Construction site fire safety inspection records

Updated on society 2024-05-24
11 answers
  1. Anonymous users2024-02-11

    Write it once before the regular meeting, basically once a week, and the content can be as long as it is about firefighting, and if you really can't find it, there are also it in it.

  2. Anonymous users2024-02-10

    Legal analysis: 1. The establishment of the fire prevention institution of the project, the establishment and implementation of the fire prevention responsibility system and the fire prevention system;

    2. Whether to carry out fire safety training for all employees and popularize fire safety knowledge;

    3. Whether the implementation of the classified storage and custody system of flammable and explosive materials on the construction site, and the safety distance from the hot point and temporary power facilities meet the requirements; whether the warning signs are complete;

    4. Temporary living areas, office areas, warehouses, construction sites are equipped with fire extinguishing equipment and regular inspection system implementation;

    5. Whether the selection of temporary power load switch and load cable in the living and office area has been calculated and whether the load current of each circuit has been tested and adjusted to ensure three-phase balance; whether electrical appliances that are prone to fire are used in violation of regulations; The power outage system is enforced; whether there is a fire hazard in indoor electrical appliances;

    6. Whether the fire and electricity used in the office area and living canteen at the construction site are declared in accordance with the system and whether the use is standardized;

    7. Whether the fire protection measures in the fixed fire area are complete, and whether the safety distance meets the requirements of the specification; Whether the safety measures for temporary hot work are complete.

    Legal basis: "Technical Specifications for Fire Safety at the Construction Site of Construction Projects" During the construction process, the person in charge of fire safety at the construction site shall regularly organize fire safety management personnel to inspect the fire safety at the construction site. The fire safety inspection should include the following main contents:

    1. Whether the management of combustibles and flammable and explosive dangerous goods is implemented.

    2. Whether the fire prevention measures for hot work have been implemented.

    3. Whether there are illegal operations in the use of fire, electricity and gas, and whether the operating procedures for electric and gas welding and thermal insulation and waterproof construction are implemented.

    4. Whether the temporary fire-fighting facilities are in good condition and effective.

    5. Whether the temporary fire lanes and temporary evacuation facilities are unblocked.

  3. Anonymous users2024-02-09

    Hello dear dear, I am happy to serve you: how to fill in the fire safety inspection record inspection situation is normal, the fire equipment is normal, the lighting circuit is normal, the charging line is not abnormal, and the personnel are on duty normally, which is the fire safety inspection record of the fire record, and the content of the practice includes ten aspects: 1

    Whether there is any violation of rules and regulations in the use of fire and electricity2Whether the evacuation channel of the safety exit is unblocked3Safety evacuation indication indicates whether the car is in good condition 4

    Whether the emergency lighting fixtures are in good condition 5Whether the hydrant is in normal condition6Whether the fire safety sign is in good condition 7

    Whether the fire-fighting facilities and equipment are in good condition 8The situation of the personnel on duty in the key parts of the fire protection 9Inspector's signature 10

    Inspection situation "fire safety inspection record form" (hereinafter referred to as the "record form") is one of the most basic fire safety inspection work of key fire safety units, is the unit to carry out fire safety inspections, to ensure that the unit eliminates fire hazards, to prevent the occurrence of fire records, it is also to inspect the fire inspection personnel work performance of the internal record of the unit. The "record form" is filled in by the fire prevention inspectors of the grass-roots unit team each shift, carefully inspects and records the parts and facilities listed in the "record form", and records the departments, parts, time and problems found in the inspection, as well as the results of the treatment, so that the person in charge of fire protection can understand the current situation of fire safety in the unit in a timely manner, distinguish responsibilities and make countermeasures. The "Record Form" shall be signed by the fire prevention inspector and the person in charge of fire protection.

  4. Anonymous users2024-02-08

    1. The rectification of fire hazards and the implementation of preventive measures.

    2 Safe evacuation routes, evacuation signs, emergency lighting and safety exits.

    3. Fire truck passage and fire water source.

    4. Whether the fire-fighting facilities, equipment and fire safety signs are in place, complete and valid; Fire extinguishing equipment configuration and effective wishes.

    5. Whether there are any violations in the use of fire and electricity.

    6. The mastery of fire protection knowledge of key types of personnel and other employees.

    7. Personnel in key parts of fire safety are on duty and management wishes.

    8. The implementation of fire and explosion prevention measures for flammable and explosive dangerous goods and places, as well as the fire safety of other important materials.

    9. The daily inspection of the safety management department of each unit.

    10. Whether the normally closed fire door is closed, and whether the items stacked under the fire curtain affect the use.

    11. The setting of fire safety signs is in good condition and effective.

    12 Other contents that need to be reviewed.

  5. Anonymous users2024-02-07

    This is a checklist, just fill it out accurately.

  6. Anonymous users2024-02-06

    Just fill in the truthfully as above.

  7. Anonymous users2024-02-05

    Fire inspection records.

    Inspection requirements.

