to say. In addition, if he excavates from meters, then it is not necessarily only meters from your house, it may be basement support or other facilities.
There is also the problem of lighting in your home. But it's hard to say, I don't quite understand what your southwest rice means? If you go further southwest from the southwest corner of your house, it won't affect you. In short, this is a technical job, and you have to look at the picture to determine.
This law does not say, but the technical regulations say, if he is in accordance with the approved drawings (the construction drawings are to be stamped and signed by the design institute, and the construction drawing review company reviews the qualified report), it is useless for you to find him, you can only find the management department, such as the planning bureau, may have to administrative litigation, you look at the "Administrative Litigation Law". If he didn't come according to the drawings (unlikely), then hurry up and talk to their stewards first.
Good luck.
-
It is true that both parties must sign before construction!!
-
First, there are very detailed regulations on the spacing of adjacent buildings, etc., if they do not meet the requirements of the regulations, they will not pass the construction approval, and even if the construction is completed, it is an illegal building. If the building in front of your home is about to start has legal procedures, it means that the relevant regulations are met.
3. Theoretically, in the case you described, it should be calculated that the two buildings are neither parallel nor perpendicular, and when the angle between the two buildings is greater than 30 degrees and less than 60 degrees, the spacing at the narrowest point cannot be less than 70% of the height of the building located in the south position.
-
Houses. Even if it's built together. I guess no one cares.
-
What are the 9-storey and 11-storey buildings? The spacing between residential and public buildings is not the same. What is the fire resistance grade? The spacing varies depending on the grade.
If they are all residential buildings, the houses are multi-storey buildings, and according to the existing regulations, the distance between the 9th floor and the house is 6 meters for the first and second class fire resistance grades. The distance between the 11th floor and the private house is 9 meters.
-
Building spacing as prescribed by the Building Act.
1.Definition of building spacing: Building spacing refers to the horizontal distance between the exterior walls of two buildings, and urban planning, especially in detailed planning, has very strict requirements for building spacing.
2.Technical Principles of Building Spacing Building spacing as prescribed by the Building Law.
It is mainly determined according to the comprehensive consideration of sunshine (north-south building), ventilation, lighting, noise and line of sight interference, fire prevention, earthquake prevention, greening, pipeline burial, building layout form, and land conservation.
The layout of the dwelling is usually based on meeting the requirements of sunlight as the main basis for determining the building spacing.
The Code of the People's Republic of China for the design of building fire protection stipulates that the spacing between multi-storey buildings should be at least 6 meters, 9 meters between multi-storey buildings and high-rise buildings, and 13 meters between high-rise buildings. This is mandatory.
3.Design standards.
According to national regulations (design specifications), the sunshine time of the winter solstice is not less than 1 hour (the lowest window of the house) as the standard. The spacing is the height of the building from the exterior of the building to the eaves of the house, tan(a).
a- Angle of solar elevation at noon on the winter solstice. It can also be calculated using the ratio of: building height: building spacing = 1: .
Regarding the spacing between buildings, there are also the following relevant regulations.
The spacing of non-residential buildings, except as otherwise provided in the approved detailed plan, shall comply with the following provisions:
1) When multi-storey is arranged in parallel, the spacing shall not be less than a multiple of the height of the higher building, and shall not be less than 6 meters; When arranged vertically, the spacing should not be less than 9 meters, and the spacing of gables should not be less than 6 meters.
2) When the high-rise buildings are arranged in parallel, the building spacing shall not be less than the times of the height of the higher building, and shall not be less than 20 meters; When arranged vertically, the spacing between its buildings is not less than 18 meters. The distance between gables should not be less than 13 meters.
3) When multi-rise and high-rise are arranged in parallel, the spacing shall not be less than 18 meters, and when arranged vertically, the spacing shall not be less than 13 meters. The distance between gables should not be less than 9 meters. The above is the regulation of building spacing.
The spacing between residential buildings and non-residential buildings shall meet the following requirements:
1) The sheltered building is a residential building, and it shall be controlled in accordance with the provisions on the spacing of residential houses.
2) The blocked building is a non-residential building, which shall be controlled according to the spacing regulations of non-residential buildings, and the influence of visual hygiene factors shall be considered.
