The ignition signal of the wall hung boiler is not on

Updated on home 2024-05-20
8 answers
  1. Anonymous users2024-02-11

    There are many reasons why a wall-hung boiler cannot catch fire.

    The first reason why it can't catch fire may be that the gas valve of the wall-hung boiler is not opened. Then the gas can't pass through the pipes, so it won't be able to hit.

    Another reason is that there is a problem with the pipes of the wall-hung boiler. Causing a blockage to occur inside.

    The water pressure of the wall-hung boiler is too high or too low, which will also cause the wall-hung boiler to fail.

    For details, please call us or make an appointment for maintenance.

  2. Anonymous users2024-02-10

    The common reasons for failure of the wall-hung boiler to fail to ignite are as follows:

    1. The gas pressure is abnormal.

    The gas pressure is too low to ensure normal combustion; If the gas valve is closed, it will not work, and none of these conditions will be able to ignite.

    2. The wind pressure switch is faulty.

    The air pressure switch controls the air entering the gas chamber and detects whether the exhaust gas is discharged.

    3. The water pressure is abnormal.

    The working range of the heating water pressure is that if the pressure is too small, it will not be started, and if the pressure is too high, the pressure will be automatically relieved.

    4. The ignition plate ignition needle and detection needle are damaged.

    The ignition needle is responsible for igniting the gas in the burner, and the detection needle is responsible for detecting the combustion state. If these 2 parts fail, ignition cannot be made.

    5. Gas proportional valve failure.

    The gas proportional valve is a key component to control the mixing ratio of gas and air and adjust the amount of combustion power.

  3. Anonymous users2024-02-09

    Hello, I'm glad to answer your smile The first reason: the tap water pressure is too low, this is due to the inside of the wall-hung boiler it has a setting switch to detect the water flow, when the water flow is lower than a certain value is it will start, the wall-hung boiler will stop working at this time, that is, the wall-hung boiler is not burning, if the tap water pressure is too low to cause the wall-hung boiler not to burn, only need to install a booster pump to ensure that the tap water pressure is normal, and then the wall-hung boiler will operate normally. The second reason:

    If the natural gas pressure of the natural gas wall-hung boiler is insufficient, it will cause the wall-hung boiler to go out, which is caused by insufficient gas, this problem needs to detect whether the gas pipeline is blocked, or contact the natural gas company directly, they will detect and repair, so that the natural gas is sufficient. The third reason: the flue of the wall-hung boiler is blocked; Each wall-hung banquet stove has a flue and a smoke pipe, which not only exhausts the smoke but also provides air intake, and if the flue is blocked and the oxygen is insufficient, it will automatically turn off the flame.

    Therefore, we have to clean the smoke pipe of the wall-hung furnace regularly. The fourth reason: the internal temperature sensor of the wall-hung boiler is faulty, if the sensor is faulty and the temperature of each position cannot be detected, then the wall-hung boiler will play a role in self-protection and close the wall-hung boiler.

  4. Anonymous users2024-02-08

    Dear, hello, I'm glad to answer for you: everything is normal in the wall-hung boiler is not igniting A: dear, 1

    If the gas valve is not opened, the gas cannot circulate in the pipeline, and the gas can not catch fire, so the gas valve can be opened. 2.There is a problem with the pipeline of the wall-hung boiler, the inside has been blocked, and the gas cannot circulate in the pipeline, so that the wall-hung boiler does not ignite, if the pipeline is broken and cannot be repaired, then replace the new pipeline, if the internal fault of the wall-hung boiler, then it can be repaired.

    1. The water pressure is too low or the filter screen is blocked If the water pressure of the wall-hung boiler is very low, or the filter screen at the water inlet of the wall-hung boiler is blocked, then it will cause the wall-hung boiler to not ignite. 2. Failure of ignition electrode and flame induction electrode (1) The ignition electrode and flame induction electrode of the wall-hung boiler are also due to the failure of the ignition electrode and flame induction electrode of the wall-hung boiler, and 3. The gas pipeline system is blocked.

  5. Anonymous users2024-02-07

    Summary. Kiss <>

    Hello, I have given you the answer here for your reference <>

    Kiss <>

    If the water pressure of the wall-hung boiler is very low, or the filter screen at the water inlet of the wall-hung boiler is blocked, then it will cause the wall-hung boiler to not ignite, the ignition electrode and the flame induction electrode to fail, and the wall-hung boiler does not ignite, it may also be because the ignition electrode and flame induction electrode of the wall-hung boiler are faulty, or because a lot of dust has accumulated on the electrode, and the ignition of the wall-hung boiler is not what is going on.

