The problem of disassembling and assembling the air conditioner unit, how to disassemble the air con

Updated on home 2024-04-15
9 answers
  1. Anonymous users2024-02-07

    The disassembly and assembly of the air conditioner is a more professional problem, if it leads to the leakage of refrigerant (that is, the refrigerant you said), it cannot be used normally if it is installed again! It's best to find a professional.

    But I can tell you a little bit about the steps:

    1. Turn on the air conditioner and adjust it to refrigeration.

    2. Close the valve of the external unit.

    3. Shut down, dismantle the pipeline from the internal and external machines. (It's easy to say).

    If you have to operate it yourself, the first one is to disconnect the power supply, then tighten the hexagon clockwise (both upper and lower), unscrew the pipe, and it is normal for a small amount of refrigerant to leak (estimated 2-3 seconds) and it will not leak! Seal the pipe mouth with tape and can't go into the soil! Unscrew the power cord (use paper and pen to make a record and then take a picture with your mobile phone, or you won't press it), and the outside is finished!

    After carrying it away, straighten the pipe (this slow point is easy to break) and pull it home with the internal machine! The inner machine is also dismantled!

    Finally, I advise you to find a professional!

  2. Anonymous users2024-02-06

    It's okay, the fluorine is collected, just don't leak.

  3. Anonymous users2024-02-05

    You turn off the small tube first, and then turn off the thick tube when the sound of the air conditioner compressor is muffled.

  4. Anonymous users2024-02-04

    Did you collect fluoride when disassembling the machine? If you collect it, install the indoor and outdoor units, connect the pipes, tighten the high-pressure pipe, don't tighten the low-pressure pipe first, open the high-pressure angle valve, tighten the low-pressure pipe joint when venting for a few seconds, and then open the low-pressure angle valve. If the fluorine is confiscated, it is troublesome, and it is necessary to install the internal and external units before emptying and filling the fluorine.

  5. Anonymous users2024-02-03

    The dismantling method of the air search liquid xiang external machine is as follows:

    1. Before disassembling the air conditioner, the refrigerant should first be received into the unit, and the refrigeration mode of the air conditioner should be turned on at the same time, and it should be run for a period of time.

    2. Then open the valve in the outdoor unit, and close the high-pressure valve with a wrench, at this time the air conditioner is still running, so as to avoid the refrigerant passing through the high-pressure valve, so that it will be compressed into the outdoor unit.

    3. It only takes about three minutes to run, and the air conditioner is not refrigerated, which means that it has all been received into the outdoor unit, and finally we bury the three-way valve and close the door.

    4. Next, remove the connecting pipe of the indoor unit and the outdoor unit, and remove the cable of the outdoor unit, so that the entire outdoor unit can be removed together.

    What problems need to be paid attention to when installing an air conditioner?

    1. The location chosen for the installation of the air conditioner is very important, and it must be noted that if it is tilted, the condensate inside may leak out from the indoor unit, resulting in the lack of freon, which will affect the effect of refrigeration or heating.

    2. It is best to choose the direction of the back sun for the location of the outdoor unit, because if the sun is exposed to the sun for a long time, it will also lead to poor heat dissipation function, and the refrigeration effect of the air conditioner will be greatly reduced.

    3. The outdoor unit needs to be installed with an iron frame, and it is necessary to pay attention to the load-bearing capacity of the air conditioner. For example, some people will install the air conditioner on the balcony, so it is not easy to fall risk.

    4. Some people like to cover the air conditioner with a dust cover, which is too much to do, because the air conditioner needs to dissipate heat when it is running, and if there is a dust cover, the heat dissipation effect will become very slow, resulting in the outdoor unit being easily damaged.

  6. Anonymous users2024-02-02

    The commonly used tools at home can loosen the fixing nuts of the air conditioner and the external machine fixing frame, and the external unit can be removed, but the disassembled air conditioning outdoor unit also involves other professional problems such as refrigerants.

    1. Tools needed: large wrench, movable wrench, hex wrench, Phillips screwdriver.

    2. **Freon. Before disassembling the air conditioner, turn on the air conditioner and set it to refrigeration mode, wait for the compressor to run for about 5 minutes-10 minutes, and after the refrigeration state returns to normal, unscrew the protective cap of the liquid pipe and gas pipe connection port of the external unit. After closing the valve of the high-pressure pipe, wait for about a minute for dew to condense on the outer surface of the pipe, you need to close the low-pressure pipe valve immediately, and quickly turn off the air conditioner, unplug the power switch, tighten the safety cap with a wrench, and the operation of fluoro-oxygen is completed.

    3. Unscrew the nut connected to the outdoor unit and the fixing screw of the foot of the outdoor unit, and the outdoor unit of the air conditioner can be removed from the fixing frame. Straighten the connecting pipe of the outdoor unit of the air conditioner to prevent dust and water from entering the pipe, and fix it with a fixed rope after coiling.

