What if the power goes out if the gas switch to the gas stove is made with a solenoid valve?

Updated on home 2024-05-19
17 answers
  1. Anonymous users2024-02-11

    Find a battery that matches the voltage of the solenoid valve, connect it and you can use it: Sunset - Assistant Level 2 5-9 15:42 Generally in the case of normal power loss, it is a closed valve state. Make a small DC drive. or bypass hand valves.

    Author:zgz1979 - Tong Sheng Level 1 5-9 15:47Go to the restaurant downstairs to eat!

    Author:stonetimes - Xiucai Level 2 5-9 16:42 It's OK to connect a DC battery, and the voltage should be sufficient.

    Author:zdwzf - probationary period level 5-9 18:46 If you add a bypass valve, it is just right, you think, when working automatically, open the bypass valve a little bit, about 15% of the flow rate you want, if the master Fu picks up the pot, the main solenoid valve is closed, it is completely dependent on the bypass pipe to vent a little gas, to achieve the purpose of small fire you want.

    If you put the pot down, at this time the main solenoid valve is opened, and the gas passes through completely, reaching the high fire you want. If there is a power outage, don't be afraid, you can do it manually, and the bypass valve will be completely opened, and it will be a fire, just use it as if it was not changed to automatic.

    Author: Engineer Li Wei - Assistant Level 2 5-9 21:13 The general solenoid reversing valve has a test button, press it and you can use it all the time.

    By:TGR1234567890 - Trial period Level 1 5-9 21:15 With normally open solenoid valve, dude, are you making energy savers?

    If so, let's have a good chat. My one: heguangw - probationary period level 1 5-11 17:41

  2. Anonymous users2024-02-10

    Find a battery that matches the voltage of the solenoid valve, connect it and you can use it

  3. Anonymous users2024-02-09

    It's OK to connect a DC battery, and the voltage should be sufficient.

  4. Anonymous users2024-02-08

    The general solenoid reversing valve has a test button, press it and you can use it all the time.

  5. Anonymous users2024-02-07

    Generally, it is in the closed valve state under normal power loss. Make a small DC drive. or bypass hand valves.

  6. Anonymous users2024-02-06

    Go to the restaurant downstairs for dinner!

  7. Anonymous users2024-02-05

    The solenoid valve of the gas stove is an important part of the gas stove, which is used to control the ** and close of the gas stove and ensure the safe use of the gas stove. However, sometimes, the solenoid valve is not closed, resulting in gas leakage and bringing potential safety hazards to users. The reasons why the solenoid valve of the gas stove does not close are as follows:

    1.The solenoid valve itself is faulty.

    The solenoid valve of the gas stove is a device that combines mechanical and electrical, which is prone to problems in long-term use. For example, the accumulation of scale, aging and damage of components, poor contact, etc., can lead to the failure of the solenoid valve, which can lose control and cannot be closed.

    2.The gas stove igniter is damaged.

    The gas stove spot clearing firearm is one of the key components to start the gas stove. If the igniter is damaged or in poor contact, it will result in unsuccessful ignition of the gas stove and the gas will be sprayed all the time. In this case, the solenoid valve remains open and cannot be closed.

    3.Leaking air in the pipes.

    If there is a leak in the gas stove, the gas in the pipe will continue to leak outward, causing the solenoid valve of the gas stove to lose control. When the solenoid valve of the gas stove cannot be closed, any ignition operation has the potential to cause a large fire and bring immeasurable harm to the home.

    4.The micro switch is faulty.

    The micro switch of the gas stove is mainly used to detect the status of the gas stove, such as whether there is a pot at the bottom of the pot, overtime protection, etc. If these micro switches are damaged or the contact chain is not properly connected, the gas hob solenoid valve will not get the correct signal and thus will not close properly.