3) The spacing between the gables of multi-storey buildings should not be less than 8 meters, the spacing between the gables of high-rise buildings should not be less than 13 meters, and the spacing between multi-storey and high-rise gables should not be less than 9 meters. These are all rules on the spacing of houses.
There are legal regulations on the spacing of buildings, and the comfort of living and working is the criterion, and if it is not in accordance with the regulations, the construction approval will generally not be passed.
-
The minimum safety distance required for the building should be times h.
h refers to the height difference between the bottom surface of the foundation of two adjacent buildings.
Of course, this regulation is only considered from the perspective of technical security.
Poor soil quality should be calculated as 2 times.
You mentioned that the foundation depth of public housing is about 6 meters, and if the depth of the bottom surface of your house is only 5 meters, the minimum distance should not be less than 2 meters, then they are violating the technical regulations.
-
If there is a landslide, it is recommended that you report it to the local competent BAI department.
For specific legal or not, please refer to the relevant ZHI building code.
Check it out for yourself and see it for yourself.
-
You should also consider the issue of daylighting (i.e., the tangent of the height of the building multiplied by the maximum angle of the local sun's elevation).
-
We used to have more than closer
-
The distance between the two floors should be 16 meters according to the lighting requirements.
-
There is a high-rise building built in the southwest of the house, and there is a certain attention to feng shui. From the perspective of feng shui, the southwest high is called the mother killing pillar in feng shui, which is not good for the heroine of the family and is prone to diseases. At the same time, a certain distance needs to be maintained between high-rise buildings and residences to ensure sufficient sunlight.
According to the regulations of the Ministry of Housing and Urban-Rural Development, the spacing between buildings should be the total height minus the height of the window sill on the first floor multiplied, but in practice it is difficult to meet this standard. Therefore, if there is a high-rise building in the southwest of the house, and the spacing between the buildings is not enough, it will affect the exposure to sunlight, which will affect the lighting and living environment of the house.
To sum up, if there is a high-rise building in the southwest of the house, you need to pay attention to whether the spacing between the buildings is sufficient, as well as the attention to feng shui. If the spacing between buildings is insufficient or you are particular about feng shui, you need to consider the choice of other locations or layouts.
-
Case-by-case analysis.
How far away is the southwest corner building from your home, and whether it is within sight. If there is a main room such as the master bedroom or living room that can be seen by people in the southwest corner of the building, if others can easily see what you are doing every day, you always have to close the doors and windows and close the curtains, of course, that is not good.
Whether the building in the southwest corner is a glass curtain wall.
Buildings, if they are, may have light pollution.
What is the nature of the building in the southwest corner and whether there is noise pollution.
Does the southwest corner building have sharp corners on your home, if so, the feng shui is not good.
-
It mainly depends on whether the high-rise building blocks the light on the floor you are in, how far away it is from the building you are in, and if it does not affect the lighting and ventilation, it has nothing to do with it.
-
In fact, the spacing of buildings is controlled by the following factors:
1. Mainly the sunshine spacing. The building on the south side will block the sunlight of the north-facing building, so the planning must control the spacing and calculate the sunshine to ensure that the building on the south side can still ensure that the house on the north side has the specified sunshine on a cold day or winter solstice.
2. Fire spacing.
3. Planning points.
Generally speaking, as long as the above aspects meet the requirements, it is reasonable and legal. Otherwise, it is an infringement or violation.
As far as your specific situation is concerned, the spacing between the two high-rise buildings is 60m, and the 20th floor is 60m high, which achieves a spacing ratio of 1:1, which meets the requirements. There should be no problem with the calculation of sunshine (this point needs to be calculated specifically, the design unit will generally calculate, and the ** department will also review).
The fire spacing also meets the requirements. So there is no problem.
The relationship between the new high-rise and the old private house. 1: The new high-rise is on the north side, which will not affect the sunshine of the old houses on the south side.
2. The distance between the new high-rise and old buildings is greater than 10m, which meets the requirements of fire spacing.
3. The red line of the new high-rise setback land of 10m must be designed according to the planning points of the Planning Bureau, and it should also comply with laws and regulations.
Your understanding of the concession of 23m and 32m and so on is not correct.
