Trip. It is generally the switch behind the meter or the air (leakage) switch in your home.
1.The switch trip behind the meter is generally caused by your household electricity load exceeding the reported installed electricity capacity, it is recommended that you apply for "capacity increase" to the power supply company, and you can pay attention to and bind the "China Southern Power Grid" specifically.
95598 "Official Platform" "My Electricity" "Business Handling" "Business Change" Select "Capacity Increase" Fill in the handling information, handler information and SMS verification code, and click "Confirm".
2.The air (leakage) switch trips generally because of the air switch.
The rated current is too small to meet your household electricity load or your household appliances have leakage and short circuit, it is recommended that you entrust a qualified electrician to check for you.
We hope you find ours helpful.
-
First of all, it is necessary to distinguish whether it is a leakage protection trip or an overload trip, which can be seen from the tripping switch, the possibility of leakage is large, there may be a line, there may be an electrical appliance, it is said that the power consumption during this period of time will increase the power grid voltage, and some bad lines or electrical appliances will leak due to the increase in voltage. During this time, unplug all electrical appliances, turn off the switches if they are not plugged, and check them overnight if they don't jump.
If it is also a line problem, in the case of pulling down the door switch to ensure that the zero line live wire is out of the power supply, use a 500V shake meter to measure the insulation resistance of the indoor live wire to the zero line and the live wire to the ground wire, and find out the fault part and replace the bad line in sections.
Some electrical appliances started with micro switches will consume electricity as long as they are plugged into the power supply, and there is also the possibility of tripping, such as range hoods, electric water heaters, electric fans, remote control lights, etc.
If it is the neutral line to the live wire leakage, it may cause overload tripping, and the electric meter must be taken away without electricity at ordinary times.
-
The meter tripping may be because the wire in the switch is not firmly connected, so the line is short-circuited and tripped. It is also possible that the load of electricity exceeds the rated current and trips. It's also possible that a line or appliance in your home has leaked, causing the meter to trip.
How to solve circuit tripping.
1. First of all, we should figure out which air switch is and which one is the leakage protector, in fact, you can see from the appearance that the volume of the general leakage protector is relatively large, and the volume of the air switch is relatively small. After figuring out the two of them, press the two switches at the same time, and then start to push up one button at a time, and the first thing to push is the leakage protector.
2. If it is found that the leakage protector cannot be pushed up, it means that the leakage protector has failed, and then the leakage protector needs to be replaced. If the protector is pushed up and tripped, it means that it is a problem with the line.
-
The wires in the switch are not securely connected or there is a leakage of electricity from a line or appliance in your home, causing the meter to trip.
If there is no problem, you can directly press the blue small press on the electric board and then close the switch to restore the electricity.
If we find that the home has not been connected to electricity, then it means that our fuse is burned out, at this time we need to call the local power supply company**, call professional personnel to come and repair.
If we can't determine the specific cause of the meter tripping, we can also directly find professional personnel to repair it, and we must not do it ourselves, otherwise it will be electrocuted and threaten our lives.
-
The air opening at the meter is always tripped, one may be a fault point on the line, the other may be the air open aging, resulting in its internal insulation deterioration, first remove the line at the back end of the air open, directly open the air up, if the air open or will trip, that is the problem of the air open, need to replace the air open, if the air open is no problem, and then check the fault point on the line.
-
The meter often trips, and the main bai should have the following reasons: du
First, the installation is poor
If the lead wire of each pile head is not firmly connected, it will cause the pile hair to heat and oxidize, burn out the outer insulation of the wire, and emit sparks and burnt smell, resulting in undervoltage of the line and air switch action.
2. The leakage switch does not match the load.
The actual electrical load of the household is greater than the rated current of the low-voltage circuit breaker on the line. It generally occurs after the installation or addition of high-power household appliances such as air conditioners and electric water heaters. The matching air switch must be replaced.
3. Leakage and short circuit of electrical appliances or lines.
When it is found that the electrical appliances used are leaking, as long as you unplug the electrical appliances with leakage faults, and then close the low-voltage circuit breaker again, you can send electricity. After the low-voltage circuit breaker jumps open, first disconnect all the branches, and then close the power transmission one by one. When a certain circuit is closed, the low-voltage circuit breaker cannot be powered, that is, the shunt is faulty, and this road should be disconnected and other shunts should be closed for power transmission.
