First, the water pipe in the machine is damaged. Second, the installation of the indoor unit is unqualified, and the pipe outlet is too high.
-
1. The drainage pipe falls off or is damaged, and there are dirt in it;
2. The installation is not level, and the snake pipe is prone to siphoning, and the water cannot be removed.
3. The water tray is displaced after handling and collision;
4. The water container is filled with water, and the outlet pipe is blocked by water (in fact, the outdoor atmospheric pressure presses the water in the pipe). Simply discard the water.
5. When the indoor air humidity is high, there is a layer of water beads on the air outlet frame, swing blade or connecting pipe surface of the indoor unit, which is a normal phenomenon.
-
The drain pipe of the internal machine is broken or falling off.
-
The indoor humidity is high, condensation, and it is good to change the air.
-
What should I do if the air conditioner leaks? What causes it It is summer now, and the use of air conditioners is more frequent, but in the process of use, we often encounter water leakage in the air conditioner. Water leakage in the air conditioner is a relatively common air conditioning failure, and the reasons for the water leakage in the air conditioner are also multifaceted.
Causes of water leakage in the air conditioner: 1. The air conditioner unit is offset, resulting in the drainage pipe not being flush or the nozzle is raised, making it difficult to discharge the water flow. Consumers need to recalibrate the position of the air conditioner with a normal level tester, and the drain pipe should be lowered if it is too high.
2. The drain pipe is bent, aged or blocked, which requires consumers to replace the drain pipe or clean the drain pipe regularly. 3. Condensation on the piping of the air conditioner requires consumers to check the tightness of the copper pipe and replace the aging tape regularly. 4. The heat exchanger drips, which usually requires consumers to clean up or add refrigerant, if the water still drips after cleaning and adding refrigerant, it proves that there is a problem with its tightness and needs to be repaired.
What to do if the air conditioner leaks: 1. Analysis and maintenance: The cause of the water leakage of the indoor unit is generally caused by the wrong installation position of the outlet pipe or the rupture of the outlet pipe.
Observe that the compressor refrigerates normally. When doing the drainage experiment, it was found that the left side of the indoor unit (water outlet pipe) was leaking. After peeling off the bandage at the leakage, the water outlet pipe was inspected, and it was found that there was a crack in the water outlet pipe at the mouth of the casing, which was estimated to be leaking due to the burr at the mouth of the casing when installing the water outlet pipe.
Maintenance result: File the burr at the mouth of the casing with a file, replace the new outlet pipe, and then power on the machine for troubleshooting. 2. If it is an ordinary dripping, it is normal, the indoor temperature is higher and the air containing more water vapor enters the air conditioner, after being cooled, the air temperature drops, the water vapor that can be contained is reduced, condensation appears, and water droplets are formed to drip down the drainage pipe.
The outdoor unit works in an air environment with high humidity, and a lot of frost forms when it is heated, and melts water when it is shut down to melt. The machine should be fine, I don't know which product, their staff should explain it clearly, and second, they should press a large water tray and then use a pipe to drain the water away.
-
If the air conditioner pipe leaks, condensation will occur if the insulation layer is damaged (especially at the joints and connections with the internal and external units), and condensation will occur. The condensate on the surface of the pipe has no drainage system, and can only fend for itself.
-
Hello, FYI, I hope to help you, this is normal. The copper pipe of the air conditioner is dripping, generally a low-pressure return pipe, which contains the gas returning from the evaporator, which is still evaporating before flowing back to the compressor, but the strength is low, and the surrounding air humidity can condense and drip water.
If the dripping copper pipe of the air conditioner is not particularly serious, it is generally normal. Solution: Do a good job of thermal insulation of the copper pipe of the air conditioner, and avoid the gas in it from contacting the air, then the problem of dripping water in the copper pipe of the air conditioner can be completely solved.
The specific solution is to turn off the power of the air conditioner, and then wrap the fabric or clothing that can play a warm effect on the air conditioner compressor and the copper pipe of the air conditioner, if after this operation, water seeps out of the copper pipe or freezes in the package, then the air conditioner should be fluoridated.
Can I still help you?
-
It may be that the water tray of the air conditioner is blocked, the drainage pipe is blocked, and you need to clean up the dirt and foreign objects inside; It may also be that the drain pipe is installed at the wrong angle and the garbage accumulates inside, so be sure to clean it up. 1. First of all, we must confirm whether the refrigeration state is not good, the refrigeration state is not good, it will not drain, if the refrigeration is normal, it may be that the drainage pipe is blocked, and the indoor machine will leak after a long time, because the indoor unit has a water tank, which is not full and normal, and it will overflow if it is more, of course, you must also clearly say whether the drainage is so when it is installed or recently, if it is newly installed, it may not be clogged with dirt, maybe the drainage pipe is not installed. 2. The internal machine is not properly installed, usually the internal machine should be installed horizontally or tilted towards the condensate drain outlet.
