Temporary electricity consumption refers to the new electricity consumption for drought resistance, flood drainage and other electricity consumption that needs to be set up in the power department in addition to the household meter of the power department, and the electricity consumption time of the new power supply is generally not more than 1 year.
Temporary electricity consumption does not include the electricity consumption that has been installed by the power department for a fixed power connection device in a periodic and seasonal manner, such as power equipment such as threshers, small electric pumps, and black lights.
Management system. 1. For all temporary electricity consumption, the electricity unit or individual shall go through the application procedures with the power supply station, and the electricity can only be used after the two parties sign the power supply agreement and install the design meter.
2. All temporary electricity should be equipped with leakage protectors and short-circuit and overload protection, and surge protection should also be installed in areas with frequent lightning.
3. If it is necessary to erect lines for temporary electricity, it shall comply with the relevant provisions of the "Technical Regulations for Rural Low-voltage Power".
4. Temporary electricity shall not be transferred to power supply. At the end of the electricity consumption, the power supply station shall dismantle the temporary electricity device, and it is not allowed to directly convert the temporary electricity into formal electricity consumption.
-
As defined in GB 30871.
Temporary electricity consumption: refers to the non-permanent electricity connected to the power supply that is officially in operation.
It can be understood as: the generator is the official power supply for the operation of the system, then the power connection on the system is a temporary electricity operation, if the generator is only for the temporary electrical equipment to supply power, it does not belong to the temporary electricity operation.
But GB 30871.
Special operations: operations that may cause harm to the safety of the operator, others and surrounding buildings, equipment and facilities that may be involved in the process of equipment maintenance, such as fire, entering restricted spaces, blind plate plugging, high-altitude operations, hoisting, temporary electricity, earth moving, circuit breaking, etc.
It is understood that: In accordance with the principle of people-oriented, in order to protect the safety of the operator, all informal electricity consumption exceeding the safety voltage of 36V should belong to temporary electricity operation.
-
Generally, it is a temporary power supply facility and line applied for during building construction. Including transformers, lines, meters, etc. Permission from the Power Supply Bureau is required.
-
Legal analysis: 1. Non-residents need to provide the following information for temporary electricity use: customer identification information, and non-personal handling must also provide the identity information and power of attorney of the person in charge, and the property ownership certificate information of the electricity address (this information is not required to be provided for the increase of electricity consumption within the original electricity consumption range).
Customers who have special requirements for electricity consumption and have an impact on the quality of power supply must provide a list of electrical equipment.
2. The relevant payment information to be submitted by the customer who handles the bank deduction of electricity charges (no need to provide for capacity increase), and other information expressly required by the department or power supply regulatory agency. Temporary electricity customers are required to provide relevant information on the permanent electricity consumption plan.
Legal basis: "Safety Code for Electricity Supply and Consumption at the Construction Site of Construction Projects" 1Establish a system for the preparation and approval of temporary electricity construction organization design and technical measures for safe electricity use, and establish corresponding technical files.
2.Establish a technical disclosure system. Introduce the overall intention, technical content and precautions of the temporary electricity organization design and safe electricity use technical measures to professional electricians and all kinds of electricity users, and should perform the signature procedures of the person who made the disclosure and the person to be disclosed on the technical disclosure text, and indicate the date of disclosure.
3.Establish a safety inspection system. Starting from the completion of the temporary power project, the temporary power project is regularly tested, and the main contents are:
Grounding resistance value, electrical equipment insulation resistance value, leakage protector action parameters, etc., to monitor whether the temporary power project is safe and reliable, and make a test record.
4.Establish an electrical maintenance system. Strengthen daily and regular maintenance work, find and eliminate hidden dangers in a timely manner, and establish maintenance work records, remember and train maintenance time, place, equipment, content, technical measures, early bright macro results, maintenance personnel, acceptance personnel, etc.
5.Establish a system for project demolition. After the completion of the construction project, the demolition of the temporary power project shall have a unified organization and command, and the demolition time, personnel, procedures, methods, precautions and protective measures shall be stipulated.
6.Establish a safety inspection and assessment system. The construction management department and the enterprise shall regularly inspect and evaluate the on-site electricity safety in accordance with JGJ59-88 "Construction Safety Inspection and Scoring Standards".
7.Establish a responsibility system for safe electricity use, and implement the operation, supervision, and maintenance of each part of the temporary electricity project to the person, and supplement it with necessary rewards and punishments.
8.Establish a safety education and training system. Regularly carry out education and training on electricity safety for professional electricians and all kinds of electricity users, and all personnel must hold a certificate issued by the labor department, and it is strictly forbidden to work without a license.
-
Temporary electricity at construction sites must be applied to the local power supply department.
Temporary electricity consumption for unmetered customers. >>>More
Long-term medical advice. It is a clinical operation (such as taking medication, infusion, etc.) that needs to be carried out on time and quantitatively every day after admission to before discharge. >>>More
Fines must be paid in accordance with the regulations.
A chef is a person who takes cooking as his profession and cooks dishes as his main job. The profession of chef appeared very early, and there were already full-time cooks in slave societies. With the continuous improvement of the material civilization of society, the chef profession is also developing, and the team of full-time chefs is constantly expanding. >>>More
1. Self-cursed version of the reason for leave: illness, such as allergies, gastroenteritis, etc. Requires excellent acting skills, reasonable **. The success rate is 80% and the technology is 100%. The rate of being recognized is extremely high, but the bosses are embarrassed to wear it. >>>More