After the problem of faulty shunting is detected, the power is sent after repair.
Extended Information: Circuit Trip Resolution:
1. After the leakage protector trips, a button will pop up, and it can be closed again by pressing it.
2. It is indeed a place where there is leakage, so check it. At the same time, many leakage protectors also have air switches, you look at the power and short circuits.
3. The leakage protector is broken. All the sockets in the house are divided into two leakage protectors, but one of them is often tripped, and then all the lines of this one are connected to the other switch, and they never skip again.
-
Is it a prepaid meter? Describe it in detail to help you analyze.
-
Summary. Hello dear and happy to answer your <>
The way to trip the meter outside the house is to first open the outer box of the meter, and then there is a blue button in the lower right corner of the meter, just press the button; If the wire is overloaded and tripped, you only need to open the electrical box at home, and then push the empty gate up, if you can't push it up many times, then you need to press the button of the leakage protection device, and then push it up. What are the reasons for the tripping of the electric meter 1, the short circuit of the wire, this is a very common situation, the electrical appliances at home are damaged, resulting in tripping, you can turn off the power supply of the electrical appliances, and then check them one by one, and then take the short-circuited electrical appliances of the wires to repair, and restore the electric switch. 2. If the power load exceeds the standard, it will only occur when multiple high-power electrical appliances are used at the same time, so try to avoid using multiple electrical appliances at the same time, or buy a meter with a larger load.
3. The voltage is unstable, the voltage is unstable, and the surrounding residents will have a similar situation, which can be reflected to the power department and asked to solve the problem, or purchase and install a voltage regulator, so that when the voltage is unstable, it can also protect the electrical appliances. I hope this service can help you, you can click on my avatar to follow me, and if you have any questions in the future, you can consult me again, and look forward to serving you again. Wishing you well; Happy life, everything goes well [warm] [warm].
The meter outside the home tripped.
Are you there. Hello dear and happy to answer your <>
The way to trip the meter outside the house is to first open the outer box of the meter, and then there is a blue button in the lower right corner of the meter, just press the button; If the wire is overloaded, you only need to open the electrical box at home, and then push the empty gate upward, if you can't push it up many times, then you need to press the button of the leakage protection device, and then push it up. What are the reasons for the tripping of the electric meter 1, the short circuit of the wire, this is a very common situation, the electrical appliances at home are damaged, resulting in tripping, you can turn off the power supply of the electrical appliances, and then check them one by one, and then take the short-circuited electrical appliances of the wires to repair, and restore the electric switch. 2. If the power load exceeds the standard, it will only occur when multiple high-power electrical appliances are used at the same time, so try to avoid using multiple electrical appliances at the same time, or buy a meter with a larger load.
3. The voltage is unstable, the voltage is unstable, and the surrounding residents will generally have a similar situation, and they can report to the power department and ask to solve the problem, or buy and install a voltage regulator, so that when the voltage is unstable, it can also protect the electrical appliances. I hope this service can help you, you can click on my avatar to follow me, and if you have any questions in the future, you can consult me again, and look forward to serving you again. Wishing you well; Happy life, everything goes well [warm] [warm].
-
Solution:1First of all, you have to figure out which is the air switch and which is the leakage protector.
In fact, you can see it from the outside. Generally, the volume of leakage protector is relatively large, and the volume of air switch is relatively small. Once you've figured out the two of them, press both switches at the same time, and push them up one by one.
The first thing to push is the leakage protector.
2.If it is found that the leakage protector cannot be pushed up, it means that the leakage protector has failed, and the leakage protector needs to be replaced. If the protector is pushed up and tripped, it means that it is a problem with the line.
3.But when the air switch can't be pushed, the indoor plug needs to be unplugged. If it still can't be pushed, it means that the neutral line of the circuit needs to be separated from the ground wire. At the same time, it is also necessary to check whether there is leakage in the live line.
4.Finally, use a measuring pen to test whether there is an image of power transmission in the circuit. If there is a high-power electrical appliance, there is no power transmission between the ground wire and the neutral line.
-
1.When your electricity consumption is greater than the current that the meter is subjected to, the meter will automatically trip because the meter has an automatic protection function.
2.When your wires are aging and there is a short circuit, the current is very, very large. The meter also trips automatically.
