1. Before installation, the compensator should check its model, specification and pipeline configuration, and must meet the design requirements.
2. Attention should be paid to the direction of the inner sleeve to be consistent with the direction of medium flow, and the hinge rotation plane of the hinge type compensator should be consistent with the displacement rotation plane.
3. For compensators that need to be "cold tightened", the auxiliary components used for pre-deformation should be removed after the pipeline is installed.
4. It is strictly forbidden to adjust the installation deviation of the pipeline by the method of deformation of the corrugated compensator, so as not to affect the normal function of the compensator, reduce the service life and increase the load of the piping, equipment and supporting components.
5. During the installation process, welding slag is not allowed to splash on the surface of the corrugated shell, and the corrugated shell is not allowed to be damaged by other machinery.
6. After the installation of the pipe system is completed, the yellow auxiliary positioning components and fasteners used for installation and transportation on the corrugated compensator should be removed as soon as possible, and the limiting device should be adjusted to the specified position according to the design requirements, so that the pipe system has sufficient compensation capacity under environmental conditions.
7. All the movable elements of the compensator shall not be stuck by external components or limit their range of activity, and the normal operation of each movable part shall be ensured.
8. During the hydrostatic test, the sub-fixed pipe frame equipped with the end of the compensator pipeline should be strengthened so that the pipeline does not move or rotate. For the compensator and its connecting pipeline used for gas medium, it is necessary to pay attention to whether it is necessary to add a temporary bracket when filling with water. The 96 chloride ion content of the water cleaning solution in the hydrostatic test does not exceed 25ppm.
9. After the hydrostatic test, the water in the wave shell should be drained as soon as possible, and the inner surface of the wave shell should be dried quickly.
10. The insulation material in contact with the compensator bellows should not contain chlorine.
-
Here are some of the well-known brands recognized in the compensator industry that are widely recognized and have a great reputation. Although the ranking may change due to time and market conditions, the following brands are generally considered to be among the top brands in the valve industry: Water System Valves and Industrial ValvesThe following more influential first-line brands can be used as a reference, but are for reference only:
Suzhou Neway Valve, Shanghai Qizhong Valve, Shanghai Guanlong Valve, Sanhua, Su Yan, Shentong, Su Valve, Nanfang, Jiang.
First, the word Yao. The above manufacturers are only estimates and references, and the specific situation may vary or fluctuate at any time due to changes in a series of factors such as changes in the market, the size of the competition pattern, and the stability of product quality. As an indispensable key device in industrial production and civil facilities, the quality and reputation of the valve brand directly affect the satisfaction and trust of users.
These brands are known in the valve industry for their innovative technology, high-quality products and reliability. It is important to note that the market and industry are evolving rapidly, and different rankings may vary depending on time and region. For the most up-to-date ranking information, it is recommended to refer to industry reports, professional organizations or market research data for more detailed and accurate information.
-
Corrugated compensator, also commonly called expansion joint, or expansion joint, belongs to a compensation element. It is composed of the bellows (an elastic element) and the end pipe, bracket, flange, conduit and other accessories that constitute its working body, and uses the effective expansion and contraction deformation of the bellows of its working body to absorb the dimensional changes caused by thermal expansion and cold contraction of pipelines, conduits, containers, etc., or to compensate for the axial, lateral and angular displacements of pipelines, conduits, containers, etc., and can also be used for noise and vibration reduction, which is widely used in modern industry. Corrugated compensator installation and use requirements.
1. Before installation, the corrugated compensator should check its model, specification and pipeline configuration, and must meet the design requirements;
2. For the corrugated compensator with an inner sleeve, attention should be paid to making the direction of the inner sleeve consistent with the direction of medium flow, and the hinge rotation plane of the hinge corrugated compensator should be consistent with the displacement rotation plane;
3. The corrugated compensator that needs to be "cold tightened", and the auxiliary components used for pre-deformation should be removed after the pipeline is installed;
4. It is strictly forbidden to adjust the installation deviation of the pipeline by the method of deformation of the corrugated compensator, so as not to affect the normal function of the compensator, reduce the service life and increase the load of the piping, equipment and supporting components.
5. During the installation process, welding slag is not allowed to splash on the surface of the corrugated shell, and the corrugated shell is not allowed to be damaged by other machinery.
6. After the installation of the pipe system is completed, the yellow auxiliary positioning components and fasteners used for installation and transportation on the corrugated compensator should be removed as soon as possible, and the limiting device should be adjusted to the specified position according to the design requirements, so that the pipe system has sufficient compensation capacity under environmental conditions.
7. All the movable elements of the compensator shall not be stuck by external components or limit their range of activity, and the normal operation of each movable part shall be ensured.
8. During the hydrostatic test, the sub-fixed pipe frame equipped with the end of the compensator pipeline should be reinforced, so that the pipeline does not move or rotate, and whether it is necessary to add a temporary bracket when filling the compensator and its connecting pipeline for the gas medium, and the 96 chloride ion content of the water cleaning solution for the hydrostatic test does not exceed 25ppm;
9. After the hydrostatic test, the water in the wave shell should be drained as soon as possible, and the inner surface of the wave shell should be dried quickly.
10. The insulation material in contact with the compensator bellows should not contain chlorine.
-
1. Before the installation of the bellows compensator, check whether its model, specification and pipeline configuration meet the design requirements.
2. For the compensator with an inner sleeve, the direction of the inner sleeve should be consistent with the flow direction of the medium, and the hinge rotation plane of the hinge compensator should be consistent with the displacement rotation plane.
3. For the compensator that needs to be "cold tightened", the auxiliary parts used for pre-deformation shall not be removed before the pipeline is installed.
