The TOLEDO scale start-up prompt "no stable weight" usually indicates that the weight of the scale is unstable, which may be caused by the following reasons:
1.Check the mechanical and electrical parts: Check whether the mechanical and electrical parts of the electronic scale are normal, including sensors, weighing pans, power supplies, etc. If a part is found to be damaged or loose, it needs to be repaired or replaced.
2.Clearing the scale: Remove the weights from the scale, and then perform the clearing operation. After clearing, re-run the weighing test, if the display is normal, it means that the problem has been solved.
3.Adjust the boot reset range: If the problem persists after clearing zero, you can try to adjust the boot reset range. For specific operations, you can refer to the instruction manual of the electronic scale or contact the electronic scale manufacturer for consultation.
Please note that the above steps may require some technical knowledge and experience, and it is advisable to seek professional help if you are unsure how to do it.
-
This is adjusted down to the boot zero range! To put it simply, you take off the weighing pan and turn it on, if it can be reset to zero, just turn it down 100% and turn it on to zero!
-
Hello, dear users, the fault cannot be reset to zero when booted, and you need to contact the **Commercial Metrology Bureau Standard Weight Recalibration or hardware maintenance.
If you still have questions, please feel free to ask the company.
-
I found these contents in the manual, but I didn't say how to deal with them.
-
This literally means that there is no stable scale.
If this is displayed after powering on, it should be zero drift, or there is a problem with the mechanical or electrical parts of the scale, such as the sensor......Check the mechanical and electrical parts, troubleshoot the problem, and then clear it should be fine......If that doesn't work, you'll have to recalibrate.
-
Depending on what type of scale it is, it is generally a separate screw at the bottom, or you want to open the outer shell, on the motherboard.
-
Recalibration, or changing the sensor, is operated by someone who knows how to do it, which is more troublesome.
-
Toledo electronic scale boot shows what is the reason for nostableweght.
-
The zero position of the electronic scale is out of range! Now this situation can be solved by recalibrating.
-
Hello, dear users, this display means that the scale cannot find the zero point, please remove the weight on the scale or recalibrate the zero point. If this is not possible, please contact the company's services** on 4008 878 788
If you still have questions, please feel free to ask the company.
-
Recalibrating is all you need to go!
-
Hello, dear users, there are many models of our electronic scales, and the country** settings of each scale are different. Please let me know the specific device model, thank you.
If you still have questions, please feel free to ask the company.
-
The battery is dead, let's replace the battery.
1. First prepare the rubber pad.
2. Then reset the data in the electronic scale to zero. >>>More
360 Q&A.
What are the brands of electronic scales? >>>More
Electronic scales have a special button to adjust the number of digits. >>>More
Electronic scales, how to use electronic pricing scales, it will be very simple at a glance.
It is necessary to determine whether there is a problem with the contact of the scale battery, if there is a problem with the contact, it will cause the scale to display inaccurately. When the battery of the electronic scale is out of power, there will be a prompt "lo", remember to replace the battery in time. >>>More