-
The reason for the tripping of the leakage protector at the meter is: 1. The oxidation or crimping at the wiring of the meter and the leakage protector is not tight, resulting in the heating tripping at the wiring. 2. The meter and leakage protector are scrapped.
3. If there is a leakage or short circuit fault in the line connected from the leakage protector, or a short circuit in household appliances, it will cause the leakage protector to trip. For a few reasons.
-
Short circuit or this is overload, excessive current.
-
What is the reason why the main power switch at home keeps tripping? Here's why:
1. There are too many high-power electrical appliances connected, or the power of the electrical appliances used at the same time is too large, resulting in circuit load, in order to avoid fire accidents, the circuit will be automatically protected, and the main power switch will trip. It is necessary to look at the total power of the circuit, and the power of the electrical appliances used cannot exceed this value, otherwise it will cause tripping.
2. The circuit in the circuit is aging, or the components are damaged, short circuited, etc., and even cannot be pushed. For the sake of electricity safety, it is best to find a professional electrician to come to check, and do not do it yourself to avoid electricity accidents.
3. Excluding the above two problems, it may be that the voltage is unstable due to excessive pressure in the main electrical box of the building; It is also possible that the wiring of the main electrical box is aging. These are all things that need to be overhauled by a professional electrician, and must not be operated blindly.
The main switch of the power supply at home always trips, and the solution is as follows:
1. First check the position of the main power switch tripping, if the branch switch trips, it may be because too many high-power electrical appliances are connected to the same branch switch, and exceed the maximum carrying power of this branch, at this time, the line of some high-power electrical appliances needs to be connected with other branch switches.
2. If the main switch of the power supply trips, the total power of the electrical appliance needs to be calculated to see whether it exceeds the maximum power that the main switch can carry. If the total power of the electrical appliance exceeds the loadable power of the air switch, the use of high-power electrical appliances should be reduced, and at the same time, an application should be made to the power supply bureau to increase the total switching capacity.
3. If the total power of the electrical appliance does not exceed the maximum power that can be carried by the main power switch, the main power switch needs to be replaced with a new one after the main power switch trips.
The above is for "What is the reason why the main power switch at home always trips?" The main switch of the power supply at home is always tripping solution", to avoid causing safety accidents, I would like to remind all friends, please ask a professional electrician to come to check and repair.
-
1.It may be that the power of the line is short-circuited, the power of the air switch does not match the high-power electrical appliances, the wiring of the wire is loose or the contact is poor, etc., which causes the switch to always trip.
2.If the load power of the air switch configured in the home is relatively small, the air switch with large load power needs to be replaced.
-
What's the matter with the electric switch that keeps tripping.
-
Check whether there is a lot of power at home, if it is recommended to turn it off, there is also to check whether the wire is aging, increasing resistance, causing tripping.
-
If the meter keeps tripping, it may be that the structure is not very good, or there is a problem with the fuse.
-
The meter trips to indicate that there is leakage or short circuit, but it does not trip during the day, in this case, first check the external circuit, which may be caused by overvoltage or undervoltage at night! If the external line is confirmed! Then focus on checking whether the electrician has reversed the zero ground!
-
Leakage, quickly find an electrician to check the line.
Reading method: according to the size of the measured resistance, the watch hand stops at a certain position of the ohm scale mark (the top one marked with a scale mark), observe the value indicated by the watch hand at this time, and then multiply by the gear where the gear selector switch is located, that is, the resistance value of the resistor. >>>More
1. Check whether the remaining amount of the smart meter is zero or reaches the set lower limit, if the remaining amount of the smart meter is zero or has reached the set lower limit, the power supply may be cut off for the user, and the trip indicator will be always on. >>>More
The meter is a measuring instrument and will not significantly affect the measurement due to the size of the range. >>>More
Instructions for the use of multi-meter: multi-meter is a kind of instrument commonly used in laboratory and life, although its range and accuracy are different, but the use method is exactly the same, the following is an example of the elective 3-1p69 diagram of the people's education version, and the use of multi-meter methods and precautions: >>>More
According to the current policies and business rules, if you are a customer of Guangdong Power Grid Company, you need to terminate the use of the meter, settle the electricity bill and cancel the account, and the information required for the cancellation of the account is as follows: >>>More