There are two aspects to your question: heating and hot water.
Heating needs to consider the power size, you have to know your building type, thermal insulation status, floor height, window proportion, immersion air volume, orientation, etc., most of the calculations only look at 3, insulation + floor height + window proportion, to select the heating index of heat load per unit area. In general, 100w square meters of single-family heating is required for residential buildings, so 15kw is needed.
But you don't have to worry, in order to meet the needs of hot water, the power of the wall-hung boiler is far greater than that of heating.
Since you are household, then hot water is very good to say, like your case, as long as you meet the water consumption of all the people at one time, about 100L (40) for one person, calculated according to 5 people: 500L (40), washing basin 180L H (30), a total of 630L H, the heat load is:. This is all normative data, which is basically on the large side.
It is recommended that 25kW on the market is sufficient.
The wall-hung boiler works by switching the heating and hot water modes, that is, the heating and hot water are not used at the same time, as long as the high-power use is met.
-
The thermal power of the wall-hung boiler is divided into: 18kw, 20kw, 24kw, 28kw, 32kw, 36kw, not the bigger the choice, the better, but to choose the right power is the best, the right means that the fuel is more balanced
1. In the case of a house area of 80-120, the power of the wall-hung boiler is 18kw;
2. When the house area is 120-130, the selected power of the wall-hung boiler is 20kw;
3. When the house area is 120-180, the power of the wall-hung boiler is 24kw;
4. In the case of a house area of 180-220, the power of the wall-hung boiler is 28kw;
5. In the case of a house area of 220-260, the power of the wall-hung boiler is 32kw;
6. When the house area is 260-320, the power of the wall-hung boiler is 36kw;
-
The power of the wall-hung boiler is not as large as possible, and the size of the power should match the area of the house when installing the wall-hung boiler at home. If the power of the wall-hung boiler is too large, there will be problems.
The output power of the wall-hung boiler is generally considered according to the area of the room, the area where it is located, the temperature of the interior design, the insulation of the walls and windows, and the needs of the user.
According to the configuration of parts in the wall-hung boiler, it is a better way to determine the best choice of the wall-hung boiler. For example, imported parts from Europe, the highest quality is higher, good performance in all aspects, low failure rate, safety and so on.
-
Q: What is the maximum power of the wall-hung boiler?
A: The specific choices are as follows:
The gas wall-hung boiler has the dual functions of home heating and providing domestic hot water, and its thermal power is divided into: 18kw, 20kw, 24kw, 28kw, 32kw, 36kw
1. In the case of a house area of 80-120, the power of the wall-hung boiler is 18kw;
2. When the house area is 120-130, the selected power of the wall-hung boiler is 20kw;
3. When the house area is 120-180, the power of the wall-hung boiler is 24kw;
4. In the case of a house area of 180-220, the power of the wall-hung boiler is 28kw;
5. In the case of a house area of 220-260, the power of the wall-hung boiler is 32kw;
6. When the house area is 260-320, the power of the wall-hung boiler is 36kw;
-
The maximum power of the wall-hung boiler is 28kw. Wall-hung boiler is the abbreviation of gas wall-hung boiler, the full name is gas wall-hung heating furnace, which is a kind of water heater with natural gas as energy, with anti-freezing protection, anti-dry burning protection, accidental flameout protection, excessive temperature protection, water pump anti-jamming protection and other safety protection measures.
-
It is not that the greater the power, the better, because the greater the power, there are certain requirements for the wiring at home, and the temperature rises quickly, the thermal inertia is relatively large, and the fluctuation is relatively large.
-
The wall-hung boiler is definitely not as powerful as possible, too big will cause unstable water temperature, fast equipment loss, loud noise and so on. The power of the wall-hung boiler mainly depends on the size of the room. In addition, there are other factors, if the home is on the first floor or the top floor, it is easy to absorb some of the heat in a low temperature environment, then the power can be slightly larger.
If it is in a colder area, the power can also be slightly larger. The heating effect of the wall-hung boiler needs its own design and product quality, and it also needs to match the power and the house. My house is less than 100 square meters, using Viessmann condensing wall-hung boiler 18kw, high thermal efficiency, comfortable heating, and stable hot water.
You can go to [Selection Link] to determine the approximate power range.
-
No, the power of the wall-hung boiler must match your house. The larger the area, the more power and vice versa. In general, the output power is 18kW for up to 120 square meters, 24kW for 180 square meters, and 28KW for less than 220 square meters.