If it is tilted in the opposite direction, it will cause the condensate to overflow and drip, which can be solved by adjusting the tilt angle. 3. The condensate pipe is blocked, resulting in overflow due to the inability of condensate to be discharged, and the phenomenon of dripping water can be solved. 4. Fan failure or filter blockage, resulting in cold energy can not be taken away, resulting in evaporator condensation (or even freezing), this situation is usually the air volume of the inner machine is small, if it is a filter problem, you can try to clean the filter screen, if it is a fan problem, you need to find a professional for maintenance.
-
It must be blocked, but there is a blockage that needs to be checked, and tell you a simple and practical inspection method 1, open the inner machine panel, see if the filter is blocked, and the filter will affect the drainage.
2.If not, there is a foreign body in the drain, and you can clean it with a curved wire. Summary of solutions to the causes of water leakage in the indoor unit of the air conditioner:
The installation of the wall-mounted inner unit is not level, and the common reason is that the inner unit is low on the left and high on the right. Solution: Readjust the angle of the fixed wall panel horizontally.
The wall-mounted indoor unit connecting pipe is low inside and high outside;
Solution: Re-punch (or reaming and trimming) to adjust the angle of the wall hole to achieve the inner height and outer low. The position of the drain outlet of the wall-mounted indoor unit is lower than the position of the wall hole, resulting in the condensate not flowing out. Solution: Increase the height of the wallboard.
-
Will you deal with water leakage in the air conditioner? Learn a trick from the air conditioner master, do it yourself and solve the cause of water leakage in the air conditioner in minutes, what to do if the air conditioner leaks, how to solve the water leakage of the air conditioner, how to solve the problem of water leakage in the air conditioner, and the water leakage of the air conditioner.
-
Probably, it's really possible that the drain line is clogged.
-
If your air conditioner is new, it's mostly a matter of installation. If it is not newly installed, it is mostly caused by the leakage of refrigerant, and the refrigerant needs to be replenished. A refrigeration senior mechanic!
The reason why the indoor unit will leak water is due to the following situations: 1Improper installation of the airframe:
The indoor unit is tilted, and the direction of the pipe intersection is too high. 2.Bad drains:
Poor drainage occurs due to the drain being loose or bent into a wavy shape. 3.Condensation on piping:
Because the insulation material on the pipe is too poor or too thin, when the refrigerant in the pipe passes through, it causes condensation. 4.Heat exchanger dripping:
1) The heat exchanger is full of dust and causes the temperature of heat exchange to be uneven, and water droplets are generated in the middle of the heat exchanger, and the water droplets falling outside the water tray will drip into the room. 2) The lack of refrigerant in the air-conditioning system causes the indoor unit to freeze, and the water droplets formed by the melting of the ice do not drip directly into the water tray. When there is a leakage of the indoor unit, you can carry out self-inspection according to the above situations, if you can deal with it yourself, it is better, if you can't solve it yourself, you should ask professional and technical personnel to come to the door in time to deal with it.
a.It is possible that the drain is clogged and excess water is spilling out of the chassis; b.The inside plane of the air conditioner chassis is equal to or lower than the outside plane, so condensate overflows from the inside of the chassis c
Water leakage caused by chassis corrosion, desoldering, welding defects at screw holes, etc. Very normal. That place is where the cryogenic refrigerant circulates, and the water vapor in the air condenses into water when it hits a cryogenic object.
The principle is the same as that of indoor condensate generation. You don't want it to drip water, just wrap it in insulation or something. The water should drip out at the outlet pipe of the external machine, but because the installation of the water pipe is uneven, so that the water flows to the house along the fan blades and the air outlet of the internal machine, you had better find a professional installer and let them help you raise the water pipe, but you don't move it yourself.
Your air conditioner is fine. Causes of water leakage: Problems in installation and use can cause water leakage in the air conditioner.
In terms of installation, the installation of inclined air conditioners, which means that the levelness is not qualified, will leak due to water accumulation. The wall hole punched during installation is too high, resulting in poor drainage of the drainage pipe, which makes the water tray of the indoor unit overflow with water, so that the indoor unit will also leak. Problems with the use that caused the water to leak:
The first is 'dirty blockage', that is, the dust that is not cleaned in time accumulates in the plastic pipes, resulting in poor drainage. The second is that the drain pipe is moved or knotted. The third is that the drainage pipe that has been used for a long time is cracked due to the aging of the plastic.
In view of the cause of water leakage, in the installation of air conditioners, it is necessary to observe whether the machine is slippery and whether the wall hole is higher than the machine. During use, the filter should be cleaned frequently to avoid water leakage and improve refrigeration efficiency. Do not move or tie knots in the drain pipe.
There are different remedies for different causes of water leakage. If the drain pipe is broken, it can be replaced for a small fee. If it is 'dirty', clean the blocked section of the drain.
-
1. The cause of water leakage of the indoor unit of the air conditioner.
1.The filter is clogged.