    Kiss <>

    Hello, I have given you the answer here for your reference <>

    Kiss <>

    If the water pressure of the wall-hung boiler is very low, or the filter screen at the water inlet of the wall-hung boiler is blocked, then it will cause the wall-hung boiler to not ignite, and the ignition electrode and flame induction electrode will fail, and the ignition electrode and flame induction electrode will fail, and the wall-hung boiler will not ignite It may also be because the ignition electrode and flame induction electrode of the wall-hung boiler are faulty, or because a lot of dust has accumulated on the electrode of the Zen stove, kiss <>

    As a result, carbon deposition occurs in the ignition electrode and flame induction electrode, which causes the wall-hung boiler to not ignite. At this time, as long as the ignition electrode and flame induction electrode of the wall-hung furnace are cleaned, the problem of Dousun not igniting can be solved. If the owner does not know how to clean it up, you can ask a professional maintenance person to come to help clean it up, or contact the after-sales department of the spare chain wall-hung boiler manufacturer to help repair the repair.

  6. Anonymous users2024-02-06

    Summary. Dear, <>

    Hello, glad to answer for you. The reasons why the wall-hung boiler cannot catch fire are as follows:1

    The water pressure of the wall-hung boiler is too low, and the filter screen with too much water inlet will cause the wall-hung boiler to go out, in this case, you must first check the water pressure, adjust the water pressure, and then clean the filter screen, and then open the wall-hung boiler, if it still cannot be extinguished, it means that there are other reasons, and you need to check again. 2.The burner and induction electrodes generate a large amount of carbon deposits, which prevents the wall-hung furnace from ignition.

    At this time, the customer needs to contact the manufacturer's repair center to professionally clean and maintain it, and carry out regular maintenance in the later stage. 3.The fire-hung boiler cannot be ignited, which may be due to a problem with the gas pipeline of the wall-hung boiler, such as insufficient gas meter gas volume, gas valve cannot be opened, etc.

    You can turn on the gas stove at home and try to light it, if it can't be ignited, there is a problem with the pipes. The aging of the solenoid valve will also cause it to fail to ignite.

    The ignition of the wall-hung boiler does not matter.

    Dear, <>

    Hello, it's a pleasure to answer for you. The reasons why the wall-hung boiler cannot catch fire are as follows:1

    The water pressure of the wall-hung boiler is too low, and the filter screen with too much water inlet will cause the wall-hung boiler to go out, in this case, you must first check the water pressure, adjust the water pressure, and then clean the filter screen, and then open the wall-hung boiler, if it still cannot be extinguished, it means that there are other reasons, and you need to check again. 2.The burner and induction electrodes generate a large amount of carbon deposits, which prevents the wall-hung furnace from ignition.

    At this time, it is necessary for the customer to contact the manufacturer's maintenance center for professional cleaning and maintenance, and to carry out regular maintenance in the later stage. 3.The fire-hung boiler cannot be ignited, which may be due to a problem with the gas pipeline of the wall-hung boiler, such as insufficient gas meter gas volume, gas valve cannot be opened, etc.

    You can turn on the gas stove at home and try to light it, if you can't light it, it's a problem with the pipe. The aging of the solenoid valve will also cause it to fail to ignite.

    1.The water pressure of the wall-hung boiler is too low, and the filter screen of the water inlet is too much will cause the wall-hung boiler to go out, in this case, the water pressure should be checked first, the water pressure of the hall crack should be adjusted, and then the filter screen should be cleaned up, and then the wall-hung boiler should be opened. 2.

    The burner and induction electrodes generate a large amount of carbon deposits, which prevents the wall-hung furnace from ignition. At this time, the customer needs to contact the manufacturer's repair center to professionally clean and maintain it, and carry out regular maintenance in the later stage. 3.

    The fire-hung boiler cannot be ignited, which may be due to a problem with the gas pipeline of the wall-hung boiler, such as insufficient gas meter gas volume, gas valve cannot be opened, etc. Ridiculous Shan turned on the gas stove at home and tried to light it, if it couldn't be lit, there was a problem with the pipe. The aging of the solenoid valve will also cause it to be unable to catch fire and rise and close.

