Ask for the installation method of connecting radiators to the cooking and heating dual purpose stov

Updated on home 2024-05-12
15 answers
  1. Anonymous users2024-02-10

    Cooking stove + radiator heating system, generally natural circulation, its installation method: the lowest position of the heating furnace, the center height of the radiator is at least 50cm higher than the center height of the heating stove, and the uphill installation is.

  2. Anonymous users2024-02-09

    The installation method is as follows:

    1. First of all, when you open the package, you will find that there will be two hooks behind the water heater, which are hung on the wall.

    2. After seeing the hook, measure the distance between them up and down, and then measure the length and width of the water heater, and then draw the position on the wall that needs to be blinked.

    3. After the painting is done, start to make eyes, basically speaking, some of the water heaters are with expansion screws, if not, you need to buy them, it is best to buy a larger one, which will be more robust, and the expansion screw head of the water heater is with a hook, don't buy it wrong.

    4. After punching the eye, use a hammer to knock the expansion screw in, and knock it in whole, so as to make the expansion screw more firm. Then use pliers or a wrench to tighten the expansion screw so that his head is up, so that the water heater can be hung up.

    5. Then lift the water heater, the barrel water heater is relatively heavy, it is basically recommended that two people lift it, so that it is convenient to hang, and then align the hook behind the water heater with the expansion screw and hang it up, so that the water heater is fixed.

    6. After the water heater is fixed, the next step is to connect the inlet and outlet water. Here you need to buy a 40-wide hose, then connect it to the water inlet of the water heater from the water outlet of your own home, and then connect the water outlet of the water heater to the water inlet of your own house, and then plug it into the power supply for heating.

  3. Anonymous users2024-02-08

    The water is coming out from above, the water is returning from the bottom, and the remaining openings are blocked, and the radiators are higher than the other, and the pieces near the stove are lower and gradually higher.

  4. Anonymous users2024-02-07

    I suggest that you find a plumbing master to help you adjust it, whether it is hot or not at the bottom must be a problem with the water circulation, and the water inlet backwater indicates that the heat of the water is enough.

  5. Anonymous users2024-02-06

    1. The natural circulation installation pipeline should have a certain slope, the radiator and the boiler should have a certain height difference, generally more than meters, the diameter of the pipeline should be DN-25 and DN--40, and the farthest end should not exceed 15 meters. Heating is achieved entirely by natural circulation.

    2. On the basis of the installation of natural circulation, a heating circulating pump is installed at the outlet of the water supply pipeline.

    3. The automatic pump circulates the radiator to replace it with a geothermal pipe, and the radiator can be completely placed on the ground. There is a certain height difference between the use and the heating stove, the installation is convenient and fast, the heating effect is remarkable, and the beauty is beautiful, but it cannot be used when the power is out.

  6. Anonymous users2024-02-05

    1. Installation location: It is forbidden to install in the following rooms: toilet, living room, bedroom, bathroom.

    2. Who installs, who after-sales. Therefore, it is recommended to install it by the first wall-hung furnace store.

    3. The installation is more complicated than other household equipment, because there are 5 pipelines, and it involves the transformation of natural gas pipelines, involving many accessories, the pressure should be appropriate, the air tightness should be good, and the boiler should be debugged after installation.

    Most people can't do that.

  7. Anonymous users2024-02-04

    The number of radiators to install should be determined jointly according to the size of the stove and the size of the house, for example, 3 cast iron 60 radiators should be installed in a house of 15 square meters.

  8. Anonymous users2024-02-03

    Merchants who sell heating stoves generally help users design and install radiators.

    If the merchant won't, you can buy another one. Otherwise, it is estimated that they will not be able to do it after sale.

  9. Anonymous users2024-02-02

    The radiator and the boiler should have a certain height difference, generally more than meters, the diameter of the pipe is DN-25 and DN--40, and the farthest end is not more than 15 meters.