4. It is strictly forbidden to adjust the installation tolerance of the pipeline by the method of corrugated compensator deformation, so as not to affect the normal function of the compensator, reduce the service life of the pipeline system, equipment and supporting components, and increase the load.
5. During the installation process, the welding slag is not allowed to splash on the surface of the wave shell, and the wave shell is not allowed to have other mechanical damage.
6. After the installation is completed, the yellow auxiliary positioning elements and fasteners used for installation and transportation on the corrugated compensator should be removed as soon as possible, and the limiting device should be adjusted to the specified position according to the design requirements, so that the pipeline system has sufficient compensation capacity under environmental conditions.
7. All the moving parts of the compensator are not blocked or restricted by the external parts, and the normal operation of the moving parts is guaranteed.
-
First, when the limb seepage corrugated compensator is used in the pipeline, more attention must be paid to assembly and maintenance, in order to ensure normal operation, the joint must not leak, and the condensation tank must not be less water, and it is necessary to maintain and add water appropriately. Originally, it was other self-powered corrugated compensators, and it was necessary to pay attention to maintenance and daily maintenance in order to be filial.
2. The closed characteristics of the corrugated compensator refer to the level of each sealing part to prevent the leakage of substances, which is also a technical performance index. There are three closed parts: the contact between the compensator and the two protrusions of the high-pressure gate valve; where the filler is mated to the pipe and pneumatic quick coupling; The junction with the screw cap.
-
Corrugated compensator in the assembly process, because the installation and use is unreasonable, or when the bearing force is too high, will be stretched and distorted effect, when the internal stress caused by tension or distortion out of the compressive strength of the reinforcement mesh sleeve, the plastic mesh bag of the trinity welding position or the plastic mesh bag of other positions will be torn off, so that the outer drum is damaged, resulting in the leakage of the difficult substance, so the design scheme and model selection should be specified, and the installation is appropriate and accurate.
During the installation of the corrugated bridge compensator, the weld shall not splash on the surface of the corrugated shell, and the corrugated shell shall not be damaged by other mechanical equipment. After the installation of the pipeline is completed, the prefabricated components and standard components should be dismantled as soon as possible as an aid in installation and transportation, and the positioning equipment should be transferred to the required part in accordance with the design regulations, so that the pipeline has sufficient compensation capacity in the natural environment. Because it is more used in the management system of heating and heating pipes, its heat resistance is its physical function, and sometimes the temperature will be high, so the high temperature resistance of the raw materials used in the production and manufacture of it can be regulated, and even sometimes it is necessary to take some thermal insulation and heat removal methods to improve.
The corrugated compensator has enough winding conveying pipelines to avoid vibration of residential pipelines, and is suitable for steam, liquefied gas, gas, fuel oil, **, chemicals, etc. The basic increase in the amount of welding current to improve the flowability is not large, and it will also lead to fusion overtemperature, expand the thermal crack, volatilize the deoxidizer in it, and cause pores. After the tailored welding, the surface layer should be inspected, and the pressure compressive strength test and tightness test should be carried out according to the working pressure required by the engineering drawings, and there was no leakage and the design regulations were complied with.
Corrugated compensator.
-
Compensator installation precautions and installation methods:
1. The compensator is a special pipeline component, the installation is complex and the requirements are strict, and it is necessary to calculate the thrust of the pipeline and the force of the injection fixed support, so it cannot be installed without authorization, otherwise it will cause an accident. Therefore, the installation must be carried out with the detailed configuration of the pipeline construction drawings and pipe supports provided by the professional design department, and refer to the requirements of the compensator installation instructions.
2. The pipeline for installing the compensator must be properly guided and fixed in order to make the compensator play a role, so the setting of the guide and fixed bracket must be carried out in strict accordance with the relevant technical data of the design department.
3. The bellows used in the compensator is formed with thin-walled stainless steel plate, so it is necessary to pay attention not to damage the bellows due to knocking, scratching, arc striking, welding spatter and other reasons during transportation, hoisting and welding.
4. Before installation, the bellows and foreign bodies in the pipeline should be removed to ensure the normal movement of the bellows.
5. The compensator with flow direction requirements should be installed according to the requirements of the medium flow direction arrow.
6. In order to make the bellows in good working condition, the deformation of the compensator, including axial, transverse, torsion, etc., can not be used to correct the installation error of the pipe system position during installation.
7. Before the operation of the system, the small tie rod is generally not recommended to be removed, but after the suppression is completed, the inner nut is loosened according to the compensation amount.
8. When purchasing, do not only rely on the model or code, but provide data to the manufacturer, and design and produce by the manufacturer to ensure the service life or quality.
One. Compensator Specifications:
The main products of Baishun brand bellows compensator are axial, transverse, angular and hot air pipelines and special four categories of corrugated compensators. It can manufacture all kinds of compensators with working pressure, temperature range -200-1300 and nominal diameter DN32-8000mm, and can develop other types and uses of corrugated compensators and non-metallic compensators for customers according to the working environment, conditions and fatigue failure times. >>>More
Compensator. Installation precautions and installation methods: >>>More
The effective area is one of the basic performance parameters of the bellows, which characterizes the ability of the bellows to convert pressure into concentrated force, and the effective area is an important parameter when using the bellows to turn pressure into concentrated force output. >>>More
No, the directly buried corrugated compensator is mainly suitable for axial compensation, and at the same time has super bending resistance, so the impact of pipeline sinking is not considered. Directly buried corrugated compensator shell and guide sleeve to achieve free telescopic compensation other performance is the same as ordinary corrugated compensator. The axial internal pressure corrugated compensator consists of a bellows and two end pipes, the end pipes are either directly welded with the pipe, or welded with the flange and then connected with the pipe flange. >>>More
Scope of application of bellows:
Fluids: natural gas, artificial gas, petroleum liquefied gas, air mixture, biogas, etc. >>>More