    In conclusion, there are many reasons why the solenoid valve of a gas stove does not close. When using the gas stove normally, it is important to pay attention to regularly inspect and maintain the gas stove to maintain the normal working condition of all parts of it, especially the solenoid valve part, to ensure that the solenoid valve can be opened and closed normally, which is not only convenient and fast when using, but also can ensure the safety of users.

  8. Anonymous users2024-02-04

    Hello, I am happy to serve you and give you the following answers: the closing time of the solenoid valve of the socks is generally seconds, but sometimes there will be a delay in the celebration of the hall, which is due to the lack of magnetic grip strength of the magnet inside the solenoid valve or the magnetic attenuation of the magnet magnetic force of the solenoid valve. Workaround:

    1.Check whether the magnet magnetic force inside the solenoid valve is sufficient, if it is insufficient, you can replace the solenoid valve with a new one; 2.Check whether the magnet magnetic force of the solenoid valve is attenuated, if it is attenuated, you can replace the solenoid valve with a new one; 3.

    Check whether the wiring of the solenoid valve is correct, if not, you can rewire it; 4.Check whether the power supply voltage of the solenoid valve is normal, if not, you can replace it with a new power supply voltage. Personal Experience:

    When using the solenoid valve, you should pay attention to check whether the magnet magnetic force of the solenoid valve is sufficient, check whether the magnetic force of the solenoid valve is attenuated, check whether the wiring of the solenoid valve is correct, and check whether the power supply voltage of the solenoid valve is normal to ensure the normal use of the solenoid valve.

  9. Anonymous users2024-02-03

    Hello, I am glad to serve you and give you the following answers: the closing time of the solenoid valve of the gas stove is generally 1-2 seconds. If the solenoid valve is closed for too long, it may be due to a problem with the solenoid valve itself or due to a low supply voltage.

    Workaround:1Check if there is a problem with the solenoid valve itself, and if there is a problem, you can replace it with a new solenoid valve.

    2.Check whether the power supply voltage is normal, if the voltage is too low, you can replace it with a new power supply voltage. 3.

    Install the Mamzen solenoid valve on a stable bracket to prevent the solenoid valve from malfunctioning due to vibration. Personal Experience:1

    When installing and maintaining the solenoid valve, it is necessary to pay attention to the stable installation to prevent the solenoid valve from losing its cavity. 2.Check the power supply voltage regularly to ensure that the power supply voltage is normal.

    3.Inspect the solenoid valve regularly to ensure that the solenoid valve is working properly.

  10. Anonymous users2024-02-02

    Hello, it is a pleasure to serve you and give you the following answers: The closing time of the solenoid valve mainly depends on the type and structure of the solenoid valve, generally between seconds and seconds. There are several reasons why something can go wrong:

    1. Structural reasons of the solenoid valve: due to the unreasonable structural design of the solenoid valve, the closing time is too long, which has adverse effects. Second, the power supply reason:

    Due to the unstable supply voltage, the operation of the solenoid valve is delayed, and the closing time is extended. 3. Wiring reason: due to the improper wiring of the solenoid valve, the closing time of the solenoid valve is prolonged.

    Solution: 1. Check whether the solenoid valve structure is reasonably designed and readjust the closing time; 2. Check whether the power supply voltage is stable, if not, measures should be taken to adjust it; 3. Check whether the wiring of the solenoid valve is correct, if not, it should be rewired. Tips:

    When installing the solenoid valve, attention should be paid to checking whether the structure is designed and reasonable, whether the power supply voltage is stable and whether the wiring is correct, and the thick acres of branches to avoid the above problems.

  11. Anonymous users2024-02-01

    The solenoid valve of most cookers in China does not need batteries, and its suction is "powered" by thermocouples, so the ignition is not affected by the lack of power. When vibrating, the closing spring "overcomes" the electromagnetic force with the help of an external force, thus cutting off the gas path and causing the flame to be extinguished.