    Confirm the integrity of the radiator packaging before installation, adopt corresponding shockproof and anti-collision measures when placed, and the radiator cannot be dragged in any way, and the radiator should be stored in a dry and rainproof safe place. The site should be cleaned up, and the valves, main pipes, branch pipes and pipe branches and hangers of the heating system have been installed and the pipeline flushing and pressure test has been completed according to the design requirements.

  10. Anonymous users2024-02-01

    You can install radiators, but you have to pay attention to the setting of the pipeline, you must be a professional and skilled veteran to install it, regardless of the road circulation is not good, it will affect the circulation of water, easy to hold air, resulting in the radiator is not hot, and a certain slope is required.

  11. Anonymous users2024-01-31

    Single-pipe tandem type: Single-pipe indoor heating systems cannot regulate the flow rate of each radiator individually, and this connection method should be avoided as much as possible in practice.

    1. The first thing to do before the installation of the radiator is to carry out on-site measurement and design to determine the model, number of pieces, water inlet and outlet mode and specific installation location of the radiator, so as to be able to select the appropriate radiator product according to the actual situation.

    2. Slotting the ground or wall, in order to bury the exposed pipeline, the construction team must groove on the wall and the ground, the depth or width of the groove, lay the pipeline and protect the card groove according to the position of the early heat sink positioning slotted to lay the branch pipe, lay the steel groove in the branch pipe to protect the pipeline, and the system is closed for water injection and pressure.

    Groove the floor or wall. In order to bury the exposed pipelines, the construction team must make grooves in the walls and ground, and the depth or width of the groove requires special installers to gather and actually deal with it.

    Lay the tubing and guard the card slots. According to the position of the heat sink positioning in the early stage, the branch pipe is slotted, and the steel channel can be laid in the branch pipe according to customer needs to protect the pipeline, and the system is closed for water injection and pressure.

    Install the water collector and manifold. The water distribution and collection device is a water flow distribution and collection device composed of a water divider and a water collector. The installation of the water separator should be kept level, and it should be wiped clean after installation.

  12. Anonymous users2024-01-30

    1. Many bungalows can be equipped with gravity circulating heating, because the height of the boiler used is very small, and the center of the boiler must be lower than the center line of the radiator, so that it can basically be circulated, but the gravity pressure head is smaller.

    It is good to decorate the small room of the square meter with more radiators, the model does not have too many requirements, the general radiators will be on the line, and the radiators will definitely not be installed at the height of the beams, and the upper part of the radiators will not exceed the height of the window sill board.

    Boiler heating is available in the northern region, and of course, there are also boiler heating in some southern regions.

    A large number of people may feel that they should pay attention to the purchase of boiler heating radiators, but when they buy them and install them at home, they will no longer do other management, maintenance, and pay attention to them.

    First: Pay attention when installing boiler heating.

    Maintenance should be taken into account when installing radiators, and the opening area should be such that the whole group of radiators can be disassembled and lifted. And the decorative parts should be movable, when there is a problem with the radiator, it can be easily lifted out, revealing the entire pipe and gas sheet. There should be space for dismantling and replacing valves at the openings of risers and branch valves.

    Second: pay attention to the discharge of boiler radiator cohesion.

    Due to the water circulation stagnation caused by the condensation of gas in the heating pipe, which affects the heating, in addition to setting the exhaust valve on the top floor, the tail of each group of radiators is installed with a manual air release valve, and the action should be small when deflating, so as to prevent it from being broken, adjust the angle of the exhaust hole, prevent the heating water from polluting the wall, and tighten the air valve in time when the gas and water are mixed.

    Third: know the temperature requirements of the boiler heating room.

    The indoor temperature should be controlled at no less than 18 degrees during winter heating, and the average indoor temperature should reach 16 degrees, but for the elderly and children, the standard of 16 degrees is relatively low, but it should not be too high, too high will make people feel uncomfortable, and the temperature difference between indoor and outdoor is too large to easily cause colds and other diseases.

    Fourth: Pay attention to the leakage treatment of boiler radiators.

