The most famous is Reykjavík, the capital of Iceland.
-
There are corresponding national standards for floor heating, and the "Indoor Air Quality Standards" stipulate that the indoor temperature for heating in winter is 16 degrees Celsius to 24 degrees Celsius.
Legal basis: Indoor Air Quality Standards
Article 5 The living room, bedroom, kitchen, toilet, corridor, bathroom, etc. should be kept between 17 and 27 degrees Celsius all year round.
Sixth, the indoor humidity is kept between 40 and 70 throughout the year;
-
Summary. Hello Floor Heating Acceptance Standards According to the relevant provisions of the People's Republic of China industry standard "Technical Regulations for Ground Radiant Heating" (JGJ 142-2004) on the part of low-temperature hot water radiant heating, the acceptance standards for floor heating construction are formulated as follows: 1. The general principles are to standardize the construction and acceptance of floor heating projects, so that the construction is advanced, safe and applicable, and to ensure the quality of construction, this standard is formulated.
This standard applies to the interior decoration and renovation of new industrial and civil buildings and residents. 2. Materials The materials of the low-temperature heating system should include heating pipes, water collectors and their connectors, and thermal insulation and radiation materials. The heating pipe must be a special pipe for geothermal heating.
The manifold must be a special manifold for geothermal pipes. The apparent density of the insulated benzene board is 20kg m3 and the thickness is 20mm. The flame retardant rating reaches fire protection class B2.
Aluminium foil, in non-woven high-gloss reflective foil. 3. The construction ground should be kept clean and smooth. Kitchens and bathrooms should be tested for waterproofing.
The ambient temperature of the construction is not lower than 5, and it is strictly forbidden to step on the heating pipe during the construction process.
The National Floor Heating Construction Code and Standard are the latest.
Hello Floor Heating Acceptance Standards According to the relevant provisions of the People's Republic of China industry standard "Technical Regulations for Ground Radiant Heating" (JGJ 142-2004) on the part of low-temperature hot water radiant heating, the acceptance standards for floor heating construction are formulated as follows: 1. The general principles are to standardize the construction and acceptance of floor heating projects, so that the construction is advanced, safe and applicable, and to ensure the quality of construction, this standard is formulated. This standard applies to the interior decoration and renovation of new industrial and civil buildings and residents.
2. Materials The materials of the low-temperature heating system should include heating pipes, water collectors and their connectors, and thermal insulation and radiation materials. The heating pipe must be a special pipe for geothermal heating. The manifold must be a special manifold for geothermal pipes.
The apparent density of the insulated benzene board is 20kg m3 and the thickness is 20mm. The flame retardant rating reaches fire protection class B2. Aluminium foil, in non-woven high-gloss reflective foil.
3. The construction ground should be kept clean and smooth. Kitchens and bathrooms should be tested for waterproofing. The ambient temperature of the construction is not lower than 5, and it is strictly forbidden to step on the heating pipe during the construction process.
Hello, I can only send a total of about a book, not so many words. <>
What is the pipe spacing.
I'll help find some.
Hello There are two kinds of 16 pipe diameter and 20 pipe diameter. The spacing of toilet pipes is between 10cm-12cm. The spacing between the bedrooms and living rooms is between 20cm-25cm.
The heat load is large, and the coil should be encrypted; The heat load is small and the tube spacing is large. In order to reduce air convection and exert the effect of floor heating. The national standard stipulates that the minimum spacing between floor heating pipes is 100mm, and the maximum is not more than 300mm; 25cm or 20cm for home use; 25-30cm for public areas.
The standard for the spacing of floor heating pipes is 200mm; The standard spacing between floor heating pipes in the bathroom is 150mm, and the spacing of floor heating pipes in the basement or storage room is 300mm.
-
Legal analysis: "Technical Regulations for Floor Radiant Heating" This is the only specification for floor heating in our country at present, which clarifies some key points and design and construction specifications for electric heating (heating cable floor heating system) and water heating (low temperature hot water floor heating system).
