It can be mixed, but it is suitable for large houses such as villas or duplexes, because the cost of installing floor heating in this kind of house will be very high, and mixed installation can be saved.
Usually, when the floor heating and radiator are installed at the same time, a set of premixed center device needs to be added, which is generally installed in the water collector, and the hot water produced by the wall-hung boiler at the same time has only one temperature, the operating temperature of the floor heating is below 60 degrees Celsius, and the operating temperature of the radiator is above 60 degrees Celsius.
-
First of all, the answer is yes; Secondly, floor heating and radiators are mixed, which is more suitable for large space heating such as duplexes or villas. Compared with pure radiators or pure floor heating, the operation of mixed heating will be more complicated, and the cost will naturally be higher. The main reason is that there is an extra set of pre-mixing center, the device is usually installed in the water collector, the reason for this is that the hot water produced by the boiler at the same time has only one temperature, the water temperature of the floor heating is low-temperature hot water, and the radiator needs high-temperature hot water, so it is necessary to install the pre-mixing center to make a part of the high-temperature hot water used in the radiator produced by the boiler become low-temperature hot water for the circulation of floor heating.
Examples of mixed heating are as follows:
1. Make radiators in bedrooms and floor heating in other public areas.
At home, we are generally nested on the sofa in the living room, and the floor heating is characterized by the gradual decrease in temperature from the bottom to the top, and we are more comfortable in such an environment; Installing radiators in the bedroom and turning them on when you go to bed at night is more energy-efficient and always good to spend less.
Second, the area with solid wood floor in the home is made into radiators, and other areas are made into floor heating. Solid wood flooring can not be installed floor heating, because the installation of solid wood floor heating needs to play keel, which causes a considerable section between the floor and the floor heating coil to be filled with air, and air is a poor conductor of heat, so that the room where the solid wood floor is installed has not been hot, and the other solid wood floor contains moisture, and it is easy to deform after being grilled for a long time.
From a practical point of view, it is generally not recommended to mix home heating, to put it bluntly, it is a bit overkill, and it is also true that it costs money. Home heating can be based on their own situation, choose floor heating or radiators, the main energy can be spent on the selection of heat sources, choose a quality wall-hung boiler, if the budget is generous, it is recommended to choose a foreign brand, such as Germany's Warlef, his wall-hung boiler rarely fails, use worry-free, of course, regular maintenance still has to do.
-
Yes, if the temperature at home is not enough, you can install radiators. Due to the relatively low temperature of the floor heating water, it is recommended to use steel for better thermal insulation.
-
Yes, like the general installation of floor heating users, in the bathroom are installed radiators, there is a special bathroom small back basket, Rubens heating hope to help you.
-
It can be mixed, and generally don't toss it so much at home.
-
It can be mixed, but due to the high water temperature of central heating, the floor heating valve should be opened as small as possible, or a water mixer can be installed to prevent the indoor temperature from being too high, which will bring hidden dangers to our health; Let's learn about other installation methods and characteristics of radiator installation at home:
1. Single-pipe series connection: this connection mode is to connect the water outlet of the first group of radiators and the water inlet of the second group of radiators, and the water outlet of the second group of radiators is connected with the third group of water inlets, and so on, this connection mode is mostly used in the traditional steam heating mode, the reason is that the steam temperature is too high, and it is easy to burn people, so this method is used to prevent the radiator temperature from being too high;
2. Parallel connection: It is the most used radiator installation method on the market, which is characterized by the water inlet pipe to a to, which is to directly connect the inlet and outlet of the radiator with the main pipeline, and the heating water flows out of the main pipeline directly after entering the first group of radiator inlets. By analogy, each group of radiators does not interfere with each other, but the distance of the flow path of the farthest group of radiators is also the farthest, and the water resistance is the largest, and the nearest water resistance of the first group of flow paths is the smallest, so the water resistance of each group of radiators is different, and the amount of water passing through is different, and the indoor temperature is uneven, so the adjustment of the temperature control valve is particularly important;
3. Parallel connection in the same journey: this connection method is that the inlet and outlet pipes are in opposite directions, for example, the water inlet of the first group of radiators is closest to the main pipeline, and the water outlet is indeed the farthest from the main pipeline; The specific connection method is that the water inlet of all radiators has not changed, and the water outlet of the nearest group of radiators does not return to the main pipe, but goes to the water outlet of each two groups of radiators, and then goes to the third group of radiator outlets, and goes to the farthest group of radiator outlets and then enters the main pipeline, so that the water flow distance of each group of radiators is the same, there will be no difference in water flow, and the temperature is well controlled, which is the most ideal connection method, but it is a bit expensive to pipe;
4. Octopus type: this connection method is generally not used for radiators, too much waste of pipes, brings great inconvenience to the construction, and is mostly used for the laying of floor heating pipes, it mainly adopts the unified control of the manifold, and the way of single pipe connection is used to control each group of radiators, and the pipe looks like an octopus from the appearance, so it is called the octopus connection method;
-
Underfloor heating and radiators can be mixed, but not very recommended.