    If there is a water leak at the connection of the pipe fittings during the heating period, no matter the size can not be solved by itself, the professional maintenance personnel should be notified in time, and the leakage point should be repaired after depressurization, and then the maintenance must not be maintained with pressure, which will expand the leakage point and damage the pipe fittings.

    Fifth: Find out why the boiler radiator is not hot.

    The whole is not hot, and the outdoor water inlet and return valves may not be opened. The local heat of a single household may be caused by the fact that the top floor is not deflated. The radiator is half hot and half cool, which is caused by the accumulation of air at the tail.

    In short, in order to ensure the circulating pressure and temperature, the main reason for not being hot is air blockage, which can be solved by degassing.

  13. Anonymous users2024-01-29

    For naturally circulating heating, the circulation power depends on the difference between the gravity of the return water and the relative height difference of the supply and return water. The figure shows that after the heating system series line up and down the bend, the height difference of the water supply and return lines has been very small, (80 cm radiator height and then subtract the height from the ground) if the horizontal line is long, it may not be able to circulate.

  14. Anonymous users2024-01-28

    If the system has been completed, it is necessary to add a circulating pump, otherwise it cannot be used normally. It is okay to lower the position of the boiler by 1 meter or raise the position of the radiator by 1 meter.

  15. Anonymous users2024-01-27

    Radiators are different from other commodities, choose a good radiator, after buying back the radiator installation is also very important, the quality of radiator installation will not only affect the normal use of radiators, but also affect the experience of indoor heating, if there is a problem with the installation of radiators, it will directly lead to water leakage and many other problems, and even cause property losses to the owners, in this regard.

    Shanghai Darui radiator.

    Let me introduce you to the radiator installation process.

    The first step: first with the radiator seller's technical personnel together with the field measurement design, to determine the radiator model, the number of pieces, the way of water inlet and outlet and the specific installation location, the technician according to the actual situation and communicate with the owner, determine the radiator model, the number of groups, the number of pieces per group and the installation location, etc., and sign the radiator purchase and sale contract with the seller.

    Step 2: Sign a construction agreement with the radiator construction unit to ensure the quality and risk of construction, and the general construction unit should indicate on the construction agreement that the construction of the heating system should be guaranteed for at least one heating season. It is best if the radiator sales unit and the construction unit are the same unit.

    Step 3: Construction of the first phase of radiator installation. The installation of the radiator is a two-step process:

    Phase I and Phase II. The first phase of the heating project includes the positioning, slotting, pipe routing (or pipe modification), pipe connection (welded pipe), installation of water collector and distributor, pressure test, etc.; The second phase of the project includes: the installation of radiators (fixed suspension of radiators, the connection of valves with radiators and heating pipes), the pressurization detection of the whole system and the commissioning of radiators.

    Step 4: Construction of the second phase of the radiator installation. After the decoration work of the customer's home has been carried out until the wall has been painted or the wallpaper has been pasted, the second phase of the project construction, the installation of the radiator, the installation and the pressure test are qualified, and the installation of the wooden floor can be carried out.

Related questions
9 answers2024-05-12

I think the sea blue of the butterfly makeup is not bad.

Concealing has the smell of nude makeup. >>>More

16 answers2024-05-12

As mentioned upstairs, most of the factors for makeup removal are not doing a good job of moisturizing before makeup, but as far as the powder is concerned, the reason for the powder is greater than the moisturizing factor. >>>More

11 answers2024-05-12

Price. The price of the hybrid car is relatively high, with the same configuration, the ** of the hybrid car may be at least 5w higher, how much can you buy with excess oil in 5w? The average consumer thinks that it is not cost-effective. >>>More

9 answers2024-05-12

When summer comes, it is easy to cause unnecessary damage if you don't pay attention to sun protection, so in addition to the necessary sunscreen, you also need a sunny umbrella that can protect against ultraviolet rays. What brand of umbrella is good? What are the brands of umbrellas? >>>More

7 answers2024-05-12

It depends on the occasion and environment in which you use it. >>>More