The filter screen of the indoor unit of the air conditioner is used to filter dust and impurities in the air, if the filter is blocked, the condenser of the indoor unit of the air conditioner will be under pressure, which will cause the indoor unit of the air conditioner to leak.
2.Clogged drains.
The drain pipe of the indoor unit of the air conditioner is used to drain the water in the condenser, if the drain pipe is blocked, the water in the condenser will not be discharged, resulting in the leakage of the indoor unit of the air conditioner.
3.Leaking drains.
The drain pipe of the indoor unit of the air conditioner is used to drain the water in the condenser, if the drain pipe leaks, the water in the condenser will leak out, resulting in the leakage of the indoor unit of the air conditioner.
4.Drain pipe damage.
The drain pipe is used to drain the water in the condenser, if the drain pipe is damaged, the water in the condenser will leak out, resulting in the leakage of the air conditioner indoor unit.
Second, the solution to the leakage of the indoor unit of the air conditioner.
1.Clean the filter of the indoor unit of the air conditioner.
The reason is that the filter screen is blocked, you can remove the filter cavity and close the screen, clean it with clean water, and then put the filter back to its original place to quietly crack to prevent water leakage of the indoor unit of the air conditioner.
2.Clean the drain pipe of the indoor unit of the air conditioner.
The reason is that the drain pipe is clogged, you can remove the drain pipe, clean it with clean water, and then put the drain back to prevent the air conditioner indoor unit from leaking.
3.Replace the drain pipe of the indoor unit of the air conditioner.
If the cause of water leakage of the indoor unit of the air conditioner is leaking or damaged drain pipe, you can remove the drain pipe, replace the new drain pipe, and then put the drain pipe back to prevent the air conditioner indoor unit from leaking.
Conclusion: Water leakage of air conditioner indoor unit is a common problem, and its causes may be blocked filter screen of air conditioner indoor unit, blocked drain pipe of air conditioner indoor unit, leakage of drain pipe of air conditioner indoor unit, damage to drain pipe of air conditioner indoor unit, etc. The solutions to the water leakage of the indoor unit of the air conditioner include cleaning the filter screen of the indoor unit of the air conditioner, cleaning the drain pipe of the indoor unit of the air conditioner, and replacing the drain pipe of the indoor unit of the air conditioner.
Consumers should take effective measures to prevent water leakage in the indoor unit of the air conditioner according to the actual situation.
-
Long-term use of air conditioning will cause poor drain pipe causes due to the aging of the drain pipe loose or bent into a wave shape, the drain pipe is blocked or there are some leaks in the drainage pipe room, resulting in poor drainage, the indoor unit sink and the drain pipe are not tightly connected, the water can not be discharged, resulting in water flowing out from the air outlet plate of the inner room machine, generally within half an hour after opening will begin to leak from the air outlet of the inner machine, this problem is not big, as long as the pipeline is dredged or replaced with a new drain pipe.
Condensation on the pipeline, due to the poor quality or too thin insulation material on the pipeline, or not completely wrapped, when the refrigerant in the pipe passes, it causes condensation; The drain pipe leading out of the exterior is artificially blocked or the drain is blocked by stolen goods, so that the condensation cannot be discharged.
If there is a leakage of the indoor unit, you can carry out self-inspection according to the above situations, if the horizontal position of the indoor unit is displaced, you should carefully check whether the position is displaced, whether the lead end of the pipeline is high, if the horizontal position deviation is too large, you should notify the Gree air conditioning maintenance service department in time to overhaul and adjust during the warranty period.
The former situation is less presented, the latter situation is usually the air conditioning installation workers are not dedicated, casual installation formation, if you have the ability to start, you can personally check and adjust it, do not accommodate.
If you don't lack calcium, don't make up for it, eat more fruits and vegetables
In fact, babies can eat tofu when they are six months old. Six-month-old babies have already erupted several teeth, and tofu is tender and smooth, so many babies are suitable for eating. Tofu is made from soybeans, so tofu contains phytoestrogens, which have certain benefits for the physical development of the little one and can make the little one grow faster. >>>More
Minimally invasive obstetrics and gynecology experts said: There are many young women who have unplanned pregnancies and do not want children will first think of having surgery to terminate the pregnancy, and due to the lack of knowledge, they often miss the best time. >>>More
First, the baby is well weaned for a few months.
Generally speaking, it is best for the baby to be weaned between the age of one and a half to 2 years old, because the baby's physical fitness is relatively good at this time, and the growth and development of all levels of the human body is relatively perfect, so this time after weaning is the best choice. Many parents are just weaned when the baby is one year old, but in fact, at this time the baby's digestive tract and human immune system have not completely grown and developed. >>>More
It is medically believed that prenatal education can begin after six months. However, in recent years, some people believe that the sooner prenatal education is carried out, the better, because for the fetus, he will have an intimate connection with the mother throughout the pregnancy process; At the beginning, if the pregnant woman can listen to some elegant ** and read some comfortable stories, it can relieve the mental pressure caused by pregnancy, which is very beneficial to the fetus.