1. During the use of the water heater, condensation, dripping, rust and yellowing appear at the right end of the cover buckle. Open the right end cover for inspection, if there is a large amount of condensation, bile dripping, bile yellowing, water leakage, deformation of the heating tube, etc., it indicates that the bile mouth is not tightly sealed and there is water leakage, and the heating pipe should be disassembled for testing and maintenance.
Second, in fact, it is too troublesome to remove the repair and repair welding, and the repair cost is more expensive, and it is a pity to replace it with a new one, we can go to the plumbing accessories store to buy a cold water valve that matches the inlet pipe joint of the electric water heater. Turn off the main valve of the tap water, unscrew the hose fitting, replace the valve you just bought and check that the joint is not leaking.
3. When we heat the water heater, we should turn off the new valve, please rest assured that the water heater box is full of water at this time, and the water heater will never be boiled dry Every time you use the water heater, open the valve, and turn off this valve when you are not using the water heater. Make sure that the water heater box wall is under water pressure and it is safe to do so.
Fourth, it is not recommended to repair the inner tank if it leaks, because the inner tank enamel has been damaged, and it will not take long to repair it. From the direction of the dripping, such as a leak in the sealing ring or flange mouth, it may be solved by replacing the sealing ring.
Fifth, you can contact the manufacturer after-sales service, to see if the warranty period of your inner tank has passed, most manufacturers will replace the new machine during the warranty period, if the warranty period is over, then only buy again. Of course, you must report for repair of such a problem, and ask the manufacturer to send professional maintenance personnel to take a look.
First, we know that the water heater leakage is dangerous, and the blockage and corrosion of the fittings, the rupture of the fittings, the aging and rupture of the sealing gaskets of the fittings and other reasons. It is recommended to investigate from these three aspects, or find a professional maintenance master for inspection and maintenance; At the same time, pay attention to regular maintenance when using the water heater.
Second, if it is a leak from the outside of the gas water heater, the problem is not big, but it is better to fix it so as not to leak more and more, especially the interface belt. If it is the internal leakage of the gas water heater, don't use it anymore, and deal with it as soon as possible, it will damage the internal accessories. There are no hazards, they are two completely different systems, which have been designed with this in mind.
-
If there is a leakage pipe in the solar water tank when it rains, it may be that the water pipe is not installed well or there are holes in the water pipe to cause this situation, and it is recommended to replace it to ensure normal and safe use.
-
Please close the water heater inlet valve, and then use a wrench to re-tighten the original outlet connection pipe joint, which can generally solve the problem. If there is still a leak, replace the outlet pipe decisively.
1. The connection port between the water pipe and the joint, this depends on what kind of pipe you use, and the hot melt pipe is not well connected during hot melt and causes water leakage; In the case of aluminum-plastic pipes, the screws are not tightened or the sealing ring is damaged.
2. The connection between the joint and the water tank pipe, this is often caused by water leakage caused by the raw material belt not being wrapped well, so let the installer re-do it.
-
There are three pipes under the water tank, what is the reason for the leakage of the middle pipe.
-
1. Because the water pressure of tap water is too large, it will splash in the process of putting on the water, which will cause the water in the water tank to flow out of the exhaust hole before it is full, and the general solution to this phenomenon is to adjust the tap water pressure to the standard water pressure.
2. The leakage of the exhaust hole of the solar water heater may also be due to the fact that the return pipe is too long or not smooth, resulting in the water cannot flow out of the water pipeline in time after the water is full.
3. The leakage of the exhaust hole of the solar water heater is likely to be due to the fact that the water supply valve or solenoid valve is not closed tightly, resulting in the slow water supply, and the water will flow out of the exhaust hole after it is full. The solution is to close the water supply valve or repair the faulty part.
-
Some solar water heater exhaust ports are at the lower part of the water tank, and when the temperature in the water tank is too high, there will be soda dripping, and if it comes out, it is faulty.
-
In fact, the leakage of the water tank is relatively rare, if it is found that the tank is indeed leaking, then it is necessary to replace the new solar water tank. It is also possible that the solar water heater is leaking due to improper installation of the water tank, which only needs to be reinstalled.
Second, the solar valve is leaking.
The main reason for a valve leak is that the valve is faulty, and in this case, a new solar valve or solenoid valve needs to be replaced.
3. Water pipe leakage.
If the upper or lower water pipe is leaking, it is generally due to the aging of the long service time, and it is necessary to replace the solar water heating pipe with a new one.
Fourth, the solar exhaust port leaks.
The water leakage in this place is usually due to a damaged sensor or a damaged meter, so the water temperature level meter or solar meter needs to be replaced.