    At present, there are two main types of flame-out protection technologies used in domestic stoves, one is the thermoelectric flame-out protection device, and the other is the ion flame-out protection device. The former only uses one battery, which is mostly used in ordinary stoves, and the battery only starts to ignite, so it will take a long time; When ignition, the thimble designed at the bottom of the knob will push open the closing spring and open the air path, and when the flame is stable, the thermoelectric potential of the thermocouple just overcomes the elastic force of the closing spring and maintains the engagement of the solenoid valve; However, the disadvantage is that the thermocouple is easy to age, resulting in the phenomenon of the stove letting go (when ignition) and turning off the fire. (The problem encountered by the landlord is caused by the failure to remove the sealing ring during maintenance) The latter generally uses two batteries, mostly used for infrared cookers (a small number of ordinary cookers are also used), the battery not only starts the ignition, but also undertakes the whole process of the solenoid valve, so the time will be shorter; When ignition, the pulser should release an electric spark, the solenoid valve should use an instantaneous high current to push open the closing spring and open the gas path, after the flame is stable, the solenoid valve should overcome the elastic force of the closing spring and keep the suction, and the pulser should detect the existence of the flame, so it will continue to consume electricity; However, thermocouple technology is relatively mature, and there are few "halfway couple" failures.

    The cooker is vibrated and conducted to the closing spring, and the reaction force of the spring will increase, but the solenoid valve keeps the magnetic force of the coil relatively constant, and the balance of elastic force and magnetic force is broken, and the elastic force will push the sealing ring to move, close the gas path, and cause the "accidental" extinguishing of the flame.

    Despite the obvious defects of thermoelectric technology, China's stove industry tends to be conservative and dependent on inertia, coupled with the silence of users, the characteristics of the industry have continued.

  12. Anonymous users2024-01-31

    Because the solenoid valve is usually closed, its opening is opened when the knob is pressed, and the open state is maintained by the microcurrent provided by the thermocouple, and the thermocouple is maintained by the flame, and the three form a self-locking. There is no flame, the valve solenoid valve is reset and closed under the action of the spring, which plays the role of flame-out protection. The cause of automatic flameout may be the occasional fouling of the thermoelectric.

    It is impossible for the circuit to be unplugged. When looking for someone to repair the stove, pay attention to the solenoid valve (remove the rubber valve plate), which is the most dangerous.

  13. Anonymous users2024-01-30

    You can find a repair company to show you! 010-87939593 This is very good! After the repair, it can be guaranteed for three months.

  14. Anonymous users2024-01-29

    Hello, dear. The reason why the gas solenoid valve does not work 1, the automatic flameout function of the gas stove solenoid valve fails, and the wiring gasket in the valve body cannot be energized, resulting in the solenoid valve of the gas stove not working. Solution:

    Ask a professional maintenance personnel to repair or replace a new valve body. Friends with strong hands-on ability can update a valve body by themselves. After replacing the solenoid valve, you can use thick soapy water to check whether there is air leakage.

    2. The battery pack is not strong enough, which will lead to insufficient ignition of the pulse. The magnetic poles will not be sucked, and the gas will not be able to enter. Solution:

    Replace with a new battery pack. 3. Galvanic peroxidation or feedback cable virtual connection. Solution:

    In the former, the thermocouple is replaced; The latter, once again edit the electric ascension mountain resistant cable. The infrared stove uses the ion flameout guarantee, which will not occur, and when changing the stove, you can consider changing the infrared noisy spring stove. 4. The solenoid valve cannot work, perhaps it is blocked by foreign objects.

    Solution: There is a foreign body blockage, resulting in no work. As long as you dredge it with a thin wire, you can rule out the abnormality.

  15. Anonymous users2024-01-28

    01 Poor circuit contactIf the gas stove is used for a long time, it is easy to have poor contact, resulting in failure to ignite or automatic flameout. In this regard, we can check whether the positive and negative poles of the battery box are rusty, and whether the wiring is not in good contact. If there is, remove the rust and connect the lines accurately.

