The fire intelligent lighting evacuation indication system is composed of a communication module, a relay communication module, a terminal evacuation lamp with an address code, and a standard serial communication port connected to the automatic fire alarm system, which integrates automatic monitoring, control, communication technology with centralized power supply (EPS) and fire emergency lamps, and uses communication interface circuits to link the system with the fire alarm system, and automatically generates the best evacuation route according to the evacuation channel situation. The intelligent emergency evacuation lighting system produced by Gongan Intelligent Technology can drive the dynamic indication of the safety exit direction of the marker lamp, the marker light and the emergency lighting lamp are the evacuation indication execution mechanism of the system, which is usually in the real-time inspection state, and when the fire is fired, after receiving the action command of the fire emergency lamp controller, its luminous indicator arrow is adjusted to illuminate or voice prompt according to the system command to complete the function of evacuation guidance.
It is mainly used in all kinds of buildings, in the event of a catastrophic emergency such as a fire, based on external information, according to the preset smoke and evacuation plan, the local evacuation path is optimized and adjusted, so as to provide safer, accurate and rapid evacuation guidance for the evacuation of personnel in the building. This new type of dynamic evacuation guidance concept breaks through the traditional guided evacuation scheme of static proximity guidance.
-
At present, the intelligent evacuation system of CIIC Shengan has been connected with a number of fire alarm hosts, such as: (foreign) ANSHE, Siemens, Nordifel, Tyco, Johnson Controls; (Domestic) Bay, Lida, Songjiang, Beida Jade Bird, Taihe'an, Fu'an, Yiai, Fanhai Sanjiang, etc.
-
Summary. Hello dear, according to the situation you described, the system that has nothing to do with the automatic fire alarm system can not be connected to the automatic fire alarm system.
Hello dear, according to the situation you described, the system that has nothing to do with the automatic fire alarm system can not be connected to the automatic fire alarm system.
Hello dear, according to the situation you described, the "Code for the Design of Automatic Fire Alarm System" (GB 50116-2013) gives the following provisions on the automatic fire alarm system: 1) The automatic fire alarm system can be used for places where people live and are often stranded, and places where important materials are stored or serious pollution after burning and need to be alarmed in time. 2) The automatic fire alarm system should be equipped with two kinds of trigger devices: automatic and manual.
3) The automatic fire alarm system equipment should be selected in line with the relevant national standards and relevant market access system products. 4) The compatibility of interfaces and communication protocols between various types of equipment in the system shall comply with the relevant provisions of the "Compatibility Requirements for Automatic Fire Alarm System Components" (GB 22134-2008). 5) The total number of devices and addresses such as fire detectors, manual fire alarm buttons and modules connected to any fire alarm controller shall not exceed 3200 points, and the total number of connected devices in each bus loop shall not exceed 200 points, and there shall be a margin of not less than 10% of the rated capacity; The total number of addresses of any fire linkage controller or the total number of hidden socks and various modules controlled by the fire alarm controller (linkage type) shall not exceed 1600 points, and the total number of connected devices of each linkage bus loop shall not exceed 100 points, and there shall be a margin of not less than 10% of the rated capacity.
6) Bus short-circuit isolators should be set on the system bus, and the total number of fire detectors, manual fire alarm buttons and modules and other fire-fighting equipment protected by each bus short-circuit isolator should not exceed 32 points; When the bus crosses the fireproof partition, a bus short-circuit isolator should be set at the crossing place. 7) In buildings with a height of more than 100m, except for the controllers installed in the fire control room, the fire detectors, manual alarm buttons and modules directly controlled by each controller should not cross the refuge floor. 8) The fire electrical control devices such as pump control cabinet and fan control cabinet should not be started by frequency conversion.
9) The automatic fire alarm system set up on the subway train should be able to transmit the information of the fire stove in the part of the train to the fire control room through wireless network and other means.
-
Answer]: a, b, c, e
The knowledge points assessed in this question are the content of the automatic fire alarm controller. The automatic fire alarm controller is the core of the entire automatic fire alarm and linkage control system, and the functions that must be possessed include: sound and light alarm function; Fault detection function; memory function; linkage output function; backup power; Networking.
-
Answer: a, b, c, e
The automatic alarm controller is the core of the entire automatic fire alarm and linkage control system, and must have the following functions: (1) sound and light alarm function; (2) Fault detection function; (3) memory function; (4) Linkage output function; (5) Standby power supply; (6) Networking function.
-
Answer]: b, c, d, e
The test site involved in this question is the function of the automatic fire alarm and fire linkage system. The functional family cover of the automatic fire alarm and fire linkage system is the detection of fire parameters, the processing and automatic alarm of fire signal and balance, the linkage and coordination control of fire fighting equipment, and the computer management of fire protection system.
-
Hello Kiss is happy to answer this question for you. Describe the five functions of automatic fire alarm and fire linkage control system: The role of automatic fire alarm system
1. The role is to minimize the damage caused by the fire to life and property, improve the success rate of falling off after the fire and minimize the loss 2, the composition of the alarm system, composed of the trigger device, the alarm device, the linkage device and the circuit power supply system 3, for the initial stage of the fire, the smoke and heat generated by the combustibles, after being collected by the detector, become an electrical signal, and the alarm controller will be transmitted to the alarm controller 4, and the control Zheng Tsai maker will start the sound and light alarm system after receiving the alarm signal. Remind nearby personnel to evacuate and evacuate, reduce the possibility of being trapped, and improve the safety and timeliness of personnel escape after the fire The main functions of the fire linkage controller include: control function, fault alarm function, self-test function, information display and query function, and power supply function.
Intelligent navigation system, intelligent collision avoidance system, intelligent braking system, intelligent safety system. >>>More
Founded in 2010, Wuxi Leading Sensing Technology Co., Ltd. relies on the R&D resources of Nanjing University of Aeronautics and Astronautics, in line with the principle of "people-oriented, policy-oriented; With the concept of "quality as the root, fruit as the root", we are committed to the application service and promotion of the Internet of Things and the development of related projects, and provide "package" solutions for enterprises that want to engage in the Internet of Things industry. Related products have great advantages in terms of quality, quality, and after-sales service. At the same time, it provides services for enterprises that want to engage in high-tech industries, want to upgrade their own industries, and want to improve the added value of product technology. >>>More
Scientific design home lighting system The family is generally divided into living room, bedroom, dining room, kitchen, study, bathroom, etc. Due to their different roles in the home, they can be differentiated to design the lighting of each part. >>>More
First of all, there are several pain points in the traditional building access control system, one is the high construction cost, because each household has an extension, coupled with the use of limited links, the cost of equipment and auxiliary materials and the project are very high; Second, because these intermediate devices are numerous and complex, they are easy to cause signal interference, resulting in a very high failure rate, and most systems are paralyzed or semi-paralyzed after 3-5 years; Third, the later maintenance is complex, because the line is buried through a weak current well, the later troubleshooting cost is high and complex, and the amount of work is huge. >>>More
To ensure the work of the inspection personnel, through fingerprint recognition, the handheld machine uploads the information of the inspection point, to avoid the inspection of the patrol personnel is not in place to replace the inspection and other problems is the use of RFID Internet of Things technology to achieve, want to know more can chat privately.