The spacing is needed to be met at the same time. , but not cumulatively. It can't be said that the sunshine needs 20m, the firefighting needs 13m, and the total is 33m.
The only thing that may be controversial at the moment is whether the distance between the high-rise building and the old private house is 13m. That is to say, the distance between the old house and the wall is not 3m... But even without 3m.
It should also be the time when the old house was built, and the distance that should be retreated was not sufficient. Because the land of the two common borders requires both sides to retreat... Therefore, even if this point is pursued, it is relatively difficult to achieve any results.
-
Depending on your situation, the fire spacing between the buildings in this design is fine and has no effect on your sunlight, while the sunlight of the new building needs to be calculated to determine (the east-west building is unknown, which will affect the sunlight), and the main impact on you is the interference of your line of sight.
-
1.Looking at the specification, the building sunshine coefficient of Foshan City is 1:, that is, the ratio of floor height to building spacing.
The requirement to ensure that the building spacing is to be able to achieve an hour of lighting on the day of the winter solstice, you are two floors, at most 7 meters high, the spacing is only one meter, and the current spacing is enough.
2.The two 20-storey buildings in the north and south left 60 meters, which is enough. The technical regulations are calculated in this way, 24+, calculated according to the height of 3 meters, H is 60 meters, and finally the building spacing is 33 meters, only 33 meters is on the line, 60 meters is very wasteful.
-
The spacing between buildings should be at least a multiple of the height of the building.
-
Foshan City Urban Planning and Management Technical Regulations are referred to, which is very detailed.
-
The scope of the highway construction control area, the distance from the outer edge of the highway land to the outside of the standard is: the expressway is not less than 30 meters.
Houses in the control area and outside the red line do not have to be demolished; Those who have affected the safe exercise or the production and life of residents may negotiate with the highway construction and management department to obtain compensation or demolition.
Regulations on the Protection of Highway Safety
11th local people at or above the county level shall, in accordance with the principle of ensuring the safety of highway operation and the need for highway development, organize the departments of transportation, land and resources to delineate the scope of highway construction control areas.
The scope of the highway construction control area, the distance from the outer edge of the highway land to the outward is as follows:
1) National highway not less than 20 meters;
2) Provincial roads not less than 15 meters;
3) The county road is not less than 10 meters;
4) The village road is not less than 5 meters.
If it belongs to a highway, the scope of the highway construction control area shall not be less than 30 meters from the outer edge of the highway land.
The scope of the building control area on the inside of highway curves, interchanges and level intersections shall be determined according to the requirements of safe sight distance.
13th in the highway construction control area, except for the need for highway protection, it is forbidden to construct buildings and ground structures; Highway construction control areas have been legally built before the demarcation shall not be expanded, due to highway construction or to ensure the safety of highway operation and other reasons need to be demolished, shall be compensated in accordance with law.
Buildings, ground structures and other facilities constructed outside the highway construction control area shall not obstruct highway signs and shall not obstruct the safe visual distance.
-
As long as the new expressway is not within the red line, there is no restriction on existing houses, but in the future, no new permanent buildings are allowed within 100 meters on both sides of the expressway. You can only be said to be unlucky in this situation.
-
Newly built houses must be 40m away from the highway, but new highways do not have this restriction for existing houses. In other words, a new highway can be built next to a house.
If the house is damaged due to the construction of the expressway, it can be reported directly to the construction party, and if necessary, a lawsuit can be filed.
The essential difference between Layer 2 and Layer 3 is whether multiple int vlanif interfaces can be configured, which can be a Layer 3 switch, and those that can only configure one int vlanif are usually called managed switches, and those that cannot be configured with int vlanif are called ordinary Layer 2 switches. The details are as follows: >>>More
Go to the rural feng shui and a professional feng shui master will serve you.
Prunes are a little better.
Prunes from California are rich in vitamins A, C, fiber and antioxidants, which are important nutrients for strengthening bones and teeth, healthy skin and hair, maintaining youthful vitality and slowing down aging. >>>More
Inside; Layer 3 networks need to use IP routes to implement cross-network segments. >>>More
Absolutely.
The cosmetic effect of tomatoes. >>>More