<> winter and summer start-up is the same, refrigeration is run like this, heating is opposite, air humidity is high, if the outdoor temperature is as low as zero, the water will become ice, and it is necessary to pay attention to snow removal and ice shoveling on snowy days. At present, most of the air conditioners produced in our country are of T1 climate type. Therefore, when operating under refrigeration conditions in summer, when the outdoor temperature exceeds 43, the air conditioner will not be able to cool normally or the work efficiency will be very low; In winter, when the ambient temperature is lower than minus 7, the air conditioner cannot work normally or the heating efficiency is very low.
Generally, air conditioners are equipped with defrosting circuits:
1 For heat pump air conditioners in winter heating work, the surface temperature of the evaporator will reach below zero, the surface of the evaporator may be frosted, and the thick frost layer will cause the air flow to be blocked, affecting the heating capacity of the air conditioner, so there is a defrosting circuit on the air conditioner. There are generally two kinds of defrosting circuits, one is to stop the defrost and let the frost melt by itself, which is not feasible when the temperature is low, and the time to melt the frost is longer, and the air conditioner generally does not use this method. The other refers to thermal defrosting, that is, the use of changing the reversing valve to make the evaporator condenser on the indoor side can also be regarded as the meaning of the exchange of internal and external machines to achieve the effect of initial frost.
The defrosting controller is also an electrical switch that uses temperature to control the operation of the contacts.
2 Micro differential pressure gauge defrost controller. It uses a microdifferential manometer to feel the pressure difference between the outdoor unit before and after frost and controls it by itself. The high voltage of the micro differential pressure gauge defrost controller is connected to the air inlet side of the outdoor evaporator surface, and the low pressure is connected to the air outlet side of the outdoor evaporator surface.
After the outdoor evaporator frosts, the airflow resistance increases, and the pressure difference between the front and rear changes, so that the defrosting circuit is turned on, so that the electromagnetic power is cut off and the defrosting is turned. You can try to change the automatic mode to the heating mode, FYI.
-
Because it's cold, the air conditioner works intermittently and has to be frosted.
-
Normal, defrosted, outdoor humidity, you can observe it.
-
Midea's fixed-frequency air conditioner will automatically stop heating for a while, and it will be started for a while, which is related to air conditioning and defrosting.
Causes and solutions.
1. Air conditioning defrosting. After the air conditioner is heated for a period of time, it will automatically enter the defrosting, and the air conditioner will stop running when the defrosting is completed, and the air conditioner will resume operation after the defrosting is completed, which is a normal phenomenon and does not need to be solved.
2. The indoor temperature reaches the set temperature. After the indoor temperature reaches the set temperature, the air conditioner will stop running, and when the indoor temperature is different from the set temperature by a certain temperature, the air conditioner will resume operation, and it is recommended to increase the temperature appropriately.
3. The air conditioner filter is too dusty. After the air conditioner filter is used for too long, the filter is blocked due to excessive dust, which in turn leads to poor air outlet of the air conditioner and a decrease in heating effect, so it is recommended to clean the filter.
-
The air conditioner was turned on for a while and stopped automatically for the following reasons:
1. If the air conditioner stops just after it is turned on, then the user should first consider that the air conditioner is abnormal because of the short circuit or short circuit phenomenon of the line. For this fault situation, it is recommended that users find a professional electrician to test the wiring at home to see if there are potential safety hazards.
2. It may also be caused by the unstable voltage at home, if the voltage at home is unstable, the air conditioner will naturally stop running for a while, and a voltage regulator should be installed at home.
Or turn off the air conditioner and wait for the voltage to stabilize at home before using it.
During the peak period of electricity consumption, there may also be a phenomenon that the air conditioner will stop running for a while, which generally occurs in summer, because at this time, every household will use the power appliance of air conditioning, so some areas will be prone to voltage instability.
3. Damage to the compressor in the air conditioner will also cause the air conditioner to run for a while and then suddenly lose power. The compressor is an important part of the air conditioner, once the compressor fails, then the air conditioner is bound to be able to start normally, and it is necessary to ask a professional maintenance master to come to the home to repair and detect the fault.
4. If the filter screen of the indoor unit is too dirty, the fan speed is too slow, and the outdoor unit fin-shaped aluminum foil heat sink.
If it is too dirty, the fan speed is too slow, or the blades are broken and deformed, the temperature exchange of the air conditioner will not be smooth. In addition, this situation will also occur when the outdoor unit is exposed to the sun for a long time, which affects ventilation and heat dissipation.
5. It may be caused by the air conditioner turning on the self-protection mode, when the refrigerant of the air conditioner.
When there is a deficiency, the air conditioner will turn on the self-protection mode, and it will stop running every time it runs, so as to avoid the air conditioner being damaged, and then you need to ask a professional to help add refrigerant.
