What does the refrigeration input power 1035 55 1420 mean?

Updated on Car 2024-06-04
13 answers
  1. Anonymous users2024-02-11

    This is an inverter air conditioner, which should be matched, suitable for a room of about 18 square meters.

    1035W is the rated input power of this air conditioner.

    55W is the minimum power.

    1420W is the maximum power, that is, the power input when the air conditioner is just turned on.

    Inverter air conditioner is under the control of inverter module, the compressor speed can be fast or slow, so the cooling capacity or heating capacity of the air conditioner can also be large or small, fast or slow, when the air conditioner is just turned on, the inverter air conditioning compressor is in a high-speed state, so the cooling capacity or heating capacity is very large, so that the indoor temperature quickly reaches the set temperature; When the room temperature reaches the set temperature, the compressor is in a low-speed operation state, and the cooling capacity or heating capacity is very small, and the power consumption is very small, so as to maintain the indoor temperature unchanged. Therefore, the cooling or heating speed of inverter air conditioner is fast, the indoor temperature difference is small, the comfort is good, and the long-term reasonable use can give full play to its power-saving characteristics. Inverter air conditioners are especially suitable for use in bedrooms or rooms with long power on periods of time.

    However, the structure of inverter air conditioners is relatively complex, so the manufacturing cost is high, and the installation must also be vacuumed, and the maintenance cost is also very high.

    The compressor speed of ordinary fixed-frequency air conditioner is always the same, so the cooling capacity or heating capacity is also the same, it is to maintain the indoor temperature within a certain range by controlling the start and stop of the compressor, so the indoor temperature difference is large and the comfort is poor. However, its structure is relatively simple, the manufacturing cost is low, and the maintenance cost is relatively small. It is especially suitable for rooms where the boot time is not very long, or the indoor temperature difference is not high.

  2. Anonymous users2024-02-10

    The meaning should be: the input rated power is 1035W, but because the air conditioning compressor works intermittently, the compressor running time is different according to the ambient temperature and the set temperature, etc., and the actual power may vary between 55 and 1420.

  3. Anonymous users2024-02-09

    According to the refrigeration power of 1060 (230-1450) W, you should be talking about the inverter air conditioner, when the indoor temperature is close to or equal to the set temperature, the air conditioner operates at a lower power (230W); When there is a large difference between the room temperature and the set temperature or when the power button is pressed, the air conditioner runs at a lower power (1450W).

    If the size of the inverter air conditioner is selected appropriately, it can ensure that the thermal balance is achieved during low-power operation, avoid repeated opening of the air conditioner, and keep the indoor temperature constant, so as to be comfortable and energy-saving.

  4. Anonymous users2024-02-08

    The air conditioner is rated for refrigeration power of 1060W, with a minimum input power of 230W and a maximum of 1450W. That is, the minimum power consumption per hour is kWh, and the maximum power consumption is kWh.

    Your air conditioner is an inverter air conditioner, just turn on or adjust the temperature difference, the compressor will run at high speed, at this time the power is the largest, the power consumption is also large, and when the indoor temperature reaches the set temperature, the compressor will automatically reduce the speed in the low power operation, at this time the power consumption is the smallest.

  5. Anonymous users2024-02-07

    What kind of air conditioner is in your home.

  6. Anonymous users2024-02-06

    The 125kW marked on the chiller refers to the unitThe power is 125kw。The conversion to cooling capacity is as follows:

    Calculation formula:1 HP for air-cooled units), 1 HP 3kW (for water-cooled units).

    The ammonia refrigeration unit belongs to the air-cooled unit, and its horsepower is:125kw/

    HP Profile

    "horsepower" is used as a power unit, expressed by hp (imperial horse) or (metric horse), also known as "horsepower", 1hp (imperial horse), 1 (metric horse) horse) is a power unit (generally refers to the input power) rather than a unit of cooling capacity, the national standard for refrigeration energy efficiency ratio is expressed by eer, cop refers to the energy efficiency ratio when heating, then cooling capacity = eer * power.

  7. Anonymous users2024-02-05

    Most of this happens with multi-online products.

    It will not appear on the one-to-one split air conditioner, and the power marked on the nameplate of this kind of product, whether it is an indoor unit or an outdoor unit, is the power of the whole machine.

    For multi-online, since there are many specifications of the indoor unit and many specifications of the outdoor unit, the matching of the internal and external units is not fixed, so the power of the outdoor unit is marked on the nameplate of the outdoor unit, and the power of the indoor unit is marked on the nameplate of the indoor unit.

  8. Anonymous users2024-02-04

    The rated refrigeration capacity refers to the refrigeration capacity generated by the air conditioner during normal refrigeration operation, and its unit is kcal, 1 horsepower.

