You go and ask your local Gree air conditioning department for after-sales service. I can also tell you that the indoor unit is leaking because the outlet pipe is blocked, running for a long time, bringing dirty things inside, clogging the sewer pipe, you find the outlet pipe, blow it inward, dredge the pipe, and everything is OK.
-
Look at the water leaking out of **, if it is from the air outlet, see if the drain pipe is unblocked. If it is condensation on the surface of the copper pipe or the condensation on the surface of the drainage pipe, the thickness of the insulation should be thickened, and the insulation thickness of the copper pipe is generally more than 15 mm, and the insulation of the condensate pipe is enough by 10 mm.
-
I bought Sany Heavy Industry is also the same crackling sound and leakage, just bought 10 days, the first day I found this phenomenon, Suning (Minhang Dongchuan) bought, manufacturers and sellers have come to see, all said that it is normal, after 2 people, others only saw the sound of the promise to disappear, the most bullish is Suning (Minhang Dongchuan) maintenance, visual inspection of the air conditioner, directly said normal, gone. Awesome.
-
Do you also have a section of drain pipe outside yourself, which refers to the section from the indoor unit drain pipe to the downpipe or floor drain? If there is a hose, check that the tube is sagging. I have encountered this situation, even if the drainage pipe is open, the drainage will not be smooth, it is recommended to replace the outdoor drainage pipe with a hard PVC pipe.
-
If you don't come for maintenance after a long time, I suggest calling 400 to complain to protect the legitimate rights and interests of consumers.
-
Water leakage in the Gree hang-up air conditioner can be caused by a variety of reasons:
1. Position offset of the air conditioner: If the position of the air conditioner is not slightly inclined to the direction of the water distribution pipe, the condensate generated will flow to the drainage pipe under the action of gravity, resulting in water leakage of the air conditioner. Workaround:
Re-measure the installation height of the air conditioner, and pay attention to appropriately lower the position of the air conditioner drain to ensure that the condensate can flow out smoothly through the drain pipe.
2. The drain pipe is blocked: the drain pipe is blocked by foreign objects or the drain pipe is blocked by twists and turns, and the condensate cannot be discharged normally, and can only flow out from the air outlet of the internal machine. Solution: Just clean or replace the drain every year.
3. Condensation in the piping: In addition to the evaporator and air outlet, this is another place where condensate will be generated. When the air conditioner is in operation, the temperature of the pipes used for the refrigerant is very low, and it is generally wrapped with an insulation layer to prevent condensation from developing.
However, if the insulation is damaged, condensation will appear on the pipes and drip directly from the pipes. Solution: Remove the old insulation layer and rewrap the pipe.
4. Damage to the drainage pipe: For example, the water distribution pipe is naturally aging and damaged, and it is damaged by rats, resulting in the leakage of the indoor unit of the air conditioner. Solution: Just replace the drain pipe.
5. The lack of fluorine in the compressor of the air conditioner outside the unit causes the internal unit to freeze, and the ice water is too much after the ice is not discharged smoothly, which will also cause the air conditioner indoor unit to leak, if this is the case, it is necessary to add fluoride to the air conditioner.
6. If the air conditioner lacks cleaning and maintenance for a long time, the internal machine is mossed, the drainage pipe is seriously dirty, and the air conditioner indoor unit leaks if the cold and heat exchange cannot be realized.
7. When the aluminum sheet of the air conditioner evaporator is deformed and touches the edge of the water tray, resulting in the water not flowing to the water tray or half of the water flowing to the water tray, the air conditioner indoor unit will also leak, but this kind of fault is more difficult to repair, so it is recommended to ask a professional manufacturer for after-sales treatment.
-
1.The drain is clogged. The most common cause of dripping water in an air conditioner's indoor unit is a problem with the drain pipe.
The deformation, relaxation, aging, and excessive bending of the water pipes lead to blockage, so that the condensate generated cannot be smoothly discharged outside, resulting in dripping water in the air conditioner. Solution: Unclog the drain.
2.The evaporator and filter screen of the indoor unit are not cleaned for a long time. Air conditioners are used frequently, and the interior is prone to dust accumulation.
If it is not cleaned up in time, a large amount of dust will accumulate inside, which will not only affect the cooling efficiency, but also cause the air conditioner to drip water. Solution: Clean the air conditioner.
In addition, regular cleaning of the air conditioner can not only solve the problem of dripping, but also greatly improve the cooling efficiency of the air conditioner and take care of respiratory health, which can be said to have many benefits. 3.The quality problems of the newly installed air conditioner or the quality problems of the indoor unit itself due to improper installation, such as damaged and improper fixing of the water tray, loose water outlet connecting pipe, incomplete packaging of pipe insulation materials, and inadequate horizontal installation of the indoor unit, will lead to dripping water of the indoor unit, which generally appears on the newly installed air conditioner.
Solution: Contact the maintenance personnel in time for maintenance.
