It may be that the pipeline is bent Most of the low-pressure pipes are deflated It is the thick one You are looking for someone to see if you know that the general cabinet has a liquid storage tank inside the cabinet, which reduces the gas reflux and the impact noise on the compressor during work But it is not completely absent... But it's not going to be very loud, so you can find someone to take a look.
-
Compressor thermal protection.
Wait a few hours for the compressor to cool down on its own before turning it on. If it doesn't work, change it.
-
As I told you, you can't fix it yourself, so let's find someone who repairs the air conditioner to repair it.
-
Analysis of the causes of non-refrigeration and solutions:
1. Whether the air-conditioning compressor is working normally, whether the fan is started, check whether the air-conditioning compressor, the starting capacitor and the fan are damaged, and check and eliminate.
2. Whether the air conditioner radiator is dirty and blocked, resulting in the air conditioner not being able to dissipate heat in time, causing the air conditioner to suddenly not refrigerate the fault, and the air conditioner radiator should be cleaned regularly.
3. Detect whether the air-conditioning system is deficient in fluoride and add fluoride to the air-conditioner in time. Check the method, turn on the machine first, after the compressor of the air conditioner runs continuously for 30 minutes, touch the condensing louver fan behind the air conditioner with your hands, if the temperature is not cool or hot, and the compressor is still working, it is likely to be fluorine leakage and lack of fluorine.
4. Check whether the temperature sensor of the air conditioner is damaged, whether the remote control and receiver are out of order, which are all reasons for the sudden failure of the air conditioner, please check and rule it out.
-
Lack of fluorine, or the compressor is not started, check the external machine!
-
Chunlan air conditioner compressor light is on due to the following reasons:
1.Compressor overheating: Compressor overheating can cause the lights to come on, which can be caused by the air conditioner running for a long time or poor air circulation.
2.Compressor failure: Failure of the compressor can also cause the lights to turn on, which may be caused by damage to the internal parts of the compressor or faulty compressor circuitry.
3.Faulty circuits: Faulty air conditioning circuits can also cause lights to come on, which can be caused by a short circuit or poor circuit contact.
If you encounter this situation, it is recommended to contact professional air conditioning maintenance personnel in time for rock maintenance and maintenance.
-
The compressor image appears when the Chunlan air conditioner is turned on, and the compressor image is no longer when the external unit stops in a few seconds.
Kiss. Hello, I'm glad to answer for you: Chunlan air conditioner turns on the compressor image, and the compressor image stops in a few seconds.
The compressor's overload protection will jump, which means that the high voltage of the system is too high or the overheating current is too high. Reduce the refrigeration dose appropriately. Appropriately reduce the amount of refrigeration.
Check the condenser tube for dirt and clean the condenser. Judge, eliminate, and re-process according to the pressure gauge track. I hope mine is helpful to you, I wish you a happy life, if mine is helpful to you I hope you can give a 5 star like.
-
1. The air conditioning compressor does not work - freon is insufficient.
Reason: Air conditioning compressor not working is generally caused by the lack of freon as an air conditioning refrigerant.
Solution: Replenish the air conditioner with freon.
2. The air-conditioning compressor does not work - the installation is not standardized.
Reason: When the air conditioning system is not discharged, there will be ice blockage, which will increase the load of the compressor, and the increase of shrinkage load will cause the compressor temperature to increase, and the refrigeration oil will deteriorate at high temperature for a long time, which will not play the role of lubrication and cooling, and promote the compressor temperature to further rise, and the coil will be reduced due to high temperature insulation, resulting in the compressor being damaged and not working.
Solution: Strictly control the quality at the time of installation.
3. The air conditioning compressor does not work - the voltage is low.
Reason: The power supply is not connected or out of power, the power conductor socket is not in good contact, or the power conductor wire diameter is thin or aging, which will lead to low power supply voltage and cause the air conditioning compressor to not work.
Solution: Check whether the circuit is normal, and install a voltage regulator.
4. The air conditioner compressor does not work - function locking protection.
Reason: Some brands or models have a lock protection function, if you are in lock mode and cannot perform any operation, you can refer to the manual to cancel; If the compressor is working at high temperature for a long time, resulting in a decrease in insulation, a low coil resistance, an increase in the starting current, and an instantaneous increase in the temperature of the compressor, the air conditioner locking protection will also be activated.
Solution: Refer to the manual to unlock or ask a professional for help.
5. The air conditioning compressor does not work - the outdoor unit is too dirty.
Reason: The outdoor unit is too dirty, which will cause the air conditioner to dissipate heat poorly, increase the compliance of the compressor, and may damage the compressor for a long time, causing the compressor to not work.
Solution: Clean the outdoor unit.
There are many reasons why the air conditioning compressor does not work, if the air conditioning compressor at home does not work, even if you know which aspect of the problem is, it is recommended that the user find a professional to check and repair, the air conditioning compressor is more complicated, and unnecessary accidents may occur when repairing it privately.
-
One of the more common reasons is that the air conditioner has been used for a long time, so that the freon** inside the air conditioner is insufficient, so the air conditioner compressor does not work.
2. There is also the fact that the air-conditioning compressor works under load for a long time, and the current is too large, so that the surface temperature of the air-conditioning compressor will rise, and the line card of the power supply line will be burned out after a long time, so that the air-conditioning compressor does not work.
3. You can check the power cord first, if the power cord is not in good contact or the power cord is not plugged in, it will make the air conditioner compressor not work.
