When the ambient temperature is too high, the sun is direct and there is no shading object, the outdoor unit has poor ventilation and a mesh cover or the wall is blocked in front of the outdoor unit, the air conditioning heat cannot be blown out, and the temperature is too high, the compressor will automatically start the protection and stop working to avoid damage to the compressor.
Analysis of other reasons for non-work:
1.The reason why the outdoor unit of the air conditioner is not working - the remote control mode is incorrect.
Check whether the remote control is set to refrigeration mode. Using the remote control of the air conditioner, adjust the mode to display "cooling" or "snowflake", and set the temperature to 26 degrees Celsius or below.
2.The reason why the outdoor unit of the air conditioner is not working - power supply problems.
Pay attention to whether the outdoor unit has working sound (including outdoor unit, fan and compressor). If the outdoor unit fan is running, the control circuit is basically normal. At this time, you should observe whether the compressor starts or not, and if the compressor does not start, you should check whether the power supply is normal.
3.The reason why the outdoor unit of the air conditioner does not work - the reason for the voltage.
If the air conditioner can't be turned on, it is necessary to check whether the external power supply is electric or whether the voltage reaches the rated voltage. If it is not the cause of low voltage, please check whether the indoor and outdoor units are connected correctly, whether the wires are aging, and whether the motherboard of the indoor unit is wired correctly, otherwise replace the motherboard of the internal unit.
4.The reason why the outdoor unit of the air conditioner does not work - it is not maintained for a long time.
The analysis of the reasons why the outdoor unit of the air conditioner does not rotate for a long time may be loose in terms of structure, which may be the loosening of the locking part of the screw and the wind wheel; The flat position of the motor and the mating part of the wind wheel are not in the proper position; Due to the problems of injection molding process assurance, the plastic parts have a squeaky sound, the air guide strip and the connecting rod mechanism belong to plastic parts, and the transmission performance of the structure of the air guide strip, stepper motor and connecting rod mechanism is affected, which will also cause the indoor unit to not run.
-
470711500 is right, the general household air conditioner is not sensitive to sun exposure, except for a little electricity, will not cause failure.
-
Use a parasol and find a way to cool down the outdoor unit.
-
It is recommended to repair it in time.
It may be that the fan capacitor is bad or there is a lack of fluorine or the radiator is too dirty.
-
The outdoor unit of the air conditioner does not work for reason 1:
When checking the cause of the outdoor unit of the air conditioner not rotating, it is first necessary to check whether the heat dissipation effect of the air conditioner's condenser is good, if the heat dissipation effect of the air conditioner condenser is poor, it will lead to overheating protection of the air conditioner compressor.
Solution: When encountering such a situation, the user should first clean and maintain the air conditioning condenser in time to ensure the heat dissipation effect of the air conditioning condenser, and at the same time, the user also needs to clean the air conditioner regularly, so as to effectively extend the service life of the air conditioner.
Reason 2 for the outdoor unit of the air conditioner not working:
Whether the circuit of the air conditioner is broken, after the circuit of the air conditioner fails, it will also cause the outdoor unit of the air conditioner to not rotate. Therefore, when the outdoor unit of the air conditioner does not rotate, it is also necessary to check whether there is a problem with the circuit of the air conditioner.
Solution: When there is a problem with the circuit opening of the outdoor unit of the air conditioner, the user needs to check the air conditioning circuit one by one, check which line has the problem, and eliminate it in time.
The outdoor unit of the air conditioner does not work for three reasons
When the connection between the indoor unit and the outdoor unit is broken or damaged, the outdoor unit of the air conditioner will not work properly.
Solution: When there is a problem with the connection line of the indoor unit of the outdoor unit, it is also necessary to check and eliminate the air conditioning line to detect which line of the air conditioner has a problem, and then it can be better repaired.
The outdoor unit of the air conditioner does not work for four reasons
When the components of the air conditioner are damaged, it will also cause the outdoor unit of the air conditioner to not work. When the starting capacitor of the air conditioner compressor and the compressor are damaged, the outdoor unit of the air conditioner will not rotate, and when the fan of the outdoor unit of the air conditioner is damaged, it will also cause the outdoor unit of the air conditioner to not rotate.
Solution: When the capacitance of the air conditioner compressor is damaged or the air conditioner compressor is damaged, the outdoor unit of the air conditioner cannot work normally, the air conditioner compressor needs to be repaired or replaced. When the fan of the outdoor unit of the air conditioner is damaged, the fan of the outdoor unit needs to be replaced to ensure the normal operation of the outdoor unit of the air conditioner.
The outdoor unit of the air conditioner plays a very large role in the process of air conditioning refrigeration and heating, so when the air conditioner is maintained, the user should also maintain and clean the outdoor unit of the air conditioner in time, so as to ensure that the air conditioner can run well and normally.