-
There may be three reasons why Midea's air conditioning heating is always suspended.
1. When using Midea air conditioners in winter, in order to make the temperature meet the required requirements, it is usually set according to the actual ambient temperature. However, when the temperature of the Midea air conditioner reaches the required temperature, the air conditioner will stop supplying air.
At this time, Midea's air conditioner will stop working. Wait for the temperature difference to appear again, and the Midea air conditioner will continue to work again. This is normal.
2. When using Midea air conditioners, many people are used to putting the baffle of the air conditioner up. However, due to the fact that when Midea air conditioner heats up, the heat rises. Therefore, this practice can easily lead to the fact that the indoor temperature cannot meet the set requirements.
On the other hand, the thermostat that comes with the Midea air conditioner only feels the temperature at the baffle, thinking that the temperature set by the air conditioner has been reached. So it stops automatically. In this case, you can simply change the direction of the bezel.
3. Sometimes the heating of the Midea air conditioner stops after a while, and it may be caused by the air conditioner being defrosted. Since the air conditioner will have heat exchange and frost when heating, in order to maintain normal operation, Midea air conditioner will start to defrost after using it for a while.
During the defrosting process, Midea's air conditioner will stop supplying air, so the air conditioner will shut down. But there is no need to worry, because when the defrosting work is completed, the Midea air conditioner will start heating again.
-
Hello dear, according to your problem description, Midea air conditioner will automatically shut down after a while, your air conditioner should belong to the inverter air conditioner, and should not be close to the indoor temperature in terms of temperature setting. If the temperature is close to the indoor temperature after reaching a certain temperature. The air conditioner will automatically stop and turn it back on when the temperature drops.
-
The common reason is that the air conditioner is malfunctioning due to improper use or aging of the air conditioner. If the operation is improper, the main thing is to turn on the timer mode or sleep mode, as long as the scheduled time node is reached, the air conditioner will automatically stop, which is a normal phenomenon, as long as it is restarted. How to deal with the automatic stop of the air conditioner:
Check whether the starting capacitor of the cooling fan of the outdoor unit is damaged, the temperature will be too high if the fan does not rotate, and the system will play a protective role, thus stopping the air conditioner, which can be seen by the naked eye, if it is because the starting capacitor is damaged, the fan starting capacitor needs to be replaced. If there is a shutdown during heating, it may be caused by air conditioning defrosting, because the air conditioner causes frosting due to heat exchange when heating, and the air conditioner can defrost itself after working for a period of time, so the air conditioner will shut down, and the heating will be resumed after the defrosting is over, without any treatment.
-
It may be that the air conditioner has been used for a long time, and there is a leak or leakage of refrigerant, resulting in a decrease in refrigerant, which causes problems with the heating effect of the air conditioner. It is recommended that users find a professional to add refrigerant.
The air conditioner reaches the set temperature: Generally, when the air conditioner starts heating, the temperature will be adjusted to, for example, the heating of the air conditioner is adjusted to 20 degrees, and the indoor temperature of the air conditioner has reached 20 degrees after the heating has been working for a certain time, at this time the air conditioner will stop supplying air, that is, the air conditioner will stop heating for a while. If you want to determine if this is the cause, you just need to turn up the temperature again and see if the heating of the air conditioner starts again.
-
Summary. Hello, glad to be able to your question. The reasons and solutions for stopping the Midea air conditioner after a while are as follows:
1. The compressor stops secretly, generally there is too much dust on the evaporator, and cleaning the dust on the evaporator can solve the problem. 2. Connect the faucet with a water pipe, spray water on the evaporator, turn on the power supply of the air conditioner, if the air conditioner is no longer secretly stopped or shut down at this time, it is not good for heat dissipation, and it is OK to clean the evaporator. 3. Failure of the compressor itself.
The common Midea air conditioner outdoor compressor start-stop fault is caused by the following reasons: 1. The external unit is exposed to the sun, the ventilation is blocked, etc., the condensation effect is not good, the exhaust pressure is too high and the machine is stopped, please remove the obstacle 2, the abnormal high voltage or low voltage, the compressor cannot be started, the current is too large, and the overload protector is shut down. 3. Wrong wiring.
4. The power grid capacity is insufficient, the line voltage drop is large, and the current is overcurrent, resulting in the shutdown of the action surface of the overload protector. 5. The outdoor temperature is too high. When the condensing pressure rises and the compressor is overloaded, the protector automatically cuts off the power supply and stops the machine.
If the air conditioner is running normally, the wind speed can be set to medium or low cooling, so as to reduce the cooling load and keep the air conditioner running. 6. Poor or damaged capacitor contact, so that the compressor can not operate normally.