    1. Organs, organizations and institutions shall conduct fire prevention inspections at least once a quarter, and other units shall conduct fire prevention inspections at least once a month.

    2. The content of the inspection shall include:

    1. The rectification of fire hazards and the implementation of preventive measures.

    2 Safe evacuation routes, evacuation signs, emergency lighting and safety exits.

    3. Fire truck passage and fire water source.

    4. Configuration and effectiveness of fire extinguishing equipment;

    5. Whether there are any violations in the use of fire and electricity;

    6. The mastery of fire protection knowledge of key types of workers and other employees;

    7. Management of key parts of fire safety;

    8. The implementation of fire and explosion-proof measures for dangerous goods and places that are prone to explosives and the fire safety of other important materials;

    9. Fire (control room) duty and facility operation and recording;

    10. Fire prevention inspection;

    11. The setting of fire safety signs, intact and effective conditions;

    12. Other contents that need to be checked.

    3. The inspectors and the person in charge of the inspected department shall sign the inspection record.

  8. Anonymous users2024-02-04

    1. After entering the site, check whether there is a safety officer at the construction site.

    Second, whether the construction personnel enter the construction site after fire training (such as: the use of fire-fighting equipment) Third, whether the construction site is equipped with sufficient fire-fighting equipment.

    Fourth, you must wear a safety helmet when entering the construction site.

    5. Check the construction site for any violations of fire regulations.

    1. Randomly connecting temporary wires.

    2. There is no plug in the wire of the power tool.

    3. Whether there is smoking in the fire prohibition zone.

    4. Whether there are sundries blocking the fire-fighting facilities.

    5. Whether the use of open flame is approved by the leader.

    6. Whether the electric and gas welding personnel have an operation certificate.

    7. Whether the safety protection meets the safety standards.

  9. Anonymous users2024-02-03

    The content of the fire safety inspection can vary according to the nature of the unit and the seasonal dust cave regulations.

    According to the requirements of the purpose of the inspection, you can focus on the content of the eight aspects of the package in general:

    basic information of fire administration;

    Fire safety status of the production process.

    chaotic management of water and electricity;

    fire management status of key areas;

    general layout;

    the level of preparedness for fire extinguishing and evacuation;

    The degree of safety education and training for employees to grasp the characteristics of fire occurrence in the unit.

  10. Anonymous users2024-02-02

    The main internal prudent measures to fill in include: about the engineering aspect of Kuanxiang.

    1. Whether the fire-fighting equipment is damaged; 2. Whether there are flammable materials around the construction of electric welding and electroslag pressure welding; 3. Whether there is too much saw foam in the disc saw processing plant; Percolation.

    Fourth, in places where smoking is prohibited, whether there are workers violating labor discipline.

  11. Anonymous users2024-02-01

    1.The main problems of safety evacuation passages, evacuation indication signs, emergency lighting and safety exits: stacking debris in the safety evacuation passage, insufficient evacuation width, locked safety exits, no evacuation indication signs, failure of emergency lighting or insufficient illumination, etc.;

    Rectification measures: remove the debris piled up on the evacuation passage to ensure that the passage is unblocked; Open the locked safety exit door, or set up a fire emergency opening tool to ensure emergency escape; Set up evacuation indication signs and emergency lights in accordance with the national fire protection technical specifications, and carry out regular inspections to ensure that the facilities are intact and effective;

    2.The main problems of fire truck passage and fire water source: fire escape is encroached upon by parked cars, and fire trucks cannot pass; Large buildings do not have circular fire lanes; The water storage of the fire water source is insufficient, and the water supply facilities of the fire water source are faulty, and the fire fighting and rescue requirements cannot be guaranteed;

    Rectification measures: Set up clear signs to prohibit cars and other irrelevant items from encroaching on fire lanes, and punish units and individuals who illegally encroach on the passages; Set up fire lanes in accordance with the "Code for Fire Protection Design of Buildings"; Set up automatic water replenishment pipelines for fire water sources, and regularly inspect them to ensure that the water consumption for fire protection meets the requirements of national fire protection regulations;

Related questions
15 answers2024-05-24

Inspection and acceptance of steel bars: pay attention to the following points: 1. Check the number of steel bars and the diameter of steel bars against the drawings. >>>More

14 answers2024-05-24

There are fire safety training records, fire safety inspection records, fire safety drill records, fire safety activity records, etc.

7 answers2024-05-24

construction site. It is necessary to have a safety and fire prevention organization and safety. >>>More

13 answers2024-05-24

It can detect the construction area screen in real time, and actively trigger the alarm prompt when the monitoring area is not wearing a safety helmet, not wearing a safety belt, not wearing a uniform, sleeping on the post, smoke and flames, and the construction site safety management monitoring system is better to notify through text messages, **, alarm voice, etc.

5 answers2024-05-24

1. Inspection of electrical equipment, whether the electrical equipment meets the requirements of explosion-proof in some flammable and explosive places, and whether there is any random connection of wires in the workshop or workshop; >>>More