The national technical regulations for radiant heating stipulate that the floor heating is:
Low-temperature hot water ground radiant heating is what we often call water floor heating: it takes no more than 60 low-temperature hot water as the heat medium, heats the floor through the heating pipe in the buried floor, and evenly radiates heat to the room, which is a part of the microclimate of the room can be heated, and the low-temperature heating cable ground radiant heating is also commonly known as electric floor heating: electricity is used as the energy source, and the heating cable is the heating element, the electric energy is converted into heat energy, and the internal surface of the building is used as the heat dissipation surface, and the surrounding air is heated by convection heat exchangeIt also radiates heat transfer to the surrounding maintenance structures to ensure that the room temperature of the building meets the comfort requirements of the heating system.
This regulation is applicable to the design, construction and acceptance of ground radiant heating projects with hot water as the heat medium or heating cable as the heating element for new industrial and civil buildings.
Legal basis: Regulations of the People's Republic of China on Information Disclosure
Article 7: All levels of people shall actively promote information disclosure efforts, gradually increasing the content of information disclosure.
Article 8: All levels of people's ** shall strengthen the standardization, standardization, and informatization management of ** information resources, strengthen the establishment of ** information disclosure platforms, promote the integration of ** information disclosure platforms and government service platforms, and increase the level of handling ** information disclosure.
Article 9: Citizens, legal persons, and other organizations have the right to supervise administrative organs' information disclosure efforts, and to submit criticisms and suggestions.
-
Enforce the standard.
The Indoor Air Quality Standard (GB T 18883 2002) stipulates that the indoor temperature for heating in winter is between 16 degrees Celsius and 24 degrees Celsius.
A new type of floor heating - carbon crystal floor heating 23 degrees ecological floor heating has been recognized by the professional department as carbon crystal floor heating, and the carbon crystal electric heating plate is a heating element made of carbon crystal particles after special treatment after carbon fiber modification, and the carbon crystal particles are synthesized with special polymer resin materials.
-
There are national standards for floor heating, and the implementation standard is the "Indoor Air Quality Standard" (standard number: GB T 18883 2002), which stipulates that the indoor temperature of winter heating is 16 degrees Celsius to 24 degrees Celsius.
Indoor Air Quality Standards specify indoor air quality parameters and test methods. This standard is applicable to residential and office buildings, and other indoor environments can be implemented with reference to this standard.
The Indoor Air Quality Standard (GB T 18883 2002) stipulates that the indoor temperature for heating in winter is between 16 degrees Celsius and 24 degrees Celsius.
-
For the time being, there is no unified national standard, but the national standard for floor heating construction "Ground Radiant Heating Technical Regulations" has begun to be revised and ordered, if the floor heating pipe is too thin, it will cause uneven heat dissipation, and if it is too dense, it will cause invisible waste, so it is necessary to choose a regular floor heating construction unit, which is more professional.
For the time being, there is no unified national standard, but the national standard for floor heating construction "Ground Radiant Heating Technical Regulations" has begun to be revised and ordered, if the floor heating pipe is too thin, it will cause uneven heat dissipation, and if it is too dense, it will cause invisible waste, so it is necessary to choose a regular floor heating construction unit, which is more professional.
Ask a practical question, what is the length of a geothermal pipe for laying a node.
Answer: The length of each road is as close as possible, in the middle of 80---120 meters, the length is close to the temperature, if the length gap is large, the temperature gap will be large, and the valve needs to be adjusted to solve, if the length is more than 120 meters, the cycle is not good, it is not easy to heat. Generally, it is better to keep the branches at 100 meters.
Ask what is the length per square meter.
There is no experience point.
AnswerFirst of all, the floor heating should not be less than 50 meters per road, it is recommended that it is between 90 meters, not more than 120 meters, and it cannot exceed 15 square meters in each pipe. That's because floor heating uses the entire ground as a radiator, passing through the radiant layer of the floor heat medium, evenly heating the entire ground. The ground itself is used to store heat and radiate heat upwards for conduction, and then achieve the purpose of heating.
Hope it helps, dear
Asked whether the geothermal pipes can be heated in the middle, the developer reserved a few meters of the geothermal pipes of the caisson toilet, but there is no vent, what should I do?