5. Leakage of solar heating tubes.
If the heating position leaks, then the electric heating is rusty and damaged, and a new sealing ring or electric heating rod needs to be replaced.
6. Water leakage at the solar vacuum tube.
The leakage at the vacuum tube is basically because the solar silicone ring is aging, and the old vacuum tube needs to be replaced with a new silicone ring.
7. Water leakage at the solar interface.
This interface mainly refers to the interface between the upper and lower water pipes and the water tank, where if the interface pipeline is not tightly connected, the pipe fittings will be damaged and the faucet will loosen, which will also lead to water leakage in the water heater.
8. Cracking and leakage of inner tank welds.
If the weld of the inner tank of the solar water heater cracks, it will also cause water leakage. Just replace the water tank or solder the open soldering area.
Question, oh, thanks.
-
That should be an electrically heated hole, it is installed in the form of a flange, it is estimated that the rubber ring is broken, and it would be good to have a new one, the problem is not big.
-
It may be the exhaust port, if the water flow is large, it means that the controller or solenoid valve is faulty, and the water is overflowing from the exhaust port.
-
The seal is aging, and it is recommended to disassemble and replace it with a new one.
-
What's going on with a leak in the exhaust air under the solar energy?
-
How to change the leakage of the solar cleaning hole.
-
Is this easy to unload, why can't I unload it?
-
Summary. Reasons for water leakage under the round mouth of the solar water tank:
1. If the solenoid valve is not closed tightly, and there is dirt in the solenoid valve, clean or replace the solenoid valve.
2. The water sensor is broken, the controller is powered off, and the water sensor parts are replaced. For the maintenance of solar energy, it should: 1. Regularly carry out system sewage discharge to prevent pipeline blockage; And clean the water tank to ensure that the water quality is clean.
2. Regularly remove dust and dirt on the transparent cover plate of the solar collector and keep the cover plate clean to ensure high light transmittance. Pay attention to check whether the transparent cover is damaged, and replace it in time if it is damaged.
3. For the vacuum tube solar water heater, it is necessary to check the vacuum degree of the vacuum tube or whether the inner glass tube is broken, when the barium-titanium getter of the vacuum tube turns black, it means that the vacuum degree has decreased, and the collector tube needs to be replaced. At the same time, the vacuum tube should be cleaned for reflection.
What's going on with the leaking hole under the solar tank.
The solar water tank refers to the reasons for the leakage of the round port: 1. The solenoid valve is not closed tightly, and there are dirt in the solenoid valve, so clean or replace the solenoid valve. 2. The water sensor is broken, and the controller is off, and the only way to change the water sensor parts is to change the gear.
For the maintenance of solar energy, it should: 1. Regularly carry out system sewage discharge to prevent pipeline blockage; And clean the water tank to ensure that the water quality is clean. 2. Regularly remove dust and dirt on the transparent cover plate of the solar collector and keep the cover plate clean to ensure high light transmittance.
Pay attention to check whether the transparent cover is damaged, and replace it in time if it is damaged. 3. For the vacuum tube solar water heater, it is necessary to always check whether the vacuum degree of the vacuum tube or the inner glass tube is broken, and the barium-titanium getter of the vacuum tube turns black, which means that the vacuum degree has decreased and the collector tube needs to be replaced. At the same time, the vacuum tube should be cleaned for reflection.
4. Inspect and inspect the pipelines, valves, float valves, solenoid valves, connecting hoses, etc. for leakage, and whether the heat-absorbing coating of the collector is damaged or falling off. All brackets, pipes, etc. are painted with protective paint once a year to prevent corrosion. 5. Prevent the circulation system from stopping the circulation and causing stuffiness, which will cause the internal temperature of the collector to rise, damage the coating, and cause the deformation of the insulation layer of the box, the glass breakage and cracking, etc.
The cause of stuffiness may be the blockage of the circulation pipe; In the natural circulation system, it may also be caused by insufficient cold water supply and the water level in the hot water tank is lower than the upper circulation pipe; In a forced circulation system, it may be caused by the circulating pump stopping to work.
-
Summary. Pro, the leakage fault of solar water heater is a fault with a relatively high failure rate of solar maintenance.
Pro, the leakage fault of solar water heater is a fault with a relatively high failure rate of solar maintenance.
There are mainly these situations of lead leakage in the hole under the solar water tank: (1) The vacuum tube is damaged and leaking, the welding port is cracked, and the exhaust tee is leaking. (2) Water leakage at the interface between the upper and lower sewer pipes and the water tank (the reason is that the pipeline connection is not tight; Pipe fittings are damaged; Loose faucet), shower leaking (reason:
Bad valves or broken metal hoses. (3) Water leakage caused by bad sealing gasket or poor connection, water leakage at the connection between the vacuum tube and the water tank (reason: the silica gel ring is damaged or poorly sealed; The inner tank is not concentric with the outer shell).