4. Another reason is that during the installation of the air conditioner, the connecting pipe is bent, so that the compressor has been working under load, resulting in the air conditioning compressor not working.
-
This brand of compressor is easily damaged, and in the beginning, this brand of compressor has been in a damaged state.
And the chance of damage is very high, you can use a multimeter to measure the three terminals of the compressor to see if it is organized correctly.
-
There are many reasons for this, but the possible cause is the phenomenon of the compressor protection device tripping.
Compressor overload protection will trip, indicating that the system is too high-pressure, the pressure is too high, or the overheating current is too high.
Causes and elimination of high pressure and overheating:
1. Too much refrigerant. Appropriately reduce the amount of refrigeration on the sail limb.
2. Poor heat dissipation. Check the condenser pipe for dirt and dirt and clean the condenser.
3. The pipeline system is blocked. Refer to the pressure gauge to judge, eliminate, and re-process systematically.
4. Dust and fouling of the evaporator or filter screen. The airflow becomes smaller, the system pressure and temperature are unstable, and the evaporator or filter is cleaned.
5. Fluoride deficiency is also possible. When there is a lack of fluorine, the exhaust temperature of the pressure leakage macro shrinker will be overheated, which will make the overheating load protection switch trip.
The electrical problem is:
1. Control circuit board failure.
2. The temperature sensor is overloaded and the information is wrong.
3. The power supply wiring is loose and the contact is poor.
4. The starting capacitor or compressor starting coil is burned out.
The information is insufficient, it can only be analyzed in this way, and there are many other possibilities, it is recommended to find a professional car book maintenance personnel to check it.
Hope it can help you, satisfied. Thank you.
-
Summary. Chunlan air conditioner refrigeration is normal, but it does not stop. Is it a fault of the internal temperature sensing head?
Hello dear, 1There are many temperature sensors that need to be used on the air conditioner, among which the indoor temperature sensor is related to "shutdown", which is installed on the air conditioner. The air conditioner needs to receive the signal from the indoor temperature sensor and automatically shut down when the indoor temperature reaches the set temperature.
If this temperature sensor fails, the air conditioner thinks that the room temperature has not reached the set temperature and turns on the compressor to cool it all the time. (In addition, another possible consequence of a malfunctioning indoor temperature sensor is that the outdoor unit never starts – because it tells the air conditioner that the indoor temperature has reached the user's set temperature.) The temperature sensor is faulty and does not affect the air conditioner refrigeration.
So when the air conditioner is not down and it's getting colder and colder, you have to start to wonder about the temperature sensor. 2.Problems in the refrigeration system Air conditioning refrigeration requires a complete set of systems, and any problem in any link will lead to the decline or even disappearance of the air conditioning refrigeration capacity.
When the air conditioner loses its cooling capacity, the indoor temperature will never reach the set temperature. The air conditioner does not receive the signal of "the temperature is low enough" from the temperature sensor, so it will naturally not shut down. When the air conditioner does not stop and the indoor temperature does not drop, it is time to start to suspect the problem of the refrigeration system, and I hope it can help you.
Chunlan air conditioner refrigeration is normal, but it does not stop. Is it a fault of the internal temperature sensing head?
I'm waiting for you.
Chunlan air conditioner refrigeration is normal, but it does not stop. Is it a fault of the internal temperature sensing head? Hello dear, 1
There are many temperature sensors that need to be used on the air conditioner, among which the indoor temperature sensor is related to "shutdown", which is installed on the air conditioner. The air conditioner needs to receive the signal from the indoor temperature sensor and automatically shut down when the indoor temperature reaches the set temperature. If this temperature sensor fails, the air conditioner thinks that the room temperature has not reached the set temperature and turns on the compressor to cool it all the time.
(In addition, another possible consequence of a malfunctioning indoor temperature sensor is that the outdoor unit never starts – because it tells the air conditioner that the indoor temperature has reached the user's set temperature.) The temperature sensor is faulty and does not affect the air conditioner refrigeration. So when the air conditioner is not down and it's getting colder and colder, you have to start to wonder about the temperature sensor.
2.Problems in the refrigeration system Air conditioning refrigeration requires a complete set of systems, and any problem in any link will lead to the decline or even disappearance of the air conditioning refrigeration capacity. When the air conditioner loses its cooling capacity, the indoor temperature will never reach the set temperature.
The air conditioner does not receive the signal of "the temperature is low enough" from the temperature sensor, so it will naturally not shut down. When the air conditioner does not stop and the indoor temperature does not drop, it is time to start to suspect the problem of the refrigeration system, and I hope it can help you.
There is no compressor in the sterilizer, because it does not have a refrigeration function, so there is no need to install a compressor.
There are many reasons why the air conditioner can't be turned on: the first remote control reason: 1. The screen is garbled or frozen. >>>More
Air conditioner new off the assembly line compressor: dismantle the old and refurbished machine. >>>More
Compressor**.
First, the replacement cost of the original compressor belt is about 1200 yuan to 1500 yuan (compressor, replacement cost, vacuum + refrigerant cost), and the second is the replacement cost of the new compressor of the shop repair shop is about 1000 yuan, and there is a second-hand compressor replacement of about 700 yuan. (**** on the Internet, for reference only). >>>More
Haier air conditioning. The core components of the compressor are international famous brand compressors, Mitsubishi, Panasonic, Hitachi. >>>More