Thank you. Hello, glad to be able to your question. The reasons and solutions for stopping the Midea air conditioner after a while are as follows:
1. The compressor stops secretly, generally there is too much dust on the evaporator, and cleaning the dust on the evaporator can solve the problem. If the air conditioner is no longer stopped or shut down at this time, it is not good to dissipate heat, and it is OK to clean the evaporator. 3. Failure of the compressor itself.
The common Midea air conditioner outdoor compressor start-stop fault is caused by the following reasons: 1. The external unit is exposed to the sun, the ventilation is blocked, etc., the condensation effect is not good, the exhaust pressure is too high and the machine is stopped, please remove the obstacle 2, the abnormal high voltage or low voltage, the compressor cannot be started, the current is too large, and the overload protector is shut down. 3. Wrong wiring.
4. The power grid capacity is insufficient, the line voltage drop is large, and the current is overcurrent, resulting in the shutdown of the action surface of the overload protector. 5. The outdoor temperature is too high. When the condensing pressure rises and the compressor is overloaded, the protector automatically cuts off the power supply and stops the machine.
If the air conditioner is running normally, the wind speed can be set to the medium cooling or low cooling gear to reduce the refrigeration load and continue to run the air conditioner. 6. Poor or damaged capacitor contact, so that the compressor can not operate normally.
-
Because the air conditioner is defrosting. When the air conditioner is heating, it is indoor hot air, and the outdoor unit of the air conditioner is cold air, at this time, the condenser heat exchange will be because the outdoor temperature is too low, and the phenomenon of frost or ice will occur, so in order to ensure the normal use of the air conditioner, it is necessary to defrost the air conditioner. When the air conditioner defrosts, the indoor unit will stop running, and the four-way valve will be reversed, so that the outdoor unit of the air conditioner will blow hot air to defrost, generally about 3-5 minutes, generally no more than 10 minutes.
Therefore, the phenomenon of Midea air conditioner will shut down when it is heating, which is a normal defrosting phenomenon of the air conditioner. And if the air conditioner defrosts for too long, that is to say, if the air conditioner has too long downtime or frequent shutdown, then it may be that the air conditioner ** is malfunctioning, because this is not a normal phenomenon of the air conditioner. At this time, it is necessary to detect and repair the fault phenomenon of the air conditioner accordingly.
-
If your Midea air conditioner is heating up and will turn on and off, it may be one of the following reasons:
1.Temperature sensor failure: The air conditioner is equipped with a temperature sensor to control whether the indoor temperature reaches the set value. If the sensor fails or fails, the air conditioner will not be able to detect the indoor temperature correctly, and the fan will be unstable.
2.Water valve problem: Some models of air conditioner maintenance add less water, so when the maintenance time is slightly longer or the normal performance of the filter is reduced, there may be problems such as insufficient water level and poor water supply pipeline, which will lead to the failure of the air conditioner to turn on and stop.
3.Cooling capacity problem: When the ambient humidity is high or the outdoor temperature is low, the heating effect may be affected, and the amount of freon or the failure of the electronic valve will also cause the heating of the air conditioner to fluctuate, resulting in the phenomenon that the air conditioner will turn on and stop.
Here's how to deal with it:
1.Check the aircon settings and clean the filter: Check that the aircon is set up correctly, and then clean the filter to make sure it is working properly.
2.Confirm that the gas or power supply is stable: Make sure that the gas line is unblocked, whether the power supply is overloaded or other settings are selected incorrectly, and check whether the normal power supply** or capacity is affected.
3.Contact professional service for repair: If the problem persists, please contact professional technical support, usually the staff will be on site to identify and repair the problem in detail, if there is an aging equipment and other situations that need to replace parts, it will also provide corresponding advice.
1.The four-way valve is broken, and the possible reason is that the four-way valve wire is off, the four-way valve coil is burned out, and the nylon ball inside the four-way valve is blocked. Solution: Replace the four-way valve to solve the problem of air conditioning not heating. >>>More
Midea air conditioning. The reason why the heating is not very hot: In the long-term use of the air conditioner, the air conditioner does not heat may be the refrigerant. >>>More
Midea air conditioning. The reason why the heating is not very hot: >>>More
Will convert the frequency by itself.
Inverter air conditioning. basic structure and refrigeration principle. >>>More
Many people think that when the room temperature drops, the air conditioner should be turned off, and then turned on when it is hot, thinking that this can save electricity, in fact, whether the air conditioner saves electricity depends to a large extent on the number of times it is turned on, and the air conditioner is the easiest to consume electricity when it is turned on and off, especially when it is started, and it is easy to lose the compressor. The correct approach is: set the air conditioner to a high cold state when turning on to achieve the purpose of cooling as soon as possible, and when the temperature is suitable, change the medium and low wind to reduce energy consumption. >>>More