Hope mine is helpful to you.
Can it be just sealed?
Yes, as long as it doesn't leak.
Okay, thanks!
Have a great day!
-
Summary. Hello! We're glad to answer your questions! After the solar rain solar water pipe leakage, the problem is not particularly big, you directly turn off the water supply pipe, and replace the leaking position into it.
Hello! I'm glad Sakurayu answered for you! Sun rain solar energy spine this pin a water pipe leakage is the solar water pipe leakage after the problem, the problem is not particularly big, you directly turn off the water supply pipe, the leakage position to replace the drop on the line.
Hello! We're glad to answer your questions! Solar rain refers to a leaky weather phenomenon that occurs when the sun is shining on a sunny day.
Some sun rain is caused by dark clouds in the distance, which are blown to another place by strong winds. Some of them are formed because two clouds with different charges collide with each other under the action of the solar wind, resulting in excessive water vapor content in the air in local areas, and the first time to search for the water vapor to evaporate faster due to solar radiation.
-
Summary. Pro: The inlet pipe of the solar water tank is leaking, it is recommended that you take the following measures: Turn off the water source:
First of all, you need to turn off the water source to avoid the leakage from worsening and causing more damage. Check the inlet pipe: Check the inlet pipe for damage or looseness, and if a problem is found, you can reinstall or replace the inlet pipe.
Check the gasket: Check the gasket at the connection between the water inlet and the inlet pipe of the tank, and replace the gasket with a new one if the gasket is aged or damaged. Contact after-sales service:
If you can't solve the problem by yourself, you can contact the after-sales service of the solar tank and seek professional repair and help.
Pro: The inlet pipe of the solar water tank is wide and leaking, it is recommended that you take the following measures: Turn off the water source: First of all, you need to turn off the water source to avoid the water leakage from aggravating and causing greater losses.
Check the inlet pipe: Inspect the inlet pipe for damage or looseness, and if you find a problem, you can reinstall or replace the inlet pipe. Check the gasket sprambling:
Check the gasket at the connection between the water inlet and the inlet pipe of the tank, and replace it with a new gasket if the gasket is aged or damaged. Contact after-sales service: If you can't solve the problem by yourself, you can contact the after-sales service of the solar tank to seek professional repair and help.
I have a solar water heater for solar rain, and the inlet and outlet connections below can be twisted but can't be screwed down, what should I do?
The inlet and outlet water joints under the solar water heater can be twisted but cannot be unscrewed, which may be due to the fact that the joints have been aged, deformed or corroded, resulting in the threads at the connection between the joints and the water heater being stuck. It is recommended that you take the following actions: Use appropriate tools:
You can use a suitable tool (such as a wrench, pliers, etc.) to try to unscrew the fitting, but be careful not to use too much force to avoid damaging the water heater or fitting. Lubricant: You can spray some lubricant on the fitting, such as oil or lotion, to relieve the thread seizure before trying to unscrew the fitting.
Water Heater Heating: While using the lubricant, you can heat the water heater for a while before attempting to unscrew the fittings. Due to the principle of thermal expansion and contraction, the heated fitting may be easier to remove.
Seek professional help: If you are unable to solve the problem by yourself, it is recommended that you seek the help of professional after-sales service or maintenance personnel to avoid unnecessary losses and dangers.
1. Find a professional maintenance personnel to replace the solar collector tube. 2. To reinstall the pipe fittings of the solar water pipe, it is generally necessary to screw the small steel pipe out of place before it can be used. 3. To the leaking water tank mouth, you need to take out the inside of the silicone ring and slowly buckle the new silicone ring in the notch. >>>More
It's very cheap, my family changed to a 24-tube one last time, and it cost 500 yuan, and I think your family is more than 300 yuan
Developed countries have long proposed possible implementation plans for future solar power generation. >>>More
Polar ultra-cold tube, is the use of UTLET technology, interference membrane technology is a kind of vacuum tube, vacuum degree of 10 4 Pa, the inner membrane will not fall off and whitish within 15 years, is the type of vacuum tube of Huangming's high-end model, this is the vacuum tube selected by the Antarctic scientific expedition team, minus 40 degrees of thermal insulation performance and thermal efficiency improvement ability is still very good. The high-temperature tube and high-efficiency tube are actually ordinary vacuum tubes on the market, with a vacuum degree of 10 2 Pa, which is also very cheap. If you have to go from the outside, the purple color of the Huangming vacuum tube is heavier, you can stand up and try it, the real Huangming utlet polar tube can be flattened for four people without a problem.
What is the price of Huaziguang solar dual-purpose water heater?