-
The fan of the air conditioner outside unit mainly plays the role of heat dissipation, and the air conditioner fan does not rotate will affect the heat dissipation effect of the air conditioner
1. The main control switch has poor contact.
Use a multimeter to measure the contact resistance of the main control switch, when the resistance is too large or zero, it should be repaired or replaced.
2. The fan motor of the air conditioner is damaged.
If the fan motor of the air conditioner is damaged, just replace the fan motor.
3. The capacitor of the starting fan is damaged.
The capacitor needs to be inspected and then repaired or replaced with a capacitor of the same specification by a professional service person.
4. The fan motor coil is damaged.
Use a multimeter to measure the contact resistance of the main control switch, when the resistance is too large or zero, it should be repaired or replaced, but in general, it is directly selected to be replaced.
5. The motor of the fan is tightly fixed with the fan blade.
If the screw is loose, the solution is to re-tighten the set screw.
6. The power supply voltage is low.
The low power supply voltage causes the compressor to not operate normally, and a voltage regulator is required.
7. The compressor is damaged.
If the compressor is damaged, the solution is to replace the compressor.
-
The reasons why the air conditioner does not turn on the outside unit are: 1. The indoor temperature has reached the set temperature. Zen Orange Cave 2, the contactor of the control compressor and the heat dissipation fan Wu Wei was damaged.
1. If the temperature set by the air conditioner is the same as the outdoor temperature, you only need to adjust the temperature of the air conditioner. 2. If it is a problem caused by all the damage of the components, you can find professionals to come to the door for inspection and maintenance.
-
What is the reason why the air conditioner does not turn at a high temperature, 1. It is normal for the intermittent to stop, and it is unusual to keep it from turning. 2. When the air conditioning heating mode is running, the heat exchanger of the outdoor unit is used as an evaporator, that is, the low-temperature and low-pressure liquid refrigerant after throttling and depressurizing in the air-conditioning system absorbs heat from the surrounding air in the heat exchanger of the outdoor unit and vaporizes into a gaseous state. When the outdoor ambient temperature is high, such as above 15 degrees, if the outdoor fan motor is running all the time, it will lead to excessive evaporation of the evaporator in the heat exchanger of the outdoor unit, and the superheat of the refrigerant at the outlet of the heat exchanger is too large, so that the compressor has too high exhaust temperature protection.
When the outdoor ambient temperature is low, the outdoor fan motor must run continuously in the heating operation process of the air conditioner. 3. If the fan motor of the outdoor unit of the air conditioner is running intermittently and the heating effect of the air conditioner is normal, it can be ignored; If the fan motor of the outdoor unit does not run from beginning to end or the heating effect of the air conditioner is obviously abnormal, it should be reported to the air conditioning manufacturer for after-sales repair, and the maintenance personnel will be repaired on site. Hope it helps.
-
Air conditioning has become an indispensable household appliance in our lives, especially in the hot summer, if there is an air conditioner around, then it must be very happy. Since it is a household appliance, there may be various failures, and the common failures of air conditioners are water leakage, non-refrigeration, outdoor unit failure, etc. Therefore, in the process of using the air conditioner, we must strictly follow the instructions for use, improper operation is likely to cause damage to the air conditioner.
3. Condenser failure. The condenser of the air conditioner is the most important component that produces cold and warm air, if the condenser of the air conditioner is not cleaned for many years, it is easy to fail, and if the condenser fails, the system will automatically start self-protection, and the fan will automatically stop running.
What are the other reasons why the fan of the outdoor unit of the air conditioner does not turn?
-
1. If the air conditioner is a fixed-speed air conditioner, the fan of the air conditioner does not rotate, which is a very normal phenomenon, the air conditioner is working, when the indoor temperature reaches the standard temperature you set, it will automatically stop working, and after the indoor temperature rises, the phenomenon of the fan of the air conditioner will disappear by itself.
2. The fan of the outdoor unit of the air conditioner does not rotate may also be due to other reasons for the following failures:
1. The fan motor of the air conditioner is damaged.
Solution: Since the fan of the air conditioner does not rotate caused by the damage of the motor, then you only need to replace the fan motor, and the problem of the fan of the air conditioner fan not turning is solved.
2. The capacitor of the starting fan is damaged.
Solution: If the air conditioner fan does not rotate due to the broken capacitor, it will be a bit troublesome, and you need to contact professional maintenance personnel for maintenance, and the capacitor will be replaced under normal circumstances.
3. The bearing of the fan is stuck by a foreign object or the bearing is loose.
Solution: At this time, you only need to figure out what causes the fan of the air conditioner to not rotate, if it is caused by foreign objects, just clean the bearing, if it is loose, adjust it and solve it immediately.
