After powering on 6518 or 1518 or 6368, quickly press the "tare " button and half a "0" appears in the unit price window
Press the "1" button, and then press the "tare" button, and the unit price window will appear "2", and the amount window will appear "--
Put on the 10kg weight, press the "tare" button, "3" appears in the unit price window, and "0" appears in the amount window
Enter the weight of the weight, that is, 10kg input 10000 press the "tare" key (if you change the pound, the weight is 20000).
Enter the maximum weight (for example, enter 30000 for a 30kg scale), press the "tare" button, the unit price window will appear "5", and the amount window will appear "0" (if the market is changed, the weight will be entered 60000).
Enter the index value (for example, input 10 is 10g, input 5 is 5g, input 2 is 2g, input 1 is 1g) press the "tare" key, the weight of the weight root shows the same weight, that is, the calibration is successful.
-
1.After powering on, press 6368 or 1518 or 6518, and quickly press the "tare" button, and half a "0" will appear in the unit price window.
2.Press the "1" button and then press the "tare" button, the unit price window will appear "2", and the amount window will appear "--
3.After putting the 10kg weight, press the "tare" button, the unit price window will appear "3", and the amount window will appear "0".
4.Enter the weight of the weight 10kg and press the "Tare Away" button. (If you want to change the pound, enter the weight 20000).
5.Enter the maximum weight (for example, enter 30000 for a 30kg scale) and press the "Tare" button, the unit price window will appear "5", and the amount window will appear "0". (If you want to change the pound, enter the weight 60000).
6.Enter the index value (for example, input 10 is 10g, input 5 is 5g, input 2 is 2g, input 1 is 1g) and press the "tare" key, the weight of the weight is the same as the displayed weight, that is, the debugging is successful.
If the above steps cannot complete the calibration, it is recommended to contact the after-sales service of the electronic scale.
-
I sell electronic scales. 3658, 1578, 1589, 1680, try.
-
I can't tune it.
How do you transfer kilograms to pounds of this kind of electronic scale (Jiayou electronic scale).
-
The password of Jiayou electronic scale is: 975 Open the cover, plug in the short-circuit ring, and turn it on. Press the "9 7 5" key, and then press the "Tare Down" key.
The unit price window displays a "0". Enter 97528 again, press the "Tare" button for a few seconds, and "Pure Closed" will be displayed. Add 1 3 weights.
Press the "Peel Xiaola" button again to display "load 0". Enter the weight value for the weight, and then press "Tare Away". Enter the full travel value for the weight.
S press "Peel" again. Commissioning is completed in a few seconds. (Note:.)
The 24-key debugging weight and the 14-key method are the same, the difference is that the three-point electronic pricing scale debugging method Open the cover and plug in the short-circuit ring to start the machine to do careful cracking. The unit price window displays a "0". After pressing the "918" key and pressing the "Accumulation" button for a few seconds, it shows "load——— plus 1 3 weights.
Press the "Total" button again, enter the weight value of the weight, and then press "Total". Enter the full travel value for the weight. Then press "Cumulative" to enter the graduation value.
21 is single-range and 22 is two-range. Then press "Accrual".
-
The calibration method of Jiayou electronic scale is to use weights to calibrate.
The steps to correct the wheel beam with weights are as follows:
1. Empty the weighing pan and calibrate the zero point first. (as shown in the image below).
2. According to the maximum weighing of the electronic scale, find one (or more) standard weights, and the weight requirements are within the range of the maximum weighing. According to the steps given in the manual, enter the weight of the weight into the range value column, calibrate the range, and repeat the zero point and the range several times.
Precautions for the use of electronic scales:
1. It is strictly forbidden to rain or rinse with water, if you accidentally get wet, wipe it with a dry cloth, and send it for repair as soon as possible when the machine is not functioning properly.
2. It is strictly forbidden to knock on and press hard.
3. Do not place it in high temperature and humid environment (except for special waterproof and anti-corrosion scales).
4. If the electronic scale is not used for a long time, the machine must be wiped clean, put in the desiccant and wrapped in a plastic bag, and the dry battery should be used. Otherwise, the battery will rust and corrode the scale.
How to use electronic scales:
1. Place the electronic scale on a horizontal table and place it stably.
2. Turn on the power supply, the power switch position is usually located in the lower right corner of the electronic scale, do not put the items on the weighing pan, and wait for the display screen to automatically clear to zero.
3. If the weight of the power just turned on is not zero, please wait for a while, or turn the power back on to make it zero.
4. Enter the unit price of the item, and place the product on the electronic scale to calculate**. <>