-
At present, there seems to be no such elevator on the market, there is no need for this First of all, there is an alarm bell in the elevator and emergency lighting in the elevator in the external ** or intercom system in the case of a power outage There is no problem, there is an emergency power supply system It is directly connected with the 24-hour manned duty room, the problem is that you just press the button with the alarm bell and someone will talk to you, and now it is the state that requires that the intercom system must be intact when using the elevator Otherwise it is unqualified, If the intercom system does not work, the elevator maintenance company will be fined 2000-5000 yuan, and will be held responsible. There is also the general elevator is now covered by mobile phone signals, that is, the possibility of not covering all the blind spots is not large, the call can not be a message should be no problem, mainly if the elevator external intercom system can not be used, and the elevator is a blind spot You are set up to place the mobile phone card is useless.
-
The first floor and the second floor have not been on the point lz actually does not need any equipment Now the state has just issued a document requiring the elevator to have an emergency help system That is, the distress intercom Generally, the elevator that has just been installed is a 3-party call, that is, the machine room - car top - car - pit, if there is a trapped accident, then the duty staff may not know Now the house regulations should be the first time to notify the maintenance or duty personnel if there is a trapped person accident So there is another 5 party intercom room - car top - car - pit - duty room, If there is a trapped accident, the elevator maintenance unit does not appear in time, so that the trapped person is trapped for more than 2 hours, a fine of more than 20w will be imposed, so LZ do not worry
-
No, it's better to install a program-controlled ** in the car.
-
1. Stay calm and comfort the people who are trapped together, explaining that there will be no danger and that the elevator will not fall.
2. Use the alarm bell or walkie-talkie or mobile phone for help, if there is no alarm bell or walkie-talkie, and the mobile phone is out of order, you can knock on the door and shout, if you are afraid of hand pain, you can take off your shoes and knock on it, and ask for someone to rescue immediately.
3. If you can't find the elevator mechanic immediately, you can ask someone outside to call the firefighter. Firefighters usually twist the elevator up or down to the nearest floor and open the door.
4. If there are no trained rescuers outside, do not climb out of the elevator on your own.
5. Don't try to forcibly open the inner door of the elevator, even if it can be opened, it may not be able to reach the outer door, and it is of course not possible to open the outer door to get out safely. Grease on the exterior wall of the elevator can also cause people to slip.
6. If there is an emergency exit on the ceiling of the elevator, do not climb out. Once the exit plate is opened, the safety switch immobilizes the elevator.
7. If you are trapped in the elevator of a commercial building in the middle of the night or on weekend afternoons, it is possible that no one approaches the elevator for several hours or even days. In this case, it is best to endure hunger and thirst, listen to the movement outside, and try to get his attention if there is a pedestrian passing by.
-
Elevator failure emergency rescue operation procedures.
Maintenance personnel should rush to the scene in time after receiving the rescue notice; Determine the exact position of the car and whether the hall door and car door are closed (to prevent artificial prie open of the car door), and at the same time keep in touch with the car, and inform the driver to let him know that we are dealing with the fault and will rescue them immediately, there will be no danger, please be quiet.
Complete the following tasks according to different situations:
1. The elevator is stuck in the middle of the floor (if there is electricity):
1. The maintenance personnel go to the computer room and pull the maintenance switch to the maintenance position;
2. Press the upward button and look at the leveling sign;
3. After the elevator arrives at the nearest leveling position, open the door and let it go.
2. Roofing: 1. The maintenance personnel go to the computer room to pull the maintenance switch to the maintenance position;
2. Press the up (or down) button according to the specific situation, and look at the flat mark;
3. After the elevator reaches the leveling position, open the door and release it.
3. Squatting: 1. The maintenance personnel go to the computer room and pull the maintenance switch to the maintenance position;
2. Press the upward button and look at the leveling sign;
3. In the machine room, one person loosens the brake with a brake wrench, and the other person uses a manual turning car (handwheel special tool) to use the elevator to reach the nearest leveling area with reference to the leveling sign, and releases the brake wrench to make the brake hold tightly and the elevator stops;
4. Then go to the flat floor area and open the hall door to release the passengers;
5. Overhaul the elevator, troubleshoot and test run.
The main power supply must be cut off first before manual cranking.