    02Check whether the battery is electric, and the gas stove battery is dead, which is the direct cause of the flameout. In this case, we need to check if there is gas on the gas stove. Yes, at all.

    then determine whether it is a problem with the battery; If the battery is out of charge, replace it with a new one. 03 Pipeline blockageIn general, the gas stove pipeline is blocked, which will also cause the gas stove to fail to ignite or automatically turn off. For this, we need to check the outlet valve.

    Normally, you can smell the gas Nakai, but the gas stove does not catch fire, it is likely that the gas is clogged. At this time, we only need to dredge it in time to use it normally. 04 Overvoltage ProtectionNow, in order to ensure safety, many gas stove products have added overvoltage protection function.

    When this kind of gas stove is used, once it exceeds the standard pressure, it will not be started again, and it will naturally not ignite. For this, we only need to replace a pressure reducing valve. 05 When the position of the ignition needle deviates from the gas stove hole, there are certain requirements for the distance between the ignition needle and the fire cover.

    If the distance deviates too much, the gas stove will not catch fire.

  16. Anonymous users2024-01-27

    Cause Solution:

    1. If the solenoid valve itself is poor or damaged and cannot be sucked, replace the new solenoid valve with a new one according to the original model to ensure that it can be sucked and closed normally.

    2. If the driving voltage of the solenoid valve is not supplied normally due to the failure of the pulse ignition assembly, the pulse igniter of the same model can be replaced.

    3. The micro switch is damaged, resulting in the pulse igniter not working and no voltage supply to the solenoid valve, the micro motion is damaged, and it is replaced directly, and the spring under the knob between the injections should not be lost when replacing.

    4. The battery is insufficient to push the solenoid valve to work, and the battery is insufficient to replace the new battery with sufficient power.

    Precautions: The gas stove is not ignited or delayed ignition is one of the reasons why it is easy to cause ignition, so when it is found that the gas stove is not ignited or delayed ignition, it must be timely asked to ask professional repair personnel to carry out professional repairs to ensure safe use and avoid accidents such as fire and **.

  17. Anonymous users2024-01-26

    The same question, 1, first open the stove, then open the gas can be used normally, 2, first open the gas, then open the stove, the solenoid valve can not be sucked in, can not be used normally, (solution: first turn off the gas, and then use a screwdriver to disassemble the hose between the gas and the stove, put the gas inside, and then install it, repeat 1).

    Summary: It may be that the air pressure causes the solenoid valve to fail to engage, no solution, and headache.

Related questions
7 answers2024-05-19

Not good. Top 10 brands of cooktops.

1 Vantage (China Famous Trademark, China Famous Brand, Top 10 Cooker Brands, Leading Brand, Zhongshan) 2 Siemens (Top 10 Cooker Brands, World Brand, China Headquarters Beijing) 3 Fotile. China Famous Brand, China Famous Trademark, Top 10 Brands of Cooker, Ningbo) 4 Boss (China Famous Brand, Top 10 Brands of Cooker, Famous Brand, Yuhang, Zhejiang. >>>More

4 answers2024-05-19

Common sense of gas stove purchase, safety and environmental protection are the selection criteria. >>>More

11 answers2024-05-19

The gas solenoid valve is a safety emergency shut-off device for gas pipelines. It can be connected with the gas leakage alarm system or connected with the fire protection and other intelligent alarm control terminal modules, etc., to realize on-site or remote automatic manual emergency shut-off of gas source to ensure gas safety. In the event of a harmful strong vibration, the valve closes automatically. >>>More

7 answers2024-05-19

The battery is good, the ignition success rate is high, and the ignition is fast. And the battery is discharged and ignited first, and when the gas is discharged, the gas will catch fire as soon as it arrives. >>>More

9 answers2024-05-19

Q: Find the classification of gas stoves.

Answer: There are several classifications of household gas stoves: >>>More