-
a : thank you for your help.(Thank you very much for your help).
b: that is all right , don't mention it (Nothing, no thanks).
-
That is all right It's okay, it's okay.
don't mention it is a trivial matter, no thanks!
These two phrases mean different things.
-
Add this symbol on it - and this will meet your requirements for a dash.
-
This should be a font problem, and I chose a Chinese font that AE cannot support [there is no universal ASCII encoding. ASCII (American Standard Code for Information Interchange**) is a computer coding system based on the Latin alphabet for the display of modern English and other Western European languages. It is the most versatile single-byte encoding system available today and is equivalent to the international standard ISO IEC 646.
This prompt will appear, and you can't turn off this prompt to switch to other fonts. It can only end the AE process completely. Because I also encountered such a problem, that is, this problem occurs when switching the font to the "classic traditional book" font.
In the face of this pop-up window that can't be turned off, can we only force close the AE process?
After a few explorations, I found a clever way to do this, which is to keep pressing the ESC+DELETE button! (Note that the Windows keyboard is a delete key!!) It's not a backspace key! )
Because the ESC button is equivalent to clicking OK, and the delete button is equivalent to deleting the wrong text layer at the moment the pop-up window is closed, which requires many quick and uninterrupted operations to succeed!
After hundreds of clicks, the pop-up window is finally gone! At this time, don't do ctrl+z to undo, otherwise continue to press hundreds of times!
Of course, the text layer has also been removed, but this is much stronger than forcibly closing AE, a text layer is nothing! At least you can continue to save the AE project file!
The detailed explanation of this issue is as follows:
83 ::2 Error message message message message message
ct generic: bad lendesignvector error message stating that the operation on a vector graphic asset failed.
Possible cause of the error: Confirmed by a member of the development team, the error is related to font handling. As we can imagine, it involves B-Spline Bézier Curves, which describe the outlines of the font, or B-spline Bézier curves, and how to interpret them as the actual font we see.
In many cases, the error is caused simply by corrupted text, such as an unclosed font outline, or a duplicate anchor point. Suggested workaround: Remove all non-system default fonts from the font management panel of the operating system you are using, and then launch the program to confirm that everything is back to normal.
Then add the other fonts you need step by step, until you find out which font is playing tricks, find it, and delete it.
-
I saw it from another online and I had a file like this. I deleted all the classic books, anyway, the classic fonts, and the files can be opened.
-
To reinstall AE, you need to uninstall and clean it up completely, and then reinstall it or just install a higher version.
-
Press ESC first, wait for the prompt to disappear, and then close AE, because the font coding above the CC2014 version is not very perfect, it is recommended to replace the CC2014 version, which can solve the appeal problem.
-
It seems that the English font will be switched to the traditional font type.,Except for pressing esc and enter.,It seems that there is no other way but to force it to end.。
-
Keep pressing esc for about 1 minute and the window is gone perfectly solved.
-
CIO is the input/output register area, A is the special register, T is the time, H is the hold, and W is the internal auxiliary.
There are three precautions when programming PLC.
1. Dual-coil output.
If the coil of the same element is used two or more times in the same program, it is called a dual-coil output. For output relays, at the end of the scan cycle, what is really output is the state of the last y0 coil.
2. Optimal design of the program.
When designing a parallel circuit, the branch of a single contact should be placed underneath; When designing a series circuit, a single contact should be placed on the right, otherwise an extra command will be used.
3. The position of the programming element.
Output components (e.g. OUT, MC, SET, RST, PLS, PLF, and most application instructions) should be placed on the far right of the ladder and cannot be directly connected to the left busbar. Some commands (e.g. END and MCR) cannot be actuated by contacts and must be connected directly to the left or temporary bus.
Four features of PLC:
1. Feature-rich.
PLC is very feature-rich. This is mainly related to its command system with rich processing information and internal devices that store information.
It has dozens or hundreds of instructions, which can be used to deal with various logical problems and perform various types of data operations. Whatever a normal computer can do, it can do.
2. Easy to use.
It is very convenient to control the system with PLC. This is because: first of all, the establishment of PLC control logic is a program, and the program is used to replace the hardware wiring. Programming is much more convenient than wiring, and changing programs is much more convenient than changing wiring!
Secondly, the hardware of the PLC is highly integrated and has been integrated into various miniaturized modules. Moreover, these modules are matched, and have been serialized and standardized. The modules required for various control systems are mostly available in stock by PLC manufacturers, and they can be purchased on the market.
Therefore, the configuration and construction of the hardware system is also very convenient.
3.Easy programming: Although there are no actual relays, time relays, or counters in the PLC, these devices actually exist through programs (software) and system memory. The sheer number of them is unimaginable for relay control systems.
Even for small PLCs, there are thousands of internal relays, and hundreds of time relays and counts. Moreover, the contacts of these relays can be used an unlimited number of times. There are so many internal logic devices in PLC that users don't feel any limitations when using them.
4.Maintenance is also very convenient. This is because PLCs are equipped with a lot of fault warning signals, such as the battery voltage of the PLC to support memory retention data is insufficient, and there is a corresponding low voltage signal indication.
Moreover, the PLC itself can be used to record fault conditions. Therefore, if the PLC is faulty, it is easy to diagnose.
-
Hello, first make sure there is no problem with the operation.
The first is the easiest to make is that you have opened the converted dwg file in CAD, and you find that it is wrong and want to re-convert, at this time because the original dwg file has been opened, so there will be a program exception!
Second, you saved the T-graph final format file name without saving it.
Third, look at the target error file for something that is missing from the root directory, or an error that occurred when updating to a new version because the version is not very stable.
Method: It is recommended to copy this part here from the same software!
Eat, treat, be invited, appreciate face, give face,
Communication skills: how we can avoid ineffective communication in our daily lives.
Ergonomics is a very important criterion in interior design, which is equivalent to a "ruler". >>>More
There are many, the plane is from a dragonfly, the radar is from a bat, the mouse is from a mouse, and the saw from the thatch, now I can't think of it for the time being.
Thirty-six strategies, also known as thirty-six strategies, refers to the ancient Chinese thirty-six art of war strategies in war and confrontation is very practical, substitute into the game of eating chicken can also wish you a helping hand "to win with wisdom", besiege Wei to save Zhao, this refers to besieging the capital of Wei to rescue Zhao. It is now borrowed to refer to the tactic of overtaking the enemy's rear to force it to withdraw. In the fourth row, if our side is in a fierce battle, we can let our teammates cover us with gunfire, so that we can break through to the rear of the enemy and kill the enemy, especially under the hill to attack the hillside, the terrain is not conducive to us, and it is easy to fall into a disadvantage if we force our side to attack, and after the sudden attack, we must not be seen to enter from the rear, and take him by surprise.