The insulation resistance of the submersible pump, the absolute resistance of the submersible pump i

Updated on society 2024-05-22
6 answers
  1. Anonymous users2024-02-11

    What do you want to know?

    Insulation resistance of submersible pumps: including the resistance to the ground of each phase of three phases, the normal is 300 megaohms to infinity. The phase-to-phase resistance of two pairs of three phases is normally 300 megaohms to infinity. Detect with a shake table.

    The resistance of U, V, and W, the value of the three-phase resistance should be roughly equal, if the three-phase is unbalanced, it means that there is a problem with the motor. This is detected with a multimeter or digital bridge.

  2. Anonymous users2024-02-10

    The insulation resistance of the submersible pump should be greater than 50 megaohms in the cold state.

  3. Anonymous users2024-02-09

    Summary. How much is the absolute image resistance of the submersible pump to be considered normal, hello dear, the absolute image resistance of the submersible pump is greater than the normal insulation resistance is not less than. If it is a new installation or overhaul, the insulation resistance of the low-pressure water pump should not be lower, and the operating one should not be less than 1000 per volt; If it is a high-pressure water pump, its insulation resistance should not be less than 1m per kilovolt operation

    The insulation resistance of the submersible pump plays a role in protecting the motor for the submersible pump, which is to test the insulation between the motor rotor and the motor shell, if the insulation is unqualified, the motor is easy to enter the water, leakage, and cause damage to the motor: the wire is short-circuited, the motor can not work, so that the submersible pump can not run, and it is easy to cause injury to people. The structure of the motor part of the submersible pump has an effect on the insulation.

    The sealing situation has an impact on the working efficiency of the submersible pump. The insulation resistance of the submersible pump is the withstand voltage level of the magnet wire, and the commonly used ones are 750V, 1000V, 4000V, 6000V, and 10KV. The test standards for insulation resistance values are as follows:

    1. The insulation resistance of low-voltage electrical equipment after new installation or overhaul should not be less than. 2. The requirements of the line in operation can be reduced to no less than 1000 per volt. 3. The insulation resistance of the three-phase squirrel cage asynchronous motor shall not be less than the stator insulation resistance value of the three-phase wound asynchronous motor, the hot state shall be greater than that of the cold state, and the rotor insulation resistance value shall be greater than that of the cold state.

    How much is the absolute image resistance of the submersible pump to be considered normal, hello dear, the absolute image resistance of the submersible pump is greater than the normal insulation resistance is not less than. If it is a new installation or overhaul, the insulation resistance of the low-pressure water pump should not be lower, and the operating one should not be less than 1000 per volt; If it is a high-pressure water pump, its insulation resistance should not be less than 1m per kilovolt operationThe insulation resistance of the submersible pump plays a role in protecting the motor for the submersible pump, which is to test the insulation between the motor rotor and the motor housing, if the insulation is unqualified, the motor is easy to enter the water, leakage, and cause damage to the motor

    The wire is short-circuited, and the motor cannot work, which makes the submersible pump unable to operate, and it is easy to cause injury to people. The structure of the motor part of the submersible pump has an effect on the insulation. The sealing situation has an impact on the working efficiency of the submersible pump.

    The insulation resistance of the submersible pump is the withstand voltage level of the magnet wire, and the commonly used ones are 750V, 1000V, 4000V, 6000V, and 10KV. The test standards for the insulation resistance value are as follows: 1. The insulation resistance of the newly installed or overhauled low-voltage electrical equipment should not be less than.

    2. The requirements of the line in operation can be reduced to no less than 1000 per volt. 3. The insulation resistance of the three-phase squirrel cage asynchronous motor shall not be less than the stator insulation resistance value of the three-phase wound asynchronous motor, the hot state shall be greater than that of the cold state, and the rotor insulation resistance value shall be greater than that of the cold state.

    I measured with a multimeter.

    Hello dear, the insulation resistance of the submersible pump: including the resistance to the ground of each phase of the three phases, the normal is 300 megaohms to infinity.

  4. Anonymous users2024-02-08

    Summary. 380v submersible pump resistance how much pro, hello, glad your question. 1. Description of the resistance value of the submersible pump coil:

    The resistance value of the pump coil of the same power is not the same according to other parameters, so this can not be confirmed, and it needs to be measured according to the actual situation, generally the following points affect the type of pump coil resistance pump, such as sewage pump, submersible pump, vertical or horizontal booster pump, etc.; The power supply voltage of the water pump, such as single-phase or three-phase water pump, 220V, 380V and 440V and other factors; The rated speed of the same power water pump, the rated speed of the water pump is different, then the coil resistance value is also different; The material of the pump coil, such as aluminum coil or copper coil, is different, and the resistance value will definitely not be the same. Second, the coil resistance calculation also depends on the voltage of the pump, if the voltage of the pump is three-phase 380V, the formula: p=u r, then r=u p=380 4000=ohms.