4. The bearing of the fan lacks lubricating oil.
Solution: The phenomenon that the fan of the air conditioner does not rotate caused by this fault is actually due to the fact that the air conditioner has been used for too long, but it is also very easy to solve, we only need to make up some oil on the bearing.
5. The compressor is damaged.
Solution: The fan of the air conditioner caused by the compressor does not rotate, once the compressor is broken, not only the outdoor fan of the air conditioner does not turn, but the refrigerant cannot be cold, in fact, at this time, the compressor only needs to be replaced, and the air conditioner can continue to work normally.
5. The power supply voltage is low.
Solution: If the general compressor wants to work normally, it usually needs the power supply voltage to reach 187 V to 243 V, if it is less than this number range, the compressor can not operate normally, at this time, it is necessary to configure a voltage regulator for it at home, this problem can be effectively solved.
-
As the saying goes, "cold in Sanjiu, hot in Sanfu", as a weapon for refrigeration and cooling, air conditioning has always played a pivotal role in people's lives, especially becoming an indispensable household appliance in summer, but because of various failures, the problem that air conditioning and even household air conditioning can not operate normally has also followed, and the air conditioner does not turn is one of its main faults. There are many reasons why the air conditioner does not turn, what to do if the air conditioner does not turn, pay attention to the following solutions.
What is the matter with the air conditioner outside not turning - the control transformer is damaged.
What to do if the air conditioner does not rotate: remove the transformer, measure the non-resistance value of the primary coil, the secondary resistance value is normal, obviously, the primary coil of the transformer has been damaged, after replacing a new transformer, connect the power supply, the power indicator light is on, and the machine is working normally.
What is the reason that the air conditioner does not rotate - the varistor breakdown is damaged.
What to do if the air conditioner does not rotate: open the shell of the machine to detect, and find that the 5A fuse has been blackened, which is mostly caused by lightning strikes, here, Comfort 100 reminds customers that in the summer when thunderstorms occur, it is best to unplug the power supply of the air conditioner when the weather changes, so that unnecessary losses can be avoided.
What is the reason why the outside unit of the air conditioner does not turn - the outside of the condenser and evaporator is dirty.
What to do if the air conditioner does not rotate: the evaporator and condenser of the air conditioner are dirty and blocked (such as catkins and dust), which will make the refrigeration effect significantly reduced, and even the phenomenon of non-refrigeration.
What is the reason why the outside unit of the air conditioner does not turn - damage to the starting capacitor of the compressor.
What to do if the air conditioner does not rotate: if a split air conditioner, no refrigeration after starting, indoor and outdoor fans are rotating, but the compressor is not working, turn on the outdoor unit, measure 220V has reached the binding post, after turning off the power supply, measure the resistance of the compressor winding is normal, the starting capacitor of the compressor has not been charged and discharged, obviously the circuit has been opened, after replacing the starting capacitor, troubleshooting.
What is the matter with the air conditioner outside unit not turning - the capacity of the air conditioner's power cord is insufficient.
What to do if the air conditioner does not rotate: the 220V power supply is normal before moving, and the voltage measured at the moment of compressor start is only about 150V, which is mostly due to the improper selection of the 220V power supply line, and the cross-section of the wire is fine.
What to do if the air conditioner does not rotate, the above are the main reasons and solutions for the air conditioner not turning. In fact, the air conditioner is not installed once and for all, and consumers also need to clean and maintain it regularly during the later use process; Secondly, if the air conditioner fails, we can first conduct a simple investigation to understand the cause and severity of the faulty product, and then decide whether to find someone to repair it, which may also help you reduce a lot of expenses.
The frost of the thick pipe of the outdoor unit is caused by the fact that the cold energy of the evaporator cannot be completely dissipated during the refrigeration process, and the temperature of the evaporator is too low. >>>More
1.If the installation stability of the indoor unit is not good, when the outdoor unit of the air conditioner is running, the copper pipe is connected to the indoor unit. If the indoor unit is not stable enough, it will be affected by the compressor, resulting in the resonance of the indoor unit. >>>More
Causes and maintenance methods for failure of air conditioning and refrigeration outside unit not working: >>>More
Check whether the fan starter is damaged, the possibility of the fan motor being broken is very small. If the dirty cold air of the internal evaporator cannot be dispersed or the condenser of the external unit is dirty and the heat dissipation is poor, it will cause the compressor to be protected from high temperature and stop working, then the fan motor will definitely not rotate if it is also high. Generally, in addition to the reason of the fan motor itself, such failures are caused by poor heat dissipation under normal circumstances. >>>More
There are the following reasons why the air conditioner compressor is not working: >>>More