-
1. The wall-mounted inner machine is not horizontal
The inner unit of the wall mount must be kept level, if one side is high and the other is low, it will cause water leakage. This is because there is a water storage box in the air conditioner to hold the condensate.
Although it is called a "water storage box", it is actually very shallow, like a plate. Fill the plate with water and tilt the plate at the same time – the water in the plate will definitely come out (the low one side will flow the water from). Moreover, the internal water pressure of the skewed water storage box is not enough, and the condensate cannot be discharged normally through the condenser pipe, and all of it flows into the room.
2. The installation height is not enough
The height of the water storage tray of the air conditioner shall not be lower than the height of the air conditioning hole. The condensate naturally flows out of the outdoor area by gravity, and the condensate pipe is higher than the water storage box, so the water naturally cannot flow out.
The water storage box of the air conditioner hangs up about 10cm away from the bottom of the unit. The water storage box of the air conditioner cabinet is about 35cm away from the bottom.
3. Condenser pipe problem
Common problems with condenser tubes are:
Broken condenser pipe - often occurs on old condenser pipes (especially when moving the machine, it may damage the old and brittle condenser pipe), at this time the water will not flow down the inner machine, but from the broken place of the pipe.
Condenser pipe fitting – Sometimes the condenser pipe is not long enough and needs to be connected to a section. Where two pipes are jointed, there is a risk of water leakage. The fault phenomenon is the same as the condenser tube breakage.
-
1. The solution when the installation is improper or the position of the internal machine is offset: because of the water leakage caused by improper installation, reinstall it. During installation, the installation position of the air conditioner needs to be re-measured, and the position of the air conditioner drain port needs to be appropriately lowered to ensure that the condensate of the air conditioner can flow out of the air conditioner smoothly through the drain pipe, and fix the fixed hanging plate of the indoor unit.
2. The solution to the blockage of the water pipe: you can first see whether the drain pipe mouth is blocked by the Huaiju book, and there is also a reason that the air conditioner is blocked due to too much dust inside, if the check is because of the blockage of the drain pipe, you can flush it through a high-lead macro pressure water gun or other tools to dredge it.
3. The solution to the quality problem of the drainage pipe: replace the drainage pipe with a new one!
4. Solution when the air conditioner heat exchanger drips: clean the filter regularly.
5. The solution to the quality problem of the air conditioner itself: if it is determined that it is a product problem, then it is necessary to contact the manufacturer as soon as possible to deal with it.
-
1. Cause 1 of air conditioner leakage: The air conditioner is not installed firmly when it is installed, and it is displaced after a long period of use, resulting in a change in the location of the drainage pipe and causing drainage difficulties. Workaround:
The indoor split is installed to a horizontal state, and the drain pipe mouth should be more than 10 cm lower than the indoor extension position. 2. Cause 2 of air conditioner leakage: quality problems of drainage pipes.
Some drainage pipes are of poor quality and are easy to age and relax, resulting in bent pipe shapes and poor drainage. Solution: Regularly inspect once every year or every quarter, and replace the drain pipe regularly.
3. Cause 3 of air conditioner leakage: condensation on the piping. Because the quality of the insulation material on the pipeline is too poor or too thin, when the refrigerant in the pipe passes through, it is easy to condense water.
Solution: Appropriately replenish the refrigerant (refrigerant) and replace the thickened copper pipe insulation material to avoid the phenomenon that the copper pipe is too long. 4. Reason 4 for air conditioner water leakage
The reason for the exchanger. The stolen goods of the filter screen are seriously not cleaned in time or the filter screen is damaged, which causes the evaporator to deform and make it unable to drip into the tank in time; The lack of freon in the air-conditioning system causes the evaporator of the indoor unit to freeze, and the water droplets cannot drip into the water-saving tray; The material of the air conditioner is not very good, the internal settings are not reasonable, the water cannot flow into the sink, and it stays along the plastic shell. Workaround:
Check that there is not enough or too much refrigerant master, and clean the filter (dust filter) evaporator. This answer applies to most air conditioner models from brands such as Gree.
1.The drain is clogged. The most common cause of dripping water in an air conditioner's indoor unit is a problem with the drain pipe. >>>More
Do you mean the remote control? A small hole on the back of the Gree air conditioner remote control, which says unlock and close, press it with a toothpick or something sharper, and then see if there is a "lock" sign on the display, if not, it means that the Gree air conditioner remote control of your home has been unlocked successfully; If there is still one, then after pressing it once, there should be no problem.
There are many reasons for the estimated thermal protection shutdown of the compressor, such as poor ventilation of the outdoor unit, low fan speed or blade deformation and fracture, abnormal pipeline pressure, etc. Should contact the seller or after-sales service in time for return or maintenance. >>>More
The minority obeys the majority. It's not very hot these days, so bear with it first, I really can't stand it and open it again.
There are many factors that the mobile phone cannot be turned on, and the battery, mobile phone software, and hardware will cause this kind of failure to turn on. We recommend trying the following: >>>More