-
In the event of a fire, if the passenger is in the elevator, the elevator should be stopped at the fire.
or the staircase where the fireworks did not spread, and then escape through the staircase.
The lifting speed of passenger elevators is usually about 1 meter per second, and the elevator is faster than one meter per second, and some people will feel unaccustomed to it, and people with high blood pressure and heart disease will also feel dizzy and uncomfortable. Riding an ordinary elevator can feel unaccustomed, and sugar can be put in the mouth to help correct the eardrum's ability to adapt to changes in external air pressure.
-
In the event of an emergency, passengers shall take the following distress and self-protection measures:
1) Call for help through the alarm bell, intercom system, mobile ** or prompts in the elevator car, if there are patients or other critical situations in the elevator car, the rescue personnel shall be informed.
2) Keep a certain distance from the elevator car door or the car door that has been opened, and obey the command of the management personnel.
3) Before the rescuers arrive at the scene, they shall not pry the elevator car door or climb the safety window, and shall not extend any part of the body out of the elevator car.
4) Keep calm and do knee bending movements to reduce the discomfort of the elevator emergency stop. Elevator use management unit to receive the elevator emergency handling procedures:
1) After the on-duty personnel find that the elevator under their management has an emergency or receives a signal for help, they shall immediately notify the professionals of the unit to go to the scene for processing, and at the same time notify the elevator maintenance unit.
2) The personnel on duty should use the communication intercom system configured by the elevator or other feasible methods to inform the passengers trapped in the elevator car in detail of the matters that should be paid attention to.
3) The personnel on duty shall know the location of the floor where the elevator car stops, the number of trapped people, whether there are patients or other risk factors, etc., and shall immediately report to the relevant departments and units if there is an emergency.
4) After the professionals of the elevator use management unit arrive at the scene, they can first implement the rescue procedures, and if they have difficulties in self-rescue, they should cooperate with the elevator maintenance unit to implement the rescue.
Procedures for rescuing passengers trapped in an elevator car:
1) Rescue professionals arriving at the scene should first determine the position of the elevator car before carrying out rescue.
2) When the elevator car is higher or lower than the floor more than a meter, the rescue procedure shall be implemented first, and then the rescue shall be carried out in accordance with the following procedures:
1.determine the location of the elevator car;
2.Turn off the main power supply of the elevator;
3.Use the emergency unlocking key to open the elevator hall door and car door;
4.Divert passengers from the car to prevent them from falling;
5.Re-close the elevator hall door and car door;
6.Set up signs at the entrances and exits of the elevator that prohibit the elevator.
Aftercare of the elevator use management unit:
1) If a passenger is seriously injured, an emergency report shall be made in accordance with the accident reporting procedures.
2) Learn about the accident from passengers, investigate the cause of elevator failure, and assist in relevant evidence collection.
3) If it is caused by elevator failure, the elevator maintenance unit shall be urged to inspect and repair as soon as possible.
4) Submit fault and accident report materials to relevant departments in a timely manner.
-
If the elevator is out of order, call me 110 as soon as possible, or other personnel come over for help, Li Wei he doesn't mess around, if you are inside, you can be safe and secure, rescue.
-
After arriving at the floor, the elevator door is not opened generally because the secondary door opening limit switch 2km damage caused by the door opening relay is not electrified, at this time it can be checked and determined by shorting two points, if it can open the door, it means that it is 2km damaged, so it needs to be replaced 2km on the line.
3. There is no response when you press the close button.
There is no response when pressing the door closing button, which is generally caused by poor contact and damage to the AGM contact, at this time, you can short-circuit two points for inspection and measurement, and choose to repair or replace according to the specific situation.
Is the property set to hidden?
Open a random folder and view Tools - Folder Options - View. >>>More
Hello, a normal car with a sharp handbrake cannot stop the car at all, it only reduces the speed of the car. >>>More
In order to save his son, a farmer actually lifted a light truck that pressed on his son in a hurry. After his son was saved, he tried to lift the car again, but this time he couldn't lift it anyway.