1) Do not apply transverse load on the piston rod of Wuxi Smart cylinder, and the special ratio is when the stroke is long. If there is a transverse load, a guide rail should be set to bear, 2) the relief valve body of the cylinder diameter 20 40 can be rotated in the range of 360 °, so the adjusting screw of the relief valve can be set in any direction. The rotation method is to confirm that there is no residual pressure in the cylinder, then release the cylinder mounting parts (such as foot seats, flanges), press the relief valve body, tighten the set screw, and the relief valve body can be rotated.
Push the pressure plate on the relief valve body and tighten the set screw at the same time, and the relief valve body cannot be rotated.
3) When the cylinder is installed, it is necessary to confirm that the relief valve body does not rotate, otherwise the buffer may fail. For the cylinder of 20 40, when installing the cylinder mounting, the set screw of the relief valve body should be loosened and then carried out, and the set screw should be tightened after installation.
4) The maximum number of rotations of the adjusting screw of the relief valve, 6 circles for the cylinder diameter 20 50, 10 circles for 63 100, clockwise rotation for the direction of closure, from fully closed to fully open, it is strictly forbidden to exceed the maximum number of rotational turns.
5) The motorcycle cylinder port is designed according to the highest cylinder degree of 3m s. If the cylinder stroke is short, the effective cross-sectional area of the charging and exhaust circuit is not large enough, and the desired cylinder speed may not be achieved.
-
Hello, don't drive over the speed limit, don't operate savagely.
-
The standard cylinder is suitable for all walks of life, and is specially used for the cylinder on the dust removal equipment, which is generally equipped with poppet valve and electromagnetic pulse valve, and can also be customized according to the specific requirements and needs of customers.
The following precautions should be paid to the installation and adaptation of standard cylinders:
1. When the load changes during work, a cylinder with sufficient output force should be selected;
2. Under high temperature or corrosive conditions, the corresponding high temperature resistant or corrosive cylinder should be selected;
3. In the case of high humidity, dust, or water droplets and welding slag, the cylinder should adopt embarrassing protective measures;
4. Before the cylinder is connected to the pipeline, the stolen goods in the pipeline must be clear to prevent sundries from entering the cylinder;
5. The medium used in the cylinder should be filtered by the filter element of more than 40um before it can be used;
6. In the low temperature environment, anti-freezing measures should be taken to prevent the moisture in the system from freezing;
7. The cylinder should be tested for no-load operation before use, and the buffer should be adjusted to the minimum i before operation, and gradually abandoned, so as not to damage the cylinder;
8. The cylinder should avoid lateral load as much as possible during the working process, so as to maintain the normal operation of the cylinder and prolong the service life;
9. The cylinder is not suitable for removing for a long time, pay attention to the surface rust prevention, and the intake and exhaust ports should prevent blocking the cap.
The standard cylinder is suitable for all walks of life, and is specially used for the cylinder on the dust removal equipment is generally equipped with poppet valve and electromagnetic pulse valve, and the cylinder with different cylinder diameters and strokes is customized according to the specific requirements and needs of customers, the cylinder flange, the single ear and double ear of the cylinder, as well as the standard cylinder rod and the cylinder extended cylinder rod. The compressed air enters the air source treatment element, and after water filtration, decompression, and lubricating oil treatment, the dry, clean and lubricated air with a certain pressure enters the cylinder by the solenoid valve. The solenoid valve receives the signal of the electric control cabinet and controls the action of the cylinder to realize the automatic processes such as cold air, ash discharge, offline ash cleaning and air conversion.
Standard cylinders can be divided into specifications. Normal working conditions of the cylinder:
The medium and ambient temperature are -5 70, and the working pressure is the cylinder movement speed range of 50 500mm sSolenoid valve K25JD to 25 series two-position five-way globe directional valve can be divided into five two-position five-port three-position series specifications, according to the engineering requirements to choose the appropriate diameter, voltage, pipe thread, installation form of solenoid valve. It can also be selected according to the actual use.
There are two types of tire classes, one is the speed class and the other is the load class. The speed rating indicates the maximum speed at which the tire can carry a specified load under specified conditions. The load class is a number that corresponds to the maximum load capacity.
Heat transfer oil is widely used as a heat transfer medium for industrial oil, and the following will take you to understand the protection matters in the use process of heat transfer oil. >>>More
1. The rafting period is from April to October every year, and the rafting activity period in the central region is slightly shorter than that in the southern region, and changes with weather and hydrological conditions; >>>More
Precautions for the use of pulverizer:
1. Check whether there are foreign objects in the crushed cavity, and then turn on the power supply after emptying. >>>More
What do you mean by Shenma? I don't understand.