Because the water temperature required for floor heating is inconsistent with the water temperature required by the radiator, the floor heating only needs about 45-50 degrees of low-temperature hot water, while the radiator needs about 70-80 degrees of high-temperature water.
If the original central heating was used for underfloor heating, then the radiators must be enlarged if they are used to install radiators. Because the water temperature is low, the radiator of the same size dissipates less heat than before, so the radiator must be increased to achieve the same heat in the room. The specific increase should be calculated in detail.
How to calculate can consult your local HVAC company.
Cooling mixed water center.
The temperature of the water used to feed the radiator is too high, and if you go directly to the floor heating, it will cause the floor to crack and the room temperature to be too high. It is clearly stated in the underfloor heating code that the inlet water temperature of underfloor heating is not allowed to exceed 60 degrees. Therefore, it is necessary to use a cooling and mixing center, whose function is to lower the temperature of the water entering the floor heating pipe.
No matter how you change it, it will increase the associated costs, so you need to think about it.
-
Central heating floor heating and radiators can be mixed, but the floor heating part needs to add a water mixing device.
The reasons are as follows: 1. The specification stipulates that the radiator central heating system should be designed according to 75 50 continuous heating, and the water supply temperature should not be greater than 85, and the temperature difference between the supply and return water should not be less than 20.
2. The specification stipulates that the water supply temperature of the hot water ground radiant heating system should be 35 45 and should not be greater than 60; The temperature difference between the supply and return water should not be greater than 10 and should not be less than 5.
3. After setting up the mixed sleeping device, ensure that the floor heating water supply temperature is lower than 60
-
Central heating floor heating and radiators can be mixed, now many northern cities are also mixed, bedrooms, living rooms are using floor heating, bathrooms do not use floor heating, are used radiators. However, it is not advisable to install additional radiators, as it is illegal to change the direction of the heating without authorization and add additional heating equipment.
-
In the case of central heating, floor heating and radiators should not be mixed, because they require different pressures. Even if you say that you succeed and install it, he will not be particularly warm, on the contrary, the floor heating personally feels very warm, as long as it is laid by your pipe. If it meets the national requirements, it will definitely be able to be warm.
-
Central heating, in principle, floor heating and radiators can not be mixed, because floor heating heating in order to ensure the service life of the floor heating pipe needs low-temperature water (feed water temperature can not be greater than 50), radiators belong to high-temperature heating equipment, the water temperature is too low thermal efficiency can not meet the requirements.
-
Collective heating, floor heating and radiators can not be mixed, floor heating to 60 degrees to start circulation, to the indoor 35 to 36 degrees, the temperature of the radiator is very low, the radiator is not hot enough, little use.
-
Technically speaking, it is possible to mix in this way, but if it is a collective heating household, it will involve some rules and regulations of the heating company, and it should be installed after asking for instructions.
-
It can be mixed, but it is very troublesome, you need to find a professional installation master, and the cost is more.
-
It can be, but their resistance is different, and there must be one that is not hot enough and cannot be connected at the same time. It is necessary to find a plumbing engineer to design and deal with it properly.
-
It is better not to, because it is easy to cause the temperature to be too high, and it is also more expensive.
-
Yes, this has nothing to do with whether it is central heating or not, a house that I rented before, the bathroom is the radiator, and the bedroom and living room are underfloor heating.
-
I guess it's okay, I've seen someone pick up a set of radiators before.
-
The working water temperature of floor heating is generally about 50 degrees, and the radiator needs to be about 70 degrees, so the boiler water can only be set to 70 degrees, and the water at this temperature is directly supplied to the radiator to use, and then the water cooled by the mixing center can be supplied to the floor heating pipe to use. However, if only one mixing center is added, the hydraulic partial pressure of the two systems needs to be adjusted many times to achieve balance, and the valve switch on the floor heating side will affect the working conditions of the radiator, so the best way is to add a coupling tank after the boiler hot water comes out, and after the coupling tank comes out, the three-way is connected to a water pump (a bypass valve needs to be added) directly into the radiator system, and the other end is connected to the mixing center (the water pump is linked to control) and then connected to the floor heating water divider. This system is the most stable and energy-saving, and the flow rate on both sides of the floor heating and radiator does not interfere with each other.
