If the indoor unit has the same clicking sound as the mechanical timer, and it continues, it is most likely an installation problem. At this time, if you press the shell of the indoor unit with your hand, the sound will decrease or disappear, indicating that the installation plate of the indoor unit is not attached to the wall, or the wall is uneven. You need to stick the base plate to the wall, or smooth the wall to solve the problem.
Check the evaporator for dust or foreign objects. If there is, clean it up. It can be rinsed with clean water.
If it won't be disassembled, ask a professional to clean it. Precautions for using air conditioningReasonable use of air conditioning is helpful for children's health: In fact, because of the child's poor adaptability to temperature, it will not be able to sleep well at night because of the high temperature, which can easily lead to inflammation, heat stroke, heat sensation and other problems.
The rational use of air conditioning not only helps to create a comfortable temperature environment, but also achieves the effect of dehumidification, so that children are protected from the threat of dampness and heat. Make good use of the dehumidification function: the weather is hot and uncomfortable, the child's sweating system is still developing, and it is easy to have rashes, prickly heat and other diseases.
Take advantage of the dehumidification function to reduce the humidity in the room, so that you can feel comfortable and refreshing even if you don't lower the temperature of the air conditioner.
-
Hello, the abnormal noise of the air conditioner may also be loose screws, if it is not the case of loose screws, you must find a professional master to repair, if the screws are loose, you can enter it for a while.
-
The clatter of the outside unit of the air conditioner can be caused by the following reasons:
1.Loose or worn fan blades: When the submerged fan blades are loose or worn, it will cause the external unit to make a clicking sound.
2.Compressor failure: The compressor is the core component of the air conditioner's external unit, and if the compressor fails, it will cause the external unit to make a clicking sound.
3.Insufficient refrigerant or air leakage: When the refrigerant of the external unit of the air conditioner is insufficient or leaking, it will cause the external unit to make a clicking sound of liquid and substances.
4.Fan motor failure: When the fan motor fails, it will cause the external unit to make a clicking sound.
If your air conditioner makes a rattling sound, it is recommended to contact a professional air conditioner maintenance personnel immediately for inspection and maintenance.
-
The solutions to the abnormal noise of the air conditioner are to check whether the fan bearing is aging, check the rotor blades, clean the air filter, repair the compressor, and check the motor.
1. Check whether the fan bearing is aging.
If the abnormal noise of the internal machine is relatively light, you can check whether the fan bearing is aging. The machine can be disassembled, the bearings can be oiled, the dust can be cleaned with cleaning solution, and then reinstalled to see if the sound decreases.
2. Check the rotor blades.
If there is an imbalance when the fan rotates, it is most likely because the fan blades are not installed correctly. At this time, it is necessary to check whether the fan blades are damaged or damaged, and if there is any leakage, it needs to be replacedIf not, it needs to be reinstalled so that it rotates and balances.
3. Clean the air filter.
If the air filter is dirty, it will cause the load on the fan to increase, resulting in an abnormal rattling sound. At this time, it is necessary to clean or replace the air filter, and regular cleaning will make the air conditioner more closed, healthy and environmentally friendly.
4. Repair the compressor.
If the internal machine is loud, it is possible that the compressor is faulty. At this time, it is necessary for professionals to inspect and repair, and it is impossible to deal with it by yourself.
5. Check the motor.
If the sound of the internal machine is intermittent, the clump may be caused by poor contact of the motor. At this time, it is necessary to check the motor connection and adjust the rotation angle of the motor, which may solve the problem.
-
The rattling of the outside unit of the air conditioner may be caused by the following reasons:
1.Loose or worn fan blades: When the fan blades are loose or worn, it will cause the external unit of the air conditioner to make a clicking sound.
2.Compressor failure: The scrambler compressor is the core component of the air conditioner, if the compressor is faulty, it will cause the air conditioner to make a clicking sound.
3.Insufficient refrigerant: If the refrigerant of the external unit of the air conditioner is insufficient, it will cause the compressor to work abnormally, resulting in a clattering sound.
4.Fan motor failure: The fan motor is the part that controls the rotation of the fan of the air conditioner, if the fan motor fails, it will cause the air conditioner to make a clicking sound.
If your air conditioner makes a clattering sound, it is recommended that you contact a professional air conditioner maintenance personnel in time for inspection and repair.
Xiaomi air conditionerThe causes and solutions of abnormal heating noise are as follows: >>>More
1.If the installation stability of the indoor unit is not good, when the outdoor unit of the air conditioner is running, the copper pipe is connected to the indoor unit. If the indoor unit is not stable enough, it will be affected by the compressor, resulting in the resonance of the indoor unit. >>>More
See if it's one of the following reasons:
1.When the air conditioner is started or stopped, it is normal for the plastic parts of the internal unit to make a sound due to the expansion and contraction of the internal unit due to temperature changes. There are also some pipelines that are deformed due to thermal expansion and contraction, and are attached to the compressor or metal shell, causing resonance. >>>More
1. The voltage of the power supply is not enough.
Solution: Maintain a normal supply voltage. >>>More
Gree air conditioner display E2 is anti-freezing protection, plate heat exchanger anti-freezing protection, evaporator anti-freezing protection, anti-low temperature, the specific cause of the fault needs professional service personnel to come to the door to detect and troubleshoot, please click on the self-service report or call Gree national unified after-sales service**4008365315 feedback your needs and suggestions.