First of all, pay attention to the treatment and cleaning of the environment in which it is used.
A good clean environment and a more safe and reliable operating environment can make this ultrasonic cleaning equipment present a more stable operation effect, and the ultrasonic cleaning equipment with small profits and quick sales needs customers to clean the surrounding environment to avoid the influence of moisture factors on the internal precision instruments, only in this way can the ultrasonic cleaning equipment be in a safe and reliable operating environment, ensure better cleaning quality, and assist in the maintenance and maintenance of the surrounding environment to make the ultrasonic cleaning equipment have a better service life;
Secondly, pay attention to the use of suitable solvents and use reasonable methods to operate.
In order to ensure the good quality and stable operation effect of the ultrasonic cleaning equipment, it is necessary to use a suitable solvent for operation, with the help of the cavitation effect and functional mode of the ultrasonic cleaning equipment itself and the use of high-quality solvent as the basis, the operation of the ultrasonic cleaning equipment can be more enjoyable and have better quality, and the operation of the equipment can be avoided with the help of reasonable containers, so that the equipment can show stable operation and have a better service life;
-
Introduction: As a cleaning instrument, the ultrasonic cleaning machine needs to pay attention to many aspects when using, which is also a common feature of many machines, we can not decide which cleaning effect, or which power cleaning effect is the best, but we can decide which maintenance method is needed by the machine.
Routine maintenance and maintenance
1.Keeping the equipment workplace ventilated, dry and clean is conducive to the long-term efficient operation of the equipment and the optimization of working environmental conditions;
2.When the cleaning liquid is too dirty, it should be treated in time, and the dirt in the cleaning tank and liquid storage tank should be cleaned regularly to maintain the inside and appearance of the cleaning tank'Clean, which improves the durability of the washing tank;
3.Keep away from water vapor, corrosive gases and dust, and regularly clean up the attached dust with compressed air;
4.Regularly test the insulation performance of the equipment, regularly inspect the electrical components that are prone to aging, check the grounding wire, and ensure that the equipment is well grounded.
5.Regularly test the power supply to confirm that it meets the power supply voltage requirements of the equipment, and avoid long-term operation under unstable power supply that is too high or too low;
6.equipment with a filter device, with regular replacement of the filter element;
7.If there is a transmission mechanism, butter, oil and other lubricants should be added regularly as required, and the gear oil of the reducer should be replaced regularly to ensure that the moving parts work under good lubrication conditions;
Causes of faults and abnormal conditions and how to deal with them
1.Check whether the power supply and temperature controller settings are in the normal position without electric heating, check the relevant water level switch, and check whether the electric heater is invalid; replacement of failed components;
2.Poor insulation of live electric heating components in the shell or other component circuits, replace the poorly insulated components, and connect the grounding wire;
3.If the sound is abnormal, the cleaning effect is reduced, the ultrasonic generator or transducer is abnormal, check the insulation resistance of the two terminals of the transducer lead, and remove the transducer guard plate to check whether there is any abnormality;
4.The sound howling part of the transducer can not adapt to the change of cylinder and water level and water temperature, change the water level, and the action of the workpiece should not be too large when entering and exiting the water surface;
5.The fuse is burned out, and there is no blackening in the glass tube to check the power supply voltage, which may be caused by excessive power supply voltage or instantaneous change of load, replace the fuse of the same specification or a slightly larger fuse;
6.The fuse tube is burned, and the blackening overcurrent in the glass tube is caused, and the internal power tube or circuit may be short-circuited;
In general, ultrasonic cleaners are no different from other machines, but there are many problems that should not be ignored when using them, which are also worth paying attention to. Only by using the ultrasonic cleaner well can we ensure that the ultrasonic cleaner is used normally.
-
1. Key points of ultrasonic cleaner maintenance: It is forbidden to put conductive liquid from the air inlet at the top of the ultrasonic control cabinet, otherwise it will cause serious damage to the wiring system of the cleaning machine.
