Is the motor air water cooler related to the direction of rotation of the motor

Updated on Car 2024-06-20
5 answers
  1. Anonymous users2024-02-12

    1. The steering of the rotor of the motor is related to the current.

    Changing the direction of rotation of the rotor of the motor should be divided into two cases.

    1) For AC motors.

    For capacitive single-phase motors, to change the steering of this motor, it can be achieved by changing the position of the capacitor in series.

    Three-phase AC asynchronous motor, to change the steering of this motor, as long as any two of the three-phase symmetrical power supply in the three-phase stator winding can be adjusted.

    2) For DC motors.

    Just swap the two power cords of the motor. If it is an independent excitation motor, adjusting the polarity of the excitation power supply can also achieve the purpose of changing the direction of the rotor.

    2. Motor rotor: It is also a rotating part in the motor. The motor is composed of two parts, the rotor and the stator, which is used to realize the conversion of electrical energy and mechanical energy and mechanical energy and electrical energy. Motor rotors are divided into motor rotors and generator rotors.

    3. The motor rotor is divided into two types: the inner rotor rotation mode and the outer rotor rotation mode. The internal rotor rotates in such a way that the core in the middle of the motor is a rotating body, and the output torque (referring to the motor) or the income energy (referring to the generator). The external rotor rotation mode takes the outer body of the motor as the rotating body, and different ways facilitate the application of various occasions.

  2. Anonymous users2024-02-11

    Lianyungang is indeed better at producing sampling coolers, but you say that this is a leather bag company.

  3. Anonymous users2024-02-10

    (1) Solar energy received by the solar panel per minute:

    w= w/m2×6m2×60s=;

    2) Car Gravity:

    g=mg=600kg, the resistance of the car:

    f=, car traction:

    f=f=, the useful power of the electric motor converted into mechanical energy:

    p useful = fv =

    Total power of the motor:

    P total = UI = 120V 6A = 720W, the efficiency of the motor:

    p useful p total.

    294w720w

    A: (1) The solar energy received by the solar panel per minute is;

    2) The average resistance experienced by the car is; The efficiency with which an electric motor converts electrical energy into mechanical energy is.

  4. Anonymous users2024-02-09

    Electrical engineering mainly talks about the principles and applications of generators and motors. I haven't learned the basics of motors and drag, I have learned electric drag technology, mainly talking about the application of drag systems in power electronics.

  5. Anonymous users2024-02-08

    Dude, it's better to take a look at it yourself if you have this effort, this experiment is not difficult, and the answers to the later thinking questions can even be found in the electrician book and the electrician tutorial book. If it's not good, let's look for the classmates you did, because the experimental reports we did this experiment were all taken back by the school.

Related questions
7 answers2024-06-20

Reverse braking, of course, braking is the goal.

Forward and reverse is to change, and turning is the goal. >>>More

7 answers2024-06-20

The function of the motor protector is to give the motor a comprehensive protection control, in the motor overcurrent, undercurrent, phase failure, stalled, short circuit, overvoltage, undervoltage, leakage, three-phase unbalance, overheating, grounding, bearing wear, stator and rotor eccentricity, winding aging to alarm or protection control. >>>More

8 answers2024-06-20

Asynchronous motors. Induction motors) work by generating an induced current in the rotor through the rotating magnetic field of the stator. >>>More

10 answers2024-06-20

The current of the 55kw motor is between 110A, (calculated according to the empirical algorithm of two currents per kilowatt), choose CJ20-150 contactor, and choose according to the current of the load.

16 answers2024-06-20

380V three-phase asynchronous motor power 1KW power corresponds to 2A current, so the normal current of your motor should be 11A, 16A current corresponding power is 8KW, you can directly switch to the same speed) of the motor, the role of frequency conversion is mainly to solve the problem of soft start of the motor and lower the speed, and the power will be reduced while the speed is lowered, and it is impossible to solve the problem of small horse-drawn carts. >>>More