    4. The disassembled air conditioner should be placed in a carton with an anti-collision protective layer to avoid damage to the air conditioner during the collision.

    If you want to disassemble the air conditioner at high altitude, it is best to cooperate with two people. Be sure to wear a helmet, a safety rope and a safety buckle that are specially removed from the air conditioner. The safety rope should be fixed in a safe and firm place to protect your personal safety.

  7. Anonymous users2024-02-01

    How to disassemble and assemble the air conditioner unitHello dear, how to remove the air conditioner outside the unit1, before disassembling the air conditioner, it is generally necessary to put away the freon inside the air conditioner. The thin pipe on the air conditioner is generally connected with the high-pressure valve, while the thick pipe on the air conditioner is generally connected with the low-pressure valve. 2. Use a movable wrench to remove the cover of the high-pressure valve and the low-pressure valve, and then use an Allen wrench to tighten the nut inside the high-pressure valve.

    If you disassemble the air conditioner in winter, you also need to use a screwdriver and other disassembly tools to open the metal back cover of the air conditioner, and then find the temperature control probe inside the air conditioner, and soak the temperature control probe in hot water to avoid the temperature control probe from being frozen. If you want to disassemble the air conditioner in the summer, you can skip this step. 3. Then you should use the remote control to set the temperature of the air conditioner unit lower, so that the air conditioner compressor can speed up the operation.

    Wait for about two minutes, then use an Allen wrench to tighten the nut inside the low-pressure valve on the air conditioner, so that the freon can be received into the air conditioner. 4. When the freon is collected, the sealing lids of the high-pressure valve and the low-pressure valve should be installed back. Then you should also use the remote control to turn off the internal unit of the air conditioner, and also unplug the power plug of the macro bucket of the air conditioner, and then you can start to disassemble the external unit of the air conditioner.

    Hope it helps! If my answer is helpful to you, please give a thumbs up (in the lower left corner), I look forward to your like, your efforts are very important to me, and your support is also the motivation for my progress. Finally, I wish you good health and a happy mood again!

  8. Anonymous users2024-01-31

    1. First of all, open the top cover of the air conditioner. The top cover is a snap link, which can be opened by pulling it outward.

    2. Then find the screws at the air outlet and around the air conditioner shell, and unscrew them.

    3. After screwing the screws, find the buckle on the upper part of the air conditioner (Zhaohui learned that the buckle link is tight, and you need to help remove the buckle). When the slave is opened, the shell can be completely peeled off.

  9. Anonymous users2024-01-30

    Dear, hello, I am happy to answer for you: how to disassemble the outdoor unit of the air conditioner Answer: Dear, unscrew the nut connected to the outdoor unit, and screw the prepared sealing sodium to protect the silk pattern of the connecting joint of the outdoor unit.

    Loosen the fixing screws on the foot of the outdoor unit. It is recommended to use a rope to hang it for safety* when disassembling the outdoor unit. Straighten the pipes of the outdoor air conditioner and block the four ports of the connecting pipes to prevent dust and moisture from entering the air.

    After that, tie it in a plastic bag and plate it. When disassembling the air conditioner, the refrigerant in the air conditioner must be collected into the outdoor unit, start the air conditioner before dismantling, set it to the refrigeration state, wait until the compressor runs for 5-10 minutes, and the refrigeration state is normal, and unscrew the cap on the interface between the liquid pipe and the gas pipe of the external unit. After that, close the shut-off valve of the high-pressure pipe (fine), and after one minute, the surface of the pipe is condensed, and the shut-off valve of the low-pressure pipe (coarse) is closed immediately.

    Quickly turn off the air conditioner, then unplug the power plug and use a wrench to tighten the safety cap, so that the refrigerant job is done.

Related questions
23 answers2024-04-15

The disassembly of the external unit of the air conditioner is to first compress the refrigerant**, use a tool to disassemble the connecting copper pipe and power cord with the internal unit, and then remove the fastening screws of the base and the support frame. >>>More

4 answers2024-04-15

See if it's one of the following reasons:

1.When the air conditioner is started or stopped, it is normal for the plastic parts of the internal unit to make a sound due to the expansion and contraction of the internal unit due to temperature changes. There are also some pipelines that are deformed due to thermal expansion and contraction, and are attached to the compressor or metal shell, causing resonance. >>>More

8 answers2024-04-15

This is not normal. 1.When the air conditioner outside is always on, you first have to consider whether the air conditioner at home is inverter or fixed-frequency. >>>More

6 answers2024-04-15

1.If the installation stability of the indoor unit is not good, when the outdoor unit of the air conditioner is running, the copper pipe is connected to the indoor unit. If the indoor unit is not stable enough, it will be affected by the compressor, resulting in the resonance of the indoor unit. >>>More

7 answers2024-04-15

The outdoor unit of the air conditioner always stops suddenly, and the advantages of inverter air conditioning are reflected in this situation.