2. Pay attention to keep the ultrasonic cleaner clean, and turn off the power when not in use.
3. Do not collide or vibrate violently on the ultrasonic cleaner.
4. Keep the ultrasonic cleaner away from the heat source.
5. The machine should be avoided to be stored in a humid environment, which will easily lead to oxidation and rust of the equipment and moisture of the line after a long time.
6. The continuous working time of the ultrasonic cleaning machine should not exceed 4 hours, if the continuous working time is too long: the ultrasonic adjustment knob should be rotated to the 0 position, and the cooling fan should continue to work, and the ultrasonic cleaning will not be started to continuously dissipate heat in the ultrasonic control cabinet for at least 2 minutes.
7. After a long period of operation, the cleaning machine should first adjust the power balance car button to the zero position before shutting down, and use its fan to work for another 3-6 minutes and then shut down to ensure that the heat inside the power supply is dissipated.
8. The cleaning liquid after the cleaning of the Super Sail Rolling Sonic Cleaning Machine should be precipitated, filtered or replaced in time to ensure the cleaning effect.
9. Maintenance and maintenance is the most basic maintenance of a machine, if you want the machine to be used for a long time, you must maintain the machine, just like people need to eat, and the machine needs oil.
-
1.Put the cleaning objects gently into the cleaning basket of the ultrasonic cleaner, and then put the cleaning basket into the cleaning tank of the ultrasonic cleaning machine, and the objects cannot be put into the cleaning tank immediately to prevent the destruction of the machine and equipment and the actual effect of cleaning. 2.
According to different commodities or the actual effect of cleaning, pour cleaning liquid, water or cleaning organic solvent according to the proportion, and the water level in the ultrasonic cleaning machine shall not be less than a certain part. 3.The ultrasonic cleaner is connected to the switching power supply to ensure that the switching power supply is connected.
4.Turn on the ultrasonic cleaner button switch, and it shows that everything is working normally for the ultrasonic cleaner.
-
1.The ultrasonic cleaner turns on the power switch, and the indicator light does not light up.
Reason: aThe power switch is damaged and there is no power input;
b.The fuse ACFU blows.
2.When the ultrasonic cleaner turns on the power switch, the indicator light is on, but there is no ultrasonic output.
Reason: aThe connection plug between the transducer and the ultrasonic power board is loose;
b.fuse DCFU blowing;
c.Ultrasonic power generator failure;
d.Transducer failure.
3.Ultrasonic cleaner DC fuse DCFU fuse.
Reason: arectifier bridge stack or power tube burnout;
b.Transducer failure.
4.After the ultrasonic cleaner turns on the power switch, the machine has ultrasonic output, but the cleaning effect is not as ideal.
Reason: aImproper level of cleaning liquid in the cleaning tank;
b.Ultrasonic frequency coordination is not well adjusted;
c.The temperature of the liquid in the cleaning tank is too high;
d.Improper selection of cleaning solution.
-
If there is a problem with the ultrasonic cleaning machine, it is not recommended that individuals disassemble and repair it, so as not to cause secondary damage to the machine, the ultrasonic cleaning machine manufacturers will provide a one-year warranty and lifelong technical support.
-
Regular and reliable ultrasonic cleaning machines have a professional after-sales maintenance department, and you only need to contact the manufacturer to arrange after-sales problems for you, so you should choose a manufacturer with strong strength and good reputation when choosing.
-
Communicate with the manufacturer first, and see what the fault is, but it is recommended to hand it over to the manufacturer for repair!
Ultrasonic flaw detector is a portable industrial non-destructive testing instrument, which can quickly, conveniently, non-destructively and accurately detect, locate, evaluate and diagnose a variety of defects inside the workpiece. >>>More
Search for it"kminstrument"
Measurement function: valve leakage, hydraulic system leakage detection. >>>More
Hello! Mingyang ultrasound will answer for you:
The formula for ranging is expressed as: l=c t >>>More
Ultrasound also has certain harms on the human body. Therefore, it is recommended to spray with an aerosol can in a place where there are many cockroaches and let it sit for an hour. Or buy cockroach medicine. For other enquiries: 400 110 6119
There are three reasons why the screen frame of the ultrasonic vibrating screen always breaks is as follows: >>>More