    The cooling capacity is 2000 kcal, which should be multiplied to SI units, so that the cooling capacity of 1 hp is 2000 kcal

    2324 (W), where W (W) means cooling capacity, in particular, it should be noted that (W) here refers to.

    Cooling capacity, and electrical power (W) are two concepts that should not be confused. For example, the cooling capacity of an air conditioner is as follows:

    25000W (generally the cooling capacity is 2200 2600W are called one horse), but the rated electric power is average.

    It is 800 900W, and the cooling capacity of the air conditioner is 3500W (the general cooling capacity is 3200-3500W.

    are called horses), but the rated electric power is generally 1100W-1200W.

  9. Anonymous users2024-02-03

    The power consumption is related to the ambient temperature, as well as the room insulation, or the size of the space, the frequency of opening and closing the door, the amount of debris stacked, etc., the air conditioner can not be working all the time, the non-inverter air conditioner can be estimated in this way, when the air conditioner runs for more than half an hour (steady state), measure how much time the compressor works per hour, according to 1480w when working, and 150w when not working, you can basically get more accurate data. It can also be estimated that the air conditioner can run for more than half an hour, and the electricity degree can be estimated every hour, and the inverter air conditioner can also be calculated in the same way.

  10. Anonymous users2024-02-02

    It should be a big 1p, reason:

    1. In the actual sale of air conditioners, most of the input power is above 1000W, 2. Theoretically, 1P = ,, but also add about 100W of control power consumption, 3. Habitually, the air conditioning compressor is about (P), the power is (W), and the input power includes the compressor power and the power consumption of various mechanisms and circuits that control various actions of the air conditioner and perform actions (such as fans).

  11. Anonymous users2024-02-01

    It is impossible to tell whether it is an air conditioner based on the input power of the air conditioner alone.

    The number of horsepower of the air conditioner is calculated as 1 horsepower for every 2500W of the nominal cooling capacity of the air conditioner. It is customary in the industry to call the air conditioner with a nominal cooling capacity of 3500W as horsepower, and the nominal cooling capacity of 2500W and 2600W as 1 horse.

  12. Anonymous users2024-01-31

    930 (300-1310) W: The normal power in the refrigeration state is 930W, (300-1310) refers to the minimum power of 300W and the maximum power of 1310W after start-up.

    1120 (300-1430) + 750W: The normal power is 1120W in the heating state, and (300-1430) is the maximum and minimum value after starting. +750W is electric auxiliary heating (electric heating tube) with a power of 750W.

    Yours is an inverter air conditioner.

  13. Anonymous users2024-01-30

    In fact, due to the low temperature of the heating environment, the system pressure is also low, and the power is relatively small.

    However, due to the four-way valve of the outdoor unit in heating mode, the compressor heating belt, and the electric auxiliary heat start, it is normal for the power to be relatively high.

Related questions
21 answers2024-06-04

Yes, I'm a layman when I repair refrigeration. If you want to repair a freezer, how many TVs can be repaired, don't look at its high profits, it may not be cost-effective Eighth floor, I don't have to repair the refrigeration and don't necessarily lose it, because the cost of my coil is equal to the user's own refrigerator and freezer sold and then go to the second-hand door to buy a second-hand door of the same size. So most of the users don't fix it. >>>More

13 answers2024-06-04

degrees per hour according to the determination method is as follows: first, first judge the number of horsepower and refrigeration capacity of air conditioning 1 horse refers to the cooling capacity is roughly 2000 kcal, converted into international units should be multiplied, so the refrigeration capacity of 1 horse should be 2324 (w), where w (watt) represents the cooling capacity, then the horsepower should be 2000 kcal, and so on, according to this situation, then roughly can determine the number of horsepower and refrigeration capacity of air conditioning, under normal circumstances, 2200w-2600w can be called 1 horse, 3200w— 3600w can be called horse. Second, the power consumption mainly depends on the power of the compressor >>>More

5 answers2024-06-04

Input method stuck solution: In fact, it is also very simple, you can directly install another Chinese input method, for example, after installing the most commonly used Sogou input method here, of course, you can also install such as QQ Pinyin or other Chinese input. As shown in the figure below: >>>More

8 answers2024-06-04

Even if the air conditioner is turned on for refrigeration, the humidity of the room will not change much, because the moisture in the air conditioner will be discharged along with the water pipe. But why do you have to turn on your air conditioner at 16 degrees? 25 or 26 degrees is very comfortable, I open 27 degrees at night and cover the quilt, the remote control is the set room temperature, that is, how many degrees you adjust to the room will maintain how many degrees, but in the summer, the air conditioner almost can't hit 16 degrees, so not only power consumption but also air conditioning is easy to break. >>>More

7 answers2024-06-04

Reinstall the references.

Tenpay** ( >>>More