    Is it windy or windy?

    Water pressure, air pressure stabilization, burner, element aging, etc. are all possible.

  7. Anonymous users2024-02-05

    1. If the pressure is too low in summer, it will cause the situation that it cannot be ignited, and in winter, don't let the system pressure be too low, which will not work normally. 2. If the main board or the point train has been damaged, it will not be able to light normally, which is inevitable. 3. The fan and air pressure switch are important parts of the exhaust, if they damage the ventilation duct, it will be abnormal.

    4. Forgot to open the gas valve. Suggested treatment: If the water pressure is too low, you must keep the blood pressure within a reasonable range, generally speaking, when buying a wall-hung boiler, the merchant will give a water pressure range, you must control it, if the water pressure is too low, you can buy a circulating pump to maintain the water pressure.

    2. If the motherboard or igniter is damaged, you must contact the after-sales service for door-to-door inspection and maintenance, this ordinary person can't do it, because it is very dangerous, and if you destroy other parts, the whole machine will no longer be able to work, and professional things must be done by professional people. 3. Pay attention to ventilation when using it, and the whole flue must be cleaned frequently. Nowadays, most of them are biaxial flues, and poor ventilation is a very big problem.

    As long as hygiene is done well, most problems will not occur. 4. Forget to open the gas valve, this is still very simple. You can take the initiative to open, if you can't open it, you can also contact the **business to help you open it.

  8. Anonymous users2024-02-04

    1. The smoke pipe cannot be exhausted normally, resulting in the wall-hung boiler being unable to operate normally. 2. The gas pipeline is blocked. 3. There is carbon deposition inside the wall-hung boiler. 4. The water pressure at home is too low or the water pressure of the equipment is too low.

    It is recommended to deal with the blind formula:

    1. When using the wall-hung boiler at ordinary times, it is necessary to clean the smoke pipe regularly, generally speaking, the smoke pipe will be often blocked due to time, and only need to clean it to resume operation.

    2. It is very dangerous for the gas pipeline to be blocked, first of all, it is necessary to check whether the pipeline is damaged regularly, if there is a new network in time, and if the gas inside the pipeline is insufficient, it is necessary to recharge it in time.

    3. The wall-hung boiler will be used for a long time to make the carbon deposition phenomenon become very serious, at this time it is absolutely not ignited, if these problems occur, we must contact the after-sales department, let the professional master come to repair, do not disassemble the internal parts of the machine without permission, it is very dangerous, in addition, if you damage other parts, it will make the wall-hung boiler further damaged.

    4. Check whether the water pressure is normal, if it is not normal, you must buy a circulating pump to increase the water pressure, and if the water pressure of the equipment is too low, then you must first maintain the blood pressure of the equipment up and down, as long as it is normal, you can generally return to normal use.

Related questions
10 answers2024-05-20

1. Power selection: The selection of wall-hung boiler should be based on many factors such as the area where your house is located (different climatic conditions in different regions), location, house area, enclosure structure (villas, bungalows, energy-saving buildings, old buildings, etc.), floor height, floor, unit, heating terminal heat dissipation type (floor heating, radiator, fan coil unit is the most common) and many other factors. >>>More

14 answers2024-05-20

Advantages of wall-hung boiler heating.

1.The advantage of Anerrui wall-hung boiler heating is that it is energy-saving and environmentally friendly, because it does not waste a lot of heat on the pipeline like central heating. Comparatively speaking, wall-hung boiler heating improves heating efficiency. >>>More

12 answers2024-05-20

1.The difference between condensing wall-hung boiler and ordinary wall-hung boiler - comparison of energy saving: >>>More

3 answers2024-05-20

What brand of wall-hung boiler is good, the top ten brands of wall-hung boiler ranking recommend the top ten brands One of the top ten brands of wall-hung boiler: Beretta wall-hung boiler Beretta wall-hung boiler is a brand of Italian Riello Co., Ltd., founded in 1973. It is one of the largest heating equipment manufacturers in Italy and a major supplier in the field of mining in China. >>>More

8 answers2024-05-20

1. Connect the power supply to the wall-hung boiler.

2. Turn on the wall-hung boiler, some wall-hung boilers will have a switch. >>>More