But also consider other conditions of the house, such as your hot water needs, weather conditions, floor of the house, underfloor heating or radiators, etc. The power matching is good, and if it is large, it will not only waste gas, but also cause the loss of the machine to outweigh the loss.
-
The power of the wall-hung boiler is not as great as possible. In fact, too much power has ***. For example, when the water temperature quickly reaches the water temperature of the heating setting, the wall-hung boiler will stop working, resulting in frequent start-up, which will affect the use of the machine.
In the same way, too much power can also cause unstable hot water temperature and unwanted noise. The power of the wall-hung boiler can be selected to match the conditions of your room, mainly depending on the area. You can consult at the time of purchase.
-
Please ask Rinnai wall-hung boiler and Dr. wall-hung boiler to buy which one is easy to use.
-
The gas wall-hung boiler has the dual functions of home heating and providing domestic hot water, and when choosing the power of the wall-hung boiler, it can be considered mainly from the two aspects of room type area and domestic hot water
1. In the case of a house area of 80-120, the power of the wall-hung boiler is 18kw;
2. When the house area is 120-130, the selected power of the wall-hung boiler is 20kw;
3. When the house area is 120-180, the power of the wall-hung boiler is 24kw;
4. In the case of a house area of 180-220, the power of the wall-hung boiler is 28kw;
5. In the case of a house area of 220-260, the power of the wall-hung boiler is 32kw;
6. When the house area is 260-320, the power of the wall-hung boiler is 36kw;
-
Q: I would like to ask what is the maximum power of the wall-hung boiler.
A: The details are as follows:
The gas wall-hung boiler has the dual functions of home heating and providing domestic hot water, and its thermal power is divided into: 18kw, 20kw, 24kw, 28kw, 32kw, 36kw
1. In the case of a house area of 80-120, the power of the wall-hung boiler is 18kw;
2. When the house area is 120-130, the selected power of the wall-hung boiler is 20kw;
3. When the house area is 120-180, the power of the wall-hung boiler is 24kw;
4. In the case of a house area of 180-220, the power of the wall-hung boiler is 28kw;
5. In the case of a house area of 220-260, the power of the wall-hung boiler is 32kw;
6. When the house area is 260-320, the power of the wall-hung boiler is 36kw;
-
Q: I would like to ask what is the maximum power of the wall-hung boiler.
A: The specific choices are as follows:
The gas wall-hung boiler has the dual functions of home heating and providing domestic hot water, and its thermal power is divided into: 18kw, 20kw, 24kw, 28kw, 32kw, 36kw
1. In the case of a house area of 80-120, the power of the wall-hung boiler is 18kw;
2. When the house area is 120-130, the selected power of the wall-hung boiler is 20kw;
3. When the house area is 120-180, the power of the wall-hung boiler is 24kw;
4. In the case of a house area of 180-220, the power of the wall-hung boiler is 28kw;
5. In the case of a house area of 220-260, the power of the wall-hung boiler is 32kw;
6. When the house area is 260-320, the power of the wall-hung boiler is 36kw;
-
The gas wall-hung boiler has the dual functions of home heating and providing domestic hot water, and when choosing the power of the wall-hung boiler, it can be considered mainly from the two aspects of room type area and domestic hot water
1. In the case of a house area of 80-120, the power of the wall-hung boiler is 18kw;
2. When the house area is 120-130, the selected power of the wall-hung boiler is 20kw;
3. When the house area is 120-180, the power of the wall-hung boiler is 24kw;
4. In the case of a house area of 180-220, the power of the wall-hung boiler is 28kw;
5. In the case of a house area of 220-260, the power of the wall-hung boiler is 32kw;
6. When the house area is 260-320, the power of the wall-hung boiler is 36kw;
-
You are talking about the lack of wall-hung boilers for gas bridges, if it is a larger one, choose a larger one, if you are specific, you can ask customer service, and the customer will give the most appropriate answer to Minhe according to our use area.
1. In the case of unprecedented prosperity in the domestic construction industry, the construction speed of the municipal heating pipe network is obviously unable to keep up. And the heating demand in the north is urgent. >>>More
The German Langlika is nice and worth recommending.
Household wall-mounted fresh fan purchase suggestions:
Wall-mounted household fresh air system is right to buy like this! The main points to consider in the purchase of new fans are the appearance, quality, filtration capacity, air volume, noise, installation location, etc., let's analyze them together. >>>More
Let's go play more Hearthstone forums Different classes have different priorities.