And the area of the house is relatively large, the boiler itself should cooperate with the coupling tank to do the system, and make the single-cycle system into the secondary side system of the coupling tank, so that the boiler can play the best efficiency.
Floor heating is divided into four parts: heat source, pipes, control, and insulation. Generally, the insulation part is called an auxiliary material. Mainly include: extruded plastic board, reflective film, boundary insulation strip, clamp nail, silicon crystal network, insulation sleeve, expansion joint, etc.
The auxiliary materials of radiators generally refer to accessories, such as wall covers, wire boxes, insulation sleeves, etc.
-
Floor heating and radiator mixing need to increase the pre-mixing center device, the pre-mixing center device is usually installed in the manifold, the reason for this is that the boiler produces only one temperature of hot water at the same time, the water temperature of floor heating is low-temperature hot water, the radiator needs high-temperature hot water, so it is necessary to install the pre-mixing center to make a part of the high-temperature hot water used in the radiator produced by the boiler become low-temperature hot water for floor heating circulation.
Generally, the choice of floor heating and radiator is to install a floor heating system in the room, a radiator heating system is installed in the bathroom, and a bathroom radiator can be used to dry towels and clothes, which is very practical. It is usually done to connect a set of radiators directly on the floor heating line in the bathroom.
-
Absolutely, but most of the time it is the installation of underfloor heating in other rooms and radiators in the bathroom, and Rubens Heating hopes to help you.
-
OK. Ground radiant heating is the most comfortable heating method, the indoor surface temperature is uniform, and the room temperature gradually decreases from bottom to top, giving people a good feeling of foot temperature and cold head; It is not easy to cause polluted air convection, and the indoor air is clean; Improves blood circulation and boosts metabolism.
The radiant heating method has higher thermal efficiency than the convection heating method, and the heat is concentrated in the height of the human body. Small heat loss during transmission; Low-temperature radiant ground heating can be controlled by layering, household and room, and users can regulate and control according to the situation to effectively save energy.
The radiator is a kind of heating-based heating equipment. It is mainly used in the northern region where the winter is cold, and has the effect of keeping warm, and cast iron radiators were mostly used in the past, but now more materials have been developed.
-
Floor heating radiators can be installed at the same time.
The mixed installation scheme of floor heating and radiator is more suitable for heating in large spaces such as duplexes or villas. In this way, the system of both floor heating and radiator, we call it the pre-mixed system, the pre-mixed system is higher than the pure radiator system or pure floor heating system, the overall cost will be higher, mainly because there is an additional set of pre-mixed center, the device is usually installed in the water collector, the reason for this is that the hot water produced by the boiler at the same time has only one temperature, the water temperature of the floor heating is low-temperature hot water, and the radiator needs high-temperature hot water. Therefore, it is necessary to install a pre-mixing center to turn part of the high-temperature hot water used in the radiator produced by the boiler into low-temperature hot water for floor heating circulation.
Example of a mixed installation scheme for floor heating radiators.
Floor heating in the common area of the living room, and radiators in the bedroom, because the owners generally stay in the public area of the living room and dining room at home, floor heating is more suitable for people's physiological needs, and the room is generally opened at night, and the use of radiators is more energy-saving.
The place with a solid wood floor is made of radiators, and the others are made of underfloor heating. The room with floor heating can not be installed with solid wood flooring, because the installation of solid wood floor heating needs to play keel, which causes a considerable section between the floor and the floor heating coil to be filled with air, and air is a bad conductor of heat, so that the room where the solid wood floor is installed has not been hot, and the other solid wood floor contains moisture, and it is easy to deform after being grilled for a long time.
If the customer has already chosen solid wood flooring, then only radiators can be made, and floor heating requires laminate flooring or multi-layer solid wood flooring. In some duplex houses, the owner wants to keep the wooden floor in the bedroom, so he asks for underfloor heating in the living room and radiators in the rest of the rooms.
It is cheap to spend radiators at one time, and if you pay according to the flow rate for a long time, you will choose floor heating
Good underfloor heating. 1.High thermal efficiency: Underfloor heating is actually radiant heating. As a result, underfloor heating is higher than convection heating mode. Underfloor heating concentrates heat to the benefit height of the human body. >>>More
1.Both radiators and floor heating need to lay pipes, and most of the pipes for floor heating are concentrated on the coils on the ground, so extra attention should be paid during construction. From the perspective of maintenance, if the floor heating leaks, the entire ground of the home needs to be pried open and the pipes of the floor heating need to be replaced. >>>More
Underfloor heating or radiators, which is better? Comparison of the advantages and disadvantages of radiators and floor heating.
It is turned on around the clock, and if it is used for a long time, the floor heating is more energy-efficient. >>>More