What does it mean for the screen of the Woxi wall hung boiler to display E6

Updated on number 2024-05-12
9 answers
  1. Anonymous users2024-02-10

    This indicates that the wall-hung boiler is currently in failure. The number 6 indicates a corresponding failure mode. Because the fault number of each wall-hung boiler brand is different, it is better to directly consult the after-sales consultation of Woxi brand wall-hung boiler.

  2. Anonymous users2024-02-09

    This is the wind pressure switch fault according to the following method to troubleshoot, cause analysis:

    1. The pressure transfer pipe is loose or plugged in the wrong position, or the connection with the low pressure port is not tight, there is leakage, the negative pressure is reduced, and the wind pressure switch cannot be closed.

    2. The smoke pipe is blocked, the pipe is too long, the bend angle is too much, the external wind pressure is too large, etc., the exhaust is not smooth and the negative pressure is reduced, and the negative pressure switch cannot be closed.

    3. The terminal of the micro switch is oxidized and rusted or the spring is weak and fails. Causing poor contact or non-action.

    4. The assembly of the wind pressure switch is damaged, such as the aging of the diaphragm and the increase of perforated spring force.

  3. Anonymous users2024-02-08

    Protection against dry boiling caused by overheating of the effluent temperature. When the hot water temperature exceeds 75, the <> thermostat will automatically break the circuit and display E6; Clause.

    2. When the dry burning protection wire on the heat exchanger is fused or damaged, the water heater will also display E6**; Clause.

    3. When some components of the computer version are damaged, e6 will be displayed; Clause.

    Fourth, the relay in the alarm of Vantage water heater.

  4. Anonymous users2024-02-07

    What does it mean that the natural gas wall-hung boiler shows 10? Different brands of gas wall-hung boilers have different failures. To know what the gas wall-hung boiler shows 10 means, we must first know the brand and model of the wall-hung boiler.

    If it is a British Woxi wall-hung boiler, the fault ** is displayed as: E10, indicating that the boiler is short of water.

  5. Anonymous users2024-02-06

    The Haydn wall-hung boiler shows that the E6 is a smoke exhaust or wind pressure failure, and you can contact the official after-sales personnel for maintenance.

    The wall-hung boiler shows E6: The wall-hung grate smoke exhaust system is blocked or the wind pressure signal is faulty.

    Solution: Close the wall-hung boiler, check whether the smoke exhaust pipe of the boot sock is blocked, if there is a blockage, it needs to be cleared, and it can be re-run, if it still cannot be started or the fault occurs many times, you need to contact the technician.

  6. Anonymous users2024-02-05

    The failure of wall-hung boiler E6 refers to the failure of smoke exhaust, which means that the wall-hung boiler cannot normally eliminate the exhaust gas generated by the combustion of the wall-hung boiler, resulting in the error of the wall-hung boiler.

    The cause: clogged smoke pipes.

    Solution: If there is a foreign object inside the smoke pipe that is blocked, as long as the blockage is cleaned up, the dirt attached to the inner wall of the smoke pipe can be restored.

  7. Anonymous users2024-02-04

    The master tells you that the induction cooker shows what is going on with the E6, and you can understand it in seconds after reading it.

  8. Anonymous users2024-02-03

    Summary. The wall-hung boiler shows E6 because of the smoke exhaust fault, which actually means that the wall-hung boiler cannot normally eliminate the exhaust gas generated by the combustion of the wall-hung boiler, resulting in the error of the wall-hung boiler.

    The wall-hung boiler shows E6 because of the smoke exhaust fault, which actually means that the wall-hung boiler cannot normally eliminate the exhaust gas generated by the combustion of the wall-hung boiler, resulting in the error of the wall-hung boiler.

    The solutions are: 1. The smoke pipe blocks the eggplant base plug. If there is a foreign object inside the smoke pipe that is blocked, it can be restored by cleaning up the blockage and removing the dirt on the inner wall of the smoke pipe with a smile.

    2. The wind pressure switch is faulty. The wind pressure switch is a safety device for Zheng Sellan, its function is to check whether the flue is unobstructed, if it is open, it will stop working, if it fails, regardless of whether the distribution is unblocked, it will stop working, it will be called false and there will be smoke exhaust error, at this time the wind pressure switch needs to be replaced.

    3. Fan failure. The fan is responsible for transporting the burning oxygen and exhaust gas to the wall-mounted potato early age furnace, if it fails, there will be an error, and the fan can be replaced to open the number.

    4. The connection of the fan or switch falls off. The connection of the fan or the air pressure switch will fall off the smoke pipe failure, as long as the line that falls off is welded, for the user who does not fail, do not easily try to weld, it is best to ask the personnel of the dry search industry to repair the file.

  9. Anonymous users2024-02-02

    Summary. Insufficient pressure fault:

    Fault phenomenon: The pump does not run, the controller alarms, and the fault displayed on the display screen is insufficient pressure.

    Cause of failure: a) The pipeline is short of water, and the pressure gauge shows that the water pressure of the pipeline is insufficient.

    b) Failure of the pressure switch.

    c) There is a large amount of air in the duct system. Workaround:

    a) Replenishment of water for lack of water in pipelines; If the pipeline leaks, find a way to plug the leak.

    What to do if the wall-hung boiler shows e6.

    Your question has been received sensitively, typing takes a little time, please wait a while, please don't end the consultation, you can also provide more effective information, so that I can better answer for you!

    The wall-hung boiler shows E6

    Kiss wait !! Here for you to enquire!

    Here for you to inquire !!

    Fault phenomenon: The pump does not run, the controller alarms, and the display screen shows the difficulty of the trouble** for insufficient pressure. Cause of failure:

    a) There is a shortage of water in the pipeline, and the pressure gauge shows that the water pressure in the pipeline is insufficient. b) Failure of the pressure switch. c) There is a large amount of air in the duct system.

    Solutions and brief letters: a) water supply for pipeline shortage; If the pipeline leaks, find a way to plug the leak.

Related questions
3 answers2024-05-12

What brand of wall-hung boiler is good, the top ten brands of wall-hung boiler ranking recommend the top ten brands One of the top ten brands of wall-hung boiler: Beretta wall-hung boiler Beretta wall-hung boiler is a brand of Italian Riello Co., Ltd., founded in 1973. It is one of the largest heating equipment manufacturers in Italy and a major supplier in the field of mining in China. >>>More

10 answers2024-05-12

1. Power selection: The selection of wall-hung boiler should be based on many factors such as the area where your house is located (different climatic conditions in different regions), location, house area, enclosure structure (villas, bungalows, energy-saving buildings, old buildings, etc.), floor height, floor, unit, heating terminal heat dissipation type (floor heating, radiator, fan coil unit is the most common) and many other factors. >>>More

14 answers2024-05-12

Advantages of wall-hung boiler heating.

1.The advantage of Anerrui wall-hung boiler heating is that it is energy-saving and environmentally friendly, because it does not waste a lot of heat on the pipeline like central heating. Comparatively speaking, wall-hung boiler heating improves heating efficiency. >>>More

12 answers2024-05-12

1.The difference between condensing wall-hung boiler and ordinary wall-hung boiler - comparison of energy saving: >>>More

8 answers2024-05-12

1. Connect the power supply to the wall-hung boiler.

2. Turn on the wall-hung boiler, some wall-hung boilers will have a switch. >>>More