Hope it helps, dear
-
For the time being, there has not been a unified national standard, but the national standard for floor heating construction "Ground Radiant Heating Technical Regulations" has begun to be revised, if the floor heating pipe is too thin, it will cause uneven heat dissipation, if it is too dense and will cause invisible waste, so it is necessary to choose a regular floor heating construction unit, which is more professional. Hope to adopt!
-
The pipe spacing and diameter are related to the heat storage of your room, and they are generally 15cm or 20cm
-
Generally, there is a national standard, such as the bulk density of the module.
Do you want to do underfloor heating?
-
Not yet, it's being written.
-
What you want to ask is what are the requirements of the aluminum film specification for floor heating pipes? There are material requirements, specification requirements, and installation requirements.
1. Material requirements: The material of the aluminum film of the floor heating tube should meet the relevant standards, and the common materials are high-performance PE film, PET film, nano silver flat, etc. It should have the characteristics of high temperature resistance, non-toxic, moisture-proof, mildew-proof, anti-static, anti-oxidation, corrosion resistance, etc.
2. Specifications: The thickness, width and length of the aluminum film and other parameters should meet the relevant specifications and standards. Generally speaking, the thickness of the aluminum film of the floor heating pipe is above, the width is between 600mm-1500mm, and the length can be cut on demand.
3. Installation requirements: The aluminum film of the floor heating Zhiye pipe should be laid and installed in accordance with the relevant requirements. Generally, it is necessary to ensure that the aluminum film is in good contact with the ground to avoid bubbles and wrinkles, so as to ensure the smooth heat transfer and thermal effect of floor heating.
The standards and requirements of aluminum film for floor heating pipes are sometimes updated and improved with the changes in factors such as technical improvement, industry standard spine localization and market demand, so when laying and using aluminum film for floor heating pipes, it is also necessary to consult the opinions and suggestions of professionals according to the actual situation, and do a good job in standardizing construction and maintenance management.
-
The corresponding national standards for floor heating include JGJ142-2012 [Technical Regulations for Ground Radiant Heating and Cooling], CECS424:2016 Technical Regulations for Thin Dry Floor Heating of Prefabricated Trench Insulation Modules, etc.
The selection criteria for floor heating are: [Floor Radiant Heating Construction Atlas] 12K404.
Floor heating is divided into wet floor heating and dry floor heating two technologies, wet floor heating with insulation board concrete backfill wet construction, suitable for high entry threshold, need a long time of floor heating occasions; Dry construction of prefabricated trench insulation floor heating module for dry floor heating is suitable for intermittent heating occasions with low threshold design, high heating temperature and energy saving.
Floor Heating Standard Construction Drawing Set 12K404
Floor heating national standard JGJ142
CECS, the industry standard for dry underfloor heating
Comparison of wet underfloor heating and dry underfloor heating construction technology.
-
The national standard for floor heating has not yet come out, and there are industry standards to refer to'
-
The new industry standard "Technical Regulations for Radiant Heating and Cooling" (No. JGJ 142-2012) came into effect on June 1, 2013.
-
What is the spacing between the floor heating pipes.
I regret buying hobar electric heating film, and the reviews on JD.com are all fake. I looked at the praise and bought four rooms of electric heating film, spent more than 7,000, the electric heating film under the tile shop tripped as soon as it was powered, which was caused by the unqualified product. When you buy, the merchant does not tell you that there will be a problem with the tiles, and there is a problem after the paving, and the empty opening is small, so that you can change the big one, change it or trip, and let you remove the leakage protection, which will cause a lot of safety hazards. >>>More
First of all, soak the feet to soften the keratin, and then put the feet into the foot mask, and fix it with tape, wait for 60 minutes, and after 60 minutes, you can take off the foot mask, generally after 3-10 days of use, it will begin to peel, the peeling may be large, small, broken or powdery, usually 2-3 weeks dead skin can be completely peeled off, after the stratum corneum is all off, you can apply body lotion or moisturizer for follow-up care. >>>More