    380v submersible pump resistance how much pro, hello, glad your question. 1. Judgment and description of the resistance value of the submersible pump coil: the resistance value of the pump coil of the same power is different according to other parameters, so this cannot be confirmed, and it needs to be measured according to the actual situation, and generally the following points affect the type of pump coil resistance pump, such as sewage pump, submersible pump, vertical or horizontal booster pump, etc.; The power supply voltage of the water pump, such as single-phase or three-phase water pump, 220V, 380V and 440V and other factors; The rated speed of the same power water pump, the rated speed of the water pump is different, then the coil resistance value is also different; The material of the pump coil, such as aluminum coil or copper coil, is different, and the resistance value will definitely not be the same.

    Second, the coil resistance meter wheel is delayed to see the voltage of the pump, if the voltage of the pump is three-phase 380V, the formula: P=U R, then R=U P=380 4000=Ohm.

    Yes, dear. Why don't you go back.

    Dear, yes. Are the three-phase resistance values all positive length motors?

    The relative ground resistance of 380V three-phase motor is generally not less than megaohm, and the relative ground resistance of 6kV three-phase motor is not less than 6 megaohm. For the rated voltage of 380V motor, use 500V or 1000V shake meter (megohmmeter) to measure to the ground, greater than is considered normal (the bigger the better). The insulation resistance of the 6kV motor should be measured by 1000V-2500V shake meter, and its value should not be less than 6m.

    380V electric or clever or motive use a 500V shake meter to measure the insulation resistance, and its value should not be lower.

    The resistance value measured by the multimeter is all.

    Dear, it's okay, it's normal.

  5. Anonymous users2024-02-07

    Summary. Dear, I am glad to answer for you: how much is the absolute image resistance of the submersible pump is considered normal, if it is a new installation or overhauled low-pressure water pump insulation resistance should not be lower, is running should not be less than 1000 per volt working voltage Submersible pump is an important equipment for deep well water lifting.

    When in use, the whole unit dives into the water to work, extracting groundwater to the surface, which is domestic water, mine rescue, industrial cooling, farmland irrigation, seawater lifting, ship loading, and can also be used for fountain landscape.

    Dear, I am glad to answer for you: how much is the absolute image resistance of the submersible pump is considered normal, if it is a new installation or overhauled low-pressure water pump insulation resistance should not be lower, is running should not be less than 1000 per volt working voltage Submersible pump is an important equipment for deep well water lifting. When in use, the whole unit dives into the water to work, and takes the underground disturbance water to the surface, which is domestic water, mine wide mountain rescue, industrial cooling, farmland irrigation, seawater lifting, ship loading, and can also be used for fountain landscape.

    I used a caliper meter to measure how much resistance is normal.

    Normal is 300 megaohms to infinity.

  6. Anonymous users2024-02-06

    Hello, I am glad to serve you and give you the following answers: large submersible pumps can have thermal resistance, which is mainly used to protect the operating state of the motor and submersible pump and prevent burnout and damage caused by excessive load. When the submersible pump fails, the thermal resistance will play a certain protective role, which can quickly disconnect the power supply of the submersible pump and prevent overload from burning out the motor.

    Workaround:1Check whether the power supply voltage is normal, if the voltage is too low, it may cause the motor to be overloaded and malfunction, and measures should be taken to adjust the power supply voltage; 2.

    Check whether the submersible pump has carbon deposits, and if so, it should be cleaned in time; 3.Check whether the thermal resistance is faulty, and if there is a fault, it should be replaced in time; 4.Check whether the motor of the submersible pump is faulty, and if there is a fault, the finger should be replaced in time.

    Related knowledge: RTD is an electronic component, its function is to change the resistance value to the current value within a certain temperature range, so as to control the load of the motor and prevent overload from burning out the motor. It is divided into horizontal RTD and vertical RTD, and their main difference is that the resistance value of horizontal RTD changes with the change of temperature, while the resistance value of the vertical RTD does not change with the change of temperature.

Related questions
6 answers2024-05-22

The difference between sewage pump and submersible pump is mainly reflected in the following three aspects: >>>More

5 answers2024-05-22

Submersible pump head calculation method: The effective energy obtained by the unit weight of liquid after flowing through the pump. It is an important working performance parameter of the pump, also known as the pressure head. >>>More

8 answers2024-05-22

BQS Mine Explosion-proof Sand Discharge Pump, full name of "BQS Mine Flameproof Sewage Discharge and Sand Discharge Submersible Pump", is a new generation of mine flameproof drainage equipment developed to meet the drainage needs of underground coal mining faces and dangerous places containing methane or coal dust in the air, and to adapt to the final development direction of mine drainage diving and automation. The pump is a new type of multi-purpose mining submersible pump innovatively designed on the basis of the existing sand discharge pump structure, and the implementation standard is MT 671-2005 gb3836 201. >>>More

10 answers2024-05-22

Mining submersible pumps are mainly used for the drainage of the first pump room of the coal mine, the rescue drainage or the re-mining drainage after the flooding disaster of the coal mine, and the centrifugal pump is commonly used. When using the mining submersible pump, it is necessary to avoid frequently opening and closing the mining submersible pump. >>>More

7 answers2024-05-22

Simple calculation: power*2=current; Each square copper wire has 3-6 currents (according to the length of the